Noninvasive automated assessment of the ratio of pulmonary to systemic flow in atrial septal defects by spatio-temporal integration of Doppler velocity profile

被引:0
|
作者
Hozumi, T [1 ]
Yoshida, K [1 ]
Ueda, Y [1 ]
Akasaka, T [1 ]
Takagi, T [1 ]
Kaji, S [1 ]
Kawamoto, T [1 ]
Morioka, S [1 ]
机构
[1] Kobe Gen Hosp, Kobe, Hyogo, Japan
关键词
D O I
10.1016/S0735-1097(97)84784-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:248A / 248A
页数:1
相关论文
共 38 条
  • [1] Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method
    Ueda, Y
    Hozumi, T
    Yoshida, K
    Watanabe, H
    Akasaka, T
    Takagi, T
    Yamamuro, A
    Homma, S
    Yoshikawa, J
    HEART, 2002, 88 (03) : 278 - 282
  • [2] NONINVASIVE ASSESSMENT OF PULMONARY TO SYSTEMIC FLOW AND RESISTANCE RATIOS IN VENTRICULAR SEPTAL-DEFECTS BY DOPPLER ECHOCARDIOGRAPHY
    RUPPRECHT, T
    DEEG, KH
    HOFBECK, M
    RICHTER, K
    SINGER, H
    ULTRASCHALL IN DER MEDIZIN, 1989, 10 (02): : 83 - 89
  • [3] Noninvasive automated assessment of left atrial-to-right atrial shunt flow volume in patients with atrial septal defect by digital color Doppler velocity integration method
    Hozumi, T
    Akasaka, T
    Mori, I
    Yamamuro, A
    Kanaki, Y
    Yoshikawa, J
    CIRCULATION, 1999, 100 (18) : 572 - 572
  • [4] Noninvasive Assessment of Spatio-Temporal Recurrence in Atrial Fibrillation
    Bonizzi, Pietro
    Zeemering, Stef
    van Rosmalen, Frank
    Schotten, Ulrich
    Karel, Joel
    28TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2020), 2021, : 900 - 904
  • [5] Effect of frame rate, color gain, and filter setting on automated cardiac output measurement by spatio-temporal integration of Doppler velocity profile in vivo
    Hozumi, T
    Yoshida, K
    Akasaka, T
    Takaji, T
    Kaji, S
    Kawamoto, T
    Yagi, T
    Morioka, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 43A - 43A
  • [6] DOPPLER-ECHOCARDIOGRAPHIC MEASUREMENT OF THE RATIO OF PULMONARY SYSTEMIC FLOW-RATES IN ATRIAL SEPTAL-DEFECTS - BASED UPON 15 CASES
    VANZETTO, G
    ROSSIGNOL, AM
    HADJIAN, O
    BORREL, E
    CONTARD, M
    MACHECOURT, J
    DENIS, B
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1992, 41 (05): : 287 - 294
  • [7] ACCURACY OF DOPPLER ECHOCARDIOGRAPHIC ESTIMATES OF PULMONARY-TO-SYSTEMIC FLOW RATIOS IN PATIENTS WITH ATRIAL SEPTAL-DEFECTS
    VITARELLI, A
    CARDAMONE, S
    SCAPATO, A
    DECURTIS, G
    CLINICAL RESEARCH, 1986, 34 (02): : A351 - A351
  • [8] FLOW VELOCITY PATTERNS ACROSS ATRIAL SEPTAL-DEFECTS RECORDED WITH DOPPLER ECHOCARDIOGRAPHY
    HATLE, L
    ACTA PAEDIATRICA SCANDINAVICA, 1986, : 68 - 77
  • [9] NONINVASIVE ASSESSMENT OF HEMODYNAMIC PARAMETERS AND ASSOCIATED CARDIAC DEFECTS IN ATRIAL SEPTAL-DEFECTS BY DOPPLER-ECHOCARDIOGRAPHY
    RUPPRECHT, T
    SEILER, T
    HOFBECK, M
    WILD, F
    SINGER, H
    ULTRASCHALL IN DER MEDIZIN, 1994, 15 (02): : 89 - 94
  • [10] NON-INVASIVE EVALUATION OF THE RATIO OF PULMONARY TO SYSTEMIC FLOW IN ATRIAL SEPTAL-DEFECT BY DUPLEX DOPPLER ECHOCARDIOGRAPHY
    KITABATAKE, A
    INOUE, M
    ASAO, M
    ITO, H
    MASUYAMA, T
    TANOUCHI, J
    MORITA, T
    HORI, M
    YOSHIMA, H
    OHNISHI, K
    ABE, H
    CIRCULATION, 1984, 69 (01) : 73 - 79