Effect of refrigerant charge on the performance of air-conditioning systems

被引:0
|
作者
Goswami, DY [1 ]
Ek, G [1 ]
Leung, M [1 ]
Jotshi, CK [1 ]
Sherif, SA [1 ]
Colacino, F [1 ]
机构
[1] Univ Florida, Dept Mech Engn, Gainesville, FL 32611 USA
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
An air-conditioning system operates in an optimal condition if the system is fully charged with specified amount of refrigerant. Poor field maintenance or refrigerant leakage causes low level of charge resulting in a lower thermal performance and higher operating cost. An experimental investigation was conducted to study the effect of low charge level of R-22 on the performance of a 3-ton residential air-conditioning system. The experimental results show that if a system is undercharged to 90%, the effect is small, 3.5% reduction in cooling capacity and 2% increase in COP. However, the system performance suffers serious degradation if the level of charge drops below 80%. An ice layer formed on the outer cooling coil surface impedes the heat transfer between the warm air and cold refrigerant vapor. An economic analysis shows that the cost of properly charging a system which has otherwise gone down to 85% charge level can pay for itself in savings in a short period of 3 to 4 months.
引用
收藏
页码:1635 / 1640
页数:6
相关论文
共 50 条
  • [1] Effect of refrigerant charge on the performance of air conditioning systems
    Goswami, DY
    Ek, G
    Leung, M
    Jotshi, CK
    Sherif, SA
    Colacino, F
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (08) : 741 - 750
  • [2] Experimental evaluation of refrigerant mass charge and ambient air temperature effects on performance of air-conditioning systems
    Deymi-Dashtebayaz, Mahdi
    Farahnak, Mehdi
    Moraffa, Mojtaba
    Ghalami, Arash
    Mohammadi, Nima
    [J]. HEAT AND MASS TRANSFER, 2018, 54 (03) : 803 - 812
  • [3] Experimental evaluation of refrigerant mass charge and ambient air temperature effects on performance of air-conditioning systems
    Mahdi Deymi-Dashtebayaz
    Mehdi Farahnak
    Mojtaba Moraffa
    Arash Ghalami
    Nima Mohammadi
    [J]. Heat and Mass Transfer, 2018, 54 : 803 - 812
  • [4] A refrigerant charge fault detection method for variable refrigerant flow (VRF) air-conditioning systems
    Liu, Jiangyan
    Hu, Yunpeng
    Chen, Huanxin
    Wang, Jiangyu
    Li, Guannan
    Hu, Wenju
    [J]. APPLIED THERMAL ENGINEERING, 2016, 107 : 284 - 293
  • [5] The performance of an air-conditioning system with the refrigerating circle using air as refrigerant
    Chen, Y
    Xie, GZ
    Wu, YZ
    [J]. 2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 499 - 505
  • [6] Comparative performance of air-conditioning systems with different refrigerant circuitries in liquid-separation condenser
    Chen, Jianyong
    Li, Yunhai
    Ding, Rong
    Lin, Xu
    Chen, Ying
    Luo, Xianglong
    Yang, Zhi
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 92 : 154 - 164
  • [7] A review of recent advancements of variable refrigerant flow air-conditioning systems
    Wan, Hanlong
    Cao, Tao
    Hwang, Yunho
    Oh, Saikee
    [J]. APPLIED THERMAL ENGINEERING, 2020, 169
  • [8] Energy Studies on Central and Variable Refrigerant Flow Air-Conditioning Systems
    Abdullah, H.
    Nitamakwuavan, S.
    Jalaludin, A. F.
    [J]. 4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 486 - 490
  • [9] Monitoring hydrofluorocarbon refrigerant leakage from air-conditioning systems in buildings
    Cheong, KW
    Riffat, SB
    [J]. APPLIED ENERGY, 1996, 53 (04) : 341 - 347
  • [10] AIR-CONDITIONING SYSTEMS WITH A BACTERIOSTATIC EFFECT
    VANBAARLE, AJ
    [J]. ANTONIE VAN LEEUWENHOEK JOURNAL OF MICROBIOLOGY, 1980, 46 (05): : 504 - 504