Quantification of Low Amounts of Zoledronic Acid by HPLC-ESI-MS Analysis: Method Development and Validation

被引:2
|
作者
Petrovici, Anca-Roxana [1 ]
Silion, Mihaela [2 ]
Simionescu, Natalia [1 ]
Kallala, Rami [3 ]
Pinteala, Mariana [1 ]
Maier, Stelian S. [1 ,4 ]
机构
[1] Petru Poni Inst Macromol Chem, Ctr Adv Res Bionanoconjugates & Biopolymers, 41A Grigore Ghica Voda Alley, Iasi 700487, Romania
[2] Petru Poni Inst Macromol Chem, Phys Polymers & Polymer Mat Dept, 41A Grigore Ghica Voda Alley, Iasi 700487, Romania
[3] Corthotec Ltd, 130 Wood St, London EC2V 6DL, England
[4] Gheorghe Asachi Tech Univ Iasi, Polymers Res Ctr, 73 Dimitrie Mangeron Blvd, Iasi 700050, Romania
关键词
zoledronic acid (ZA); calcium sulfate hemihydrate; solid inorganic matrix; HPLC-ESI-MS analysis; extracted ion chromatogram (EIC); ZA-calcium complexes; method development and validation; IN-VITRO; HYDROXYAPATITE; BONE; BISPHOSPHONATE; OSTEOPOROSIS; CALCIUM; PHARMACEUTICALS; PLASMA;
D O I
10.3390/ijms23115944
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Zoledronic acid (ZA) is used in the treatment of various bone pathologies, but it forms complexes with calcium ions present in body fluids, decreasing ZA bioavailability. Thereby, the study first describes the identification of ZA-calcium complexes that form in calcium-rich environments, in order to establish the bioavailable ZA concentration. Then, a new method for quantification of low ZA amounts in milieus that mimics in vivo conditions by using simulated body fluid and calcium sulfate hemihydrate was described. Almost all analytical methods of ZA quantification described in the literature require compound derivatization. At very low concentrations, derivatization is prone to analyte loss, therefore compromising the analytical results. In our study, we avoided ZA derivatization by using a high-performance liquid chromatography and electrospray ionization mass spectrometry (HPLC-ESI-MS) system, conducting the investigation based on the fragmentation mass extracted ion chromatograms specific to the ZA protonated form. The method was validated by selectivity, precision, accuracy, linearity, signal to noise ratio, and limit of detection and limit of quantification calculation. Experimentally, this method can detect ranges of 0.1-0.5 ng/mL and precisely quantify ZA concentrations as low as 0.1 ng/mL. This method could provide the basis for quantifying low amounts of ZA in the blood during long-term administration.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Analysis of Homoisoflavonoids in Caesalpinia digyna by HPLC-ESI-MS, HPLC and Method Validation
    Roy, Somendu K.
    Srivastava, Amit
    Jachak, Sanjay M.
    NATURAL PRODUCT COMMUNICATIONS, 2012, 7 (09) : 1189 - 1192
  • [2] Validation and Application of HPLC-ESI-MS/MS Method for the Determination of Irsogladine
    Hoang, N. H.
    Huong, N. L.
    Hong, S. -Y.
    Park, Je Won
    ACTA CHROMATOGRAPHICA, 2017, 29 (04) : 459 - 462
  • [3] Development and validation of a specific and sensitive HPLC-ESI-MS method for quantification of lysophosphatidylinositols and evaluation of their levels in mice tissues
    Masquelier, Julien
    Muccioli, Giulio G.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 126 : 132 - 140
  • [4] Development and validation of a selective HPLC-ESI-MS/MS method for the quantification of glyoxal and methylglyoxal in atmospheric aerosols (PM2.5)
    Kampf, Christopher J.
    Bonn, Boris
    Hoffmann, Thorsten
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (10) : 3115 - 3124
  • [5] Development and validation of a selective HPLC-ESI-MS/MS method for the quantification of glyoxal and methylglyoxal in atmospheric aerosols (PM2.5)
    Christopher J. Kampf
    Boris Bonn
    Thorsten Hoffmann
    Analytical and Bioanalytical Chemistry, 2011, 401 : 3115 - 3124
  • [6] Development and validation of a sensitive HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma
    Roda, Aldo
    Sabatini, Laura
    Barbieri, Anna
    Guardigli, Massimo
    Locatelli, Marcello
    Saverio Violante, Francesco
    Rovati, Lucio C.
    Persiani, Stefano
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 119 - 126
  • [7] HPLC-ESI-MS/MS validation and pharmacokinetics of kalopanaxsaponin A in rats
    Qiu, Feng
    Zhao, Xiaoping
    Lu, Xuran
    Wang, Manyuan
    Gong, Muxin
    RSC ADVANCES, 2015, 5 (10): : 7260 - 7266
  • [8] Analysis of Perchlorate and Oxyhalides by HPLC-ESI-MS
    Ito, Kanna
    LC GC NORTH AMERICA, 2013, : 17 - 17
  • [9] Regioisomer-independent quantification of fatty acid oxidation products by HPLC-ESI-MS/MS analysis of sodium adducts
    Katelyn W. Ahern
    Vlad Serbulea
    Catherine L. Wingrove
    Zachary T. Palas
    Norbert Leitinger
    Thurl E. Harris
    Scientific Reports, 9
  • [10] Regioisomer-independent quantification of fatty acid oxidation products by HPLC-ESI-MS/MS analysis of sodium adducts
    Ahern, Katelyn W.
    Serbulea, Vlad
    Wingrove, Catherine L.
    Palas, Zachary T.
    Leitinger, Norbert
    Harris, Thurl E.
    SCIENTIFIC REPORTS, 2019, 9 (1) : 11197