Continuous-flow/stopped-flow system using an immunobiosensor for quantification of human serum IgG antibodies to Helicobacter pylori

被引:17
|
作者
Messina, GA [1 ]
Torriero, AA [1 ]
De Vito, IE [1 ]
Olsina, RA [1 ]
Raba, J [1 ]
机构
[1] Natl Univ San Luis, Dept Chem, RA-5700 San Luis, Argentina
关键词
ELISA; Helicobacter pylori; amperometric immunoreactor; horseradish peroxidase; hydroquinone; FIA;
D O I
10.1016/j.ab.2004.07.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conventional methods, such as gastric biopsy, enzyme-linked immunosorbent assay (ELISA), culture, require a long time for the determination of Helicobacter pylori infections. This study reports an amperometric immunoreactor for rapid and sensitive quantification of human serum immunoglobulin G (IgG) antibodies to H. pylori. Antibodies in the serum sample are allowed to react immunologically with the purified H. pylori antigens that are immobilized on a rotating disk. The bound antibodies are quantified by horseradish peroxidase (HRP) enzyme-labeled second antibodies specific to human IgG. HRP in the presence of hydrogen peroxide catalyzes the oxidation of hydroquinone to p-benzoquinone. The electrochemical reduction back to hydroquinone is detected on a glassy carbon electrode surface at -0.15 V. The electrochemical detection can be done within 1 min, and the analysis time does not exceed 30 min. The calculated detection limits for amperometric detection and the ELISA procedure are 0.6 and 1.9 U ml(-1), respectively. The amperometric immunoreactors showed higher sensitivity and lower time consumed than did the standard spectrophotometric detection ELISA method. It can also be used for rapid analysis in conventional and field conditions in biological, physiological, and analytical practices. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 50 条
  • [1] A STOPPED-FLOW CONTINUOUS-FLOW METHOD FOR KINETIC DETERMINATIONS
    HSIEH, YS
    CROUCH, SR
    ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 277 - 282
  • [2] Continuous-flow/stopped-flow system for determination of ascorbic acid using an enzymatic rotating bioreactor
    Messina, GA
    Torriero, AAJ
    De Vito, IE
    Raba, J
    TALANTA, 2004, 64 (04) : 1009 - 1017
  • [3] Continuous-flow/stopped-flow system for enzyme immunoassay using a rotating bioreactor: determination of Chagas disease
    Salinas, E
    Torriero, AAJ
    Battaglini, F
    Sanz, MI
    Olsina, R
    Raba, J
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (02): : 313 - 321
  • [4] Continuous-flow/stopped-flow system incorporating a rotating bioreactor for the determination of penicillins in pharmaceutical products
    Lapierre, AV
    Olsina, RA
    Raba, J
    ANALYTICA CHIMICA ACTA, 1999, 396 (2-3) : 143 - 149
  • [5] Zearalenone determination in corn silage samples using an immunosensor in a continuous-flow/stopped-flow systems
    Panini, Nancy V.
    Bertolino, Franco A.
    Salinas, Eloy
    Messina, German A.
    Raba, Julio
    BIOCHEMICAL ENGINEERING JOURNAL, 2010, 51 (1-2) : 7 - 13
  • [6] STOPPED-FLOW, AIR-SEGMENTED CONTINUOUS-FLOW - KINETIC DETERMINATIONS OF GLUCOSE AND PHOSPHATE IN WINE AND SERUM SAMPLES
    HSIEH, YS
    CROUCH, SR
    ANALYTICA CHIMICA ACTA, 1993, 284 (01) : 159 - 166
  • [8] CONTINUOUS-FLOW STOPPED-FLOW SYSTEM INCORPORATING 2 NOTATING BIOREACTORS IN TANDEM - APPLICATION TO THE DETERMINATION OF ALKALINE-PHOSPHATASE ACTIVITY IN SERUM
    RABA, J
    MOTTOLA, HA
    ANALYTICAL CHEMISTRY, 1994, 66 (09) : 1485 - 1489
  • [9] Integrated microfluidic magnetic immunosensor for quantification of human serum IgG antibodies to Helicobacter pylori
    Pereira, Sirley V.
    Messina, German A.
    Raba, Julio
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02): : 253 - 257
  • [10] Screen-printed immunosensor for quantification of human serum IgG antibodies to Helicobacter pylori
    Messina, German A.
    De Vito, Irma E.
    Raba, Julio
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 128 (01) : 23 - 30