Ability of humans to smell geosmin, 2-MIB and nonadienal in indoor air when using contaminated drinking water

被引:20
|
作者
Omur-Ozbek, P. [1 ]
Little, J. C. [1 ]
Dietrich, A. M. [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
关键词
drinking water; geosmin; Henry's Law; indoor air concentration; 2-methylisoborneol; nonadienal; odour threshold;
D O I
10.2166/wst.2007.186
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The most common compounds responsible for off flavours are geosmin, 2-MIB, and nonadienal which are poorly removed by conventional water treatment operations and hence result in customer complaints. Because these odourants are moderately volatile and have very low odour threshold values, it is necessary to determine their concentrations in air when water is used indoors. If the detectable aqueous concentrations for these odourants are known, the utilities may take action to treat their water at times when the concentration of the raw water exceeds the threshold concentration. To predict the concentration in the shower stall and bathroom air after showering, recently published Henry's law constants for the selected odourants and a model developed to determine the volatilization of the odourous compounds by applying two-resistance theory were used. Then the results were compared with the odour threshold concentration data to determine under which conditions the odourants become detectable. For parameters representing a typical bathroom and shower stall setting, the results showed that the odourants become detectable when the aqueous concentration of geosmin and nonadienal exceed 10 ng/L at 42 degrees C. As the aqueous concentration increases, geosmin and nonadienal become detectable at lower temperatures, however 2-MIB is only detectable above 20 ng/L and at 42 degrees C.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 8 条
  • [1] Effect of residual chlorine on the analysis of geosmin, 2-MIB and MTBE in drinking water using the SPME technique
    Lin, TF
    Liu, CL
    Yang, FC
    Hung, HW
    WATER RESEARCH, 2003, 37 (01) : 21 - 26
  • [2] Geosmin and 2-MIB Removal by Full-Scale Drinking Water Treatment Processes in the Republic of Korea
    Kim, Keug Tae
    Park, Yong-Gyun
    WATER, 2021, 13 (05)
  • [3] Removal of geosmin and 2-methylisoboneol (2-MIB) by membrane system combined with powdered activated carbon (PAC) for drinking water treatment
    Kim, Chansik
    Lee, Sueng Ii
    Hwang, Suhyun
    Cho, Myoungsu
    Kim, Han-Seung
    Noh, Soo Hong
    JOURNAL OF WATER PROCESS ENGINEERING, 2014, 4 : 91 - 98
  • [4] Removal of geosmin and 2-methylisorboneol (2-MIB) in water from Zuikerbosch Treatment Plant (Rand Water) using β-cyclodextrin polyurethanes
    Mamba, B. B.
    Krause, R. W.
    Malefetse, T. J.
    Mhlanga, S. D.
    Sithole, S. P.
    Salipira, K. L.
    Nxumalo, E. N.
    WATER SA, 2007, 33 (02) : 223 - 227
  • [5] Quantitative PCR based detection system for cyanobacterial geosmin/2-methylisoborneol (2-MIB) events in drinking water sources: Current status and challenges
    Devi, Apramita
    Chiu, Yi-Ting
    Hsueh, Hsin-Ta
    Lin, Tsair-Fuh
    WATER RESEARCH, 2021, 188
  • [6] Quantitative method to determine the regional drinking water odorant regulation goals based on odor sensitivity distribution:Illustrated using 2-MIB
    Jianwei Yu
    Wei An
    Nan Cao
    Min Yang
    Junong Gu
    Dong Zhang
    Ning Lu
    Journal of Environmental Sciences, 2014, 26 (07) : 1389 - 1394
  • [7] Quantitative method to determine the regional drinking water odorant regulation goals based on odor sensitivity distribution: Illustrated using 2-MIB
    Yu, Jianwei
    An, Wei
    Cao, Nan
    Yang, Min
    Gu, Junong
    Zhang, Dong
    Lu, Ning
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2014, 26 (07) : 1389 - 1394
  • [8] Comparison of two selective methods for determination of geosmin (1,2,7,7-tetramethyl-2-norborneol) and 2-MIB (2-methylisoborneol) in drinking and raw water samples by capillary gas chromatography-mass spectrometry
    Sibali, Linda Lunga
    Schoeman, Carl
    Morobi, Jabulile Selina
    Molalatladi, Barnard Saenet
    WATER QUALITY RESEARCH JOURNAL OF CANADA, 2010, 45 (04): : 491 - 497