Ion chromatographic determination of trace anions and cations in high-purity water

被引:0
|
作者
Nguyen, VD
机构
[1] Institute of Applied Physical, Chemistry, Research Centre Julich, 52425 Julich, Germany
来源
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion chromatographic measuring system for the off-line and on-line determination of some trace anions and cations in high-purity water is presented. The ng/L level of anions and cations in 20-130 mL high-purity water can be analyzed after preconcentration on ion exchange columns. The concentrated solutes are eluted by eluents from the trap column and separated using a Dionex analytical column. The quantification of each ion is achieved using the suppressor technique and conductivity detector. The influence of Various parameters on the results is discussed. The detection limits of cations and anions are between 10 and 30 ng/L for chloride, bromide, nitrate, phosphate, sulphate, sodium, ammonium, potassium, magnesium and calcium ions.
引用
收藏
页码:738 / 741
页数:4
相关论文
共 50 条
  • [1] DETERMINATION OF ANIONS IN HIGH-PURITY WATER BY ION CHROMATOGRAPHY
    TRETTER, H
    PAUL, G
    BLUM, F
    SCHRECK, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 321 (07): : 650 - 652
  • [2] Ion Chromatographic Determination of Cations and Anions in Tap Water
    Liu, Dongwu
    Chen, Zhiwei
    Xu, Lei
    Zhang, Zhengjie
    Ju, Baoyu
    Cheng, Wenchao
    ADVANCED RESEARCH ON AUTOMATION, COMMUNICATION, ARCHITECTONICS AND MATERIALS, PTS 1 AND 2, 2011, 225-226 (1-2): : 128 - +
  • [3] ELECTROOSMOTIC PRECONCENTRATION OF CATIONS AND ANIONS FOR THE ANALYSIS OF HIGH-PURITY WATER
    MOSKVIN, LN
    GURSKII, VS
    EPIMAKHOVA, LV
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (07) : 929 - 931
  • [4] Ion-chromatographic determination of fluoride and chloride ions in high-purity water
    Moskvin, LN
    Katruzov, AN
    Nikitina, TG
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (02) : 173 - 177
  • [5] Determination of trace-level anions in high-purity water samples by ion chromatography with an automated on-line fluent generation system
    Liu, Y
    Kaiser, E
    Avdalovic, N
    MICROCHEMICAL JOURNAL, 1999, 62 (01) : 164 - 173
  • [6] RECENT ADVANCES IN THE SIMULTANEOUS DETERMINATION OF ANIONS AND SILICA IN HIGH-PURITY WATER
    HARVEY, S
    JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2): : 209 - 220
  • [7] Determination of trace metallic impurities in high-purity quartz by ion chromatography
    Dash, K
    Chandrasekaran, K
    Thangavel, S
    Dhaville, SM
    Arunachalam, J
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) : 25 - 31
  • [8] DETERMINATION OF TRACE COBALT IN HIGH-PURITY NICKEL
    FLASCHKA, H
    SPEIGHTS, RM
    MICROCHEMICAL JOURNAL, 1969, 14 (03) : 490 - &
  • [9] DETERMINATION OF TRACE IMPURITIES IN HIGH-PURITY SELENIUM
    WILLIAMS, AI
    ANALYST, 1961, 86 (102) : 172 - &
  • [10] Simple procedure for ion chromatographic determination of anions and cations at trace levels in ice core samples
    Jauhiainen, T
    Moore, J
    Perämäki, P
    Derome, J
    Derome, K
    ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) : 21 - 29