Floating microelectrode arrays chronically implanted into the feline peripheral nerve elicit a characteristic tissue response

被引:0
|
作者
Kolarcik, Christi L. [1 ]
Puglisi, Kelly [1 ]
Lesniak, Andrew [1 ]
Demetris, Anthony J. [1 ]
Fisher, Lee E. [1 ]
Gaunt, Robert A. [1 ]
机构
[1] Univ Pittsburgh, Pittsburgh, PA USA
来源
FASEB JOURNAL | 2017年 / 31卷
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
659.1
引用
收藏
页数:1
相关论文
共 37 条
  • [1] Host tissue response to floating microelectrode arrays chronically implanted in the feline spinal nerve
    Kolarcik, Christi L.
    Castro, Carlos A.
    Lesniak, Andrew
    Demetris, Anthony J.
    Fisher, Lee E.
    Gaunt, Robert A.
    Weber, Douglas J.
    Cui, X. Tracy
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (04)
  • [2] Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
    Biran, R
    Martin, DC
    Tresco, PA
    EXPERIMENTAL NEUROLOGY, 2005, 195 (01) : 115 - 126
  • [3] Strategies for minimizing glial response to chronically-implanted microelectrode arrays for neural interface
    Lee Y.
    Jun S.B.
    Jun, S. B. (juns@ewha.ac.kr), 1600, Springer Verlag (04): : 120 - 128
  • [4] Wireless microelectrode arrays for selective and chronically stable peripheral nerve stimulation for hindlimb movement
    Frederick, Rebecca A.
    Troyk, Philip R.
    Cogan, Stuart F.
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (05)
  • [5] A technique to prevent dural adhesions to chronically implanted microelectrode arrays
    Maynard, EM
    Fernandez, E
    Normann, RA
    JOURNAL OF NEUROSCIENCE METHODS, 2000, 97 (02) : 93 - 101
  • [6] A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex
    Winslow, Brent D.
    Christensen, Michael B.
    Yang, Wen-Kuo
    Solzbacher, Florian
    Tresco, Patrick A.
    BIOMATERIALS, 2010, 31 (35) : 9163 - 9172
  • [7] Astrocytic Response to Acutely- and Chronically-Implanted Microelectrode Arrays in the Marmoset (Callithrix jacchus) Brain
    Budoff, Samuel A.
    Yano, Kim M.
    de Mesquita, Fernanda C.
    Doerl, Jhulimar G.
    de Santana, Maxwell B.
    Nascimento, Manuela S. L.
    Kunicki, Ana Carolina B.
    de Araujo, Mariana E. P.
    BRAIN SCIENCES, 2019, 9 (02)
  • [8] Characterization of the tissue response to functional multielectrode arrays in the feline spinal nerve
    Kolarcik, Christi L.
    Castro, Carlos A.
    Cui, Xinyan Tracy
    Weber, Douglas J.
    FASEB JOURNAL, 2013, 27
  • [9] The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull
    Biran, Roy
    Martin, Dave C.
    Tresco, Patrick A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) : 169 - 178
  • [10] Biocompatibility of penetrating recording electrode arrays implanted chronically in the feline visual cortex
    McAllister, JP
    Deren-Brabant, K
    Elfar, SD
    Cottaris, NP
    Abrams, GW
    Iezzi, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46