Continuous blood pressure determination during exercise ECG recording

被引:15
|
作者
Barschdorff, D [1 ]
Erig, M [1 ]
机构
[1] Univ Gesamthsch Paderborn, Fachgebiet Elekt Messtech, D-33098 Paderborn, Germany
来源
BIOMEDIZINISCHE TECHNIK | 1998年 / 43卷 / 03期
关键词
blood pressure measurement; exercise ECG; pulse transit time; photoplethysmogram;
D O I
10.1515/bmte.1998.43.3.34
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Using conventional methods (Riva-Rocci, oscillometric), non-invasive blood pressure measurements allow readings to be obtained only at discrete times, at intervals of at least one or two minutes. During exercise ECG recording, continuous blood pressure monitoring capable of detecting brief blood pressure changes is desirable. Our new approach is based on the known dependency of pulse wave velocity and blood pressure. The pulse transit time is derived from an ECG and a simultaneously recorded photoplethysmogram, and the blood pressure is computed using a linear model. In addition to the conventional ECG device, only a finger or ear sensor is required, so that the application of the method is quite easy. Results indicating dynamic blood pressure variations during an exercise ECG are presented.
引用
收藏
页码:34 / 39
页数:6
相关论文
共 50 条
  • [1] METHOD OF ECG RECORDING DURING EXERCISE
    BELOTSERKOVSKY, ZB
    VOROBYEVA, EI
    KARDIOLOGIYA, 1981, 21 (04) : 105 - 107
  • [2] CONTINUOUS ECG RECORDING DURING ESOPHAGOGASTRODUODENOSCOPY
    ALLAZ, AF
    GUILLAUME, P
    MALE, PJ
    DUBAS, J
    ADAMEC, R
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1983, 113 (34) : 1188 - 1191
  • [3] CONTINUOUS BLOOD-PRESSURE RECORDING
    MALLION, JM
    DEBRU, JL
    DEGAUDEMARIS, R
    DIMITRIOU, R
    PERDRIX, A
    CAU, G
    PRESSE MEDICALE, 1985, 14 (03): : 151 - 155
  • [4] Continuous recording of pulse and blood pressure
    Girden, E
    JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1943, 32 (01): : 88 - 90
  • [5] CONTINUOUS RECORDING OF BLOOD-PRESSURE
    MORA, J
    NEFROLOGIA, 1989, 9 (02): : 123 - 125
  • [6] AN AUSCULTATORY RECORDING METHOD FOR BLOOD-PRESSURE MEASUREMENT DURING EXERCISE
    OBARA, S
    YAMAGUCHI, H
    BANDO, E
    MIYAMOTO, H
    JAPANESE JOURNAL OF PHYSIOLOGY, 1987, 37 (04): : 757 - 760
  • [7] VALUE OF AUTOMATIC MONITORING OF ARTERIAL BLOOD-PRESSURE COMBINED WITH CONTINUOUS ECG RECORDING DURING LABOR - PRELIMINARY-RESULTS
    BERKMAN, M
    BERTRAND, P
    DANIEL, C
    GRYNER, S
    NOUVELLE PRESSE MEDICALE, 1981, 10 (29): : 2441 - 2442
  • [8] CONTINUOUS RECORDING OF SYSTOLIC BLOOD PRESSURE DURING THE UNCONSCIOUSNESS OF SUDDEN ANOXIA
    LATHAM, F
    BRITISH HEART JOURNAL, 1947, 9 (04): : 309 - 309
  • [9] Systolic blood pressure estimation using PPG and ECG during physical exercise
    Sun, S.
    Bezemer, R.
    Long, X.
    Muehlsteff, J.
    Aarts, R. M.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (12) : 2154 - 2169
  • [10] BLOOD-PRESSURE FOLLOWER FOR CONTINUOUS BLOOD PRESSURE RECORDING IN MAN
    GREEN, JH