摘要
The aim of this study was to investigate the effects of MR parameters on tissue segmentation and determine the optimal MR sequence for attenuation correction in PET/MR hybrid imaging. Eight healthy volunteers were examined using a PET/MR hybrid scanner with six three-dimensional turbo-field-echo sequences for attenuation correction by modifying the echo time, k-space trajectory in the phase-encoding direction, and image contrast. MR images for attenuation correction were obtained from six MR sequences in each session; each volunteer underwent four sessions. Two radiologists assessed the attenuation correction maps generated from the MR images with respect to segmentation errors and ghost artifacts on a five-point scale, and the scores were decided by consensus. Segmentation accuracy and reproducibility were compared. Multiple regression analysis was performed to determine the effects of each MR parameter. The two three-dimensional turbo-field-echo sequences with an in-phase echo time and radial k-space sampling showed the highest total scores for segmentation accuracy, with a high reproducibility. In multiple regression analysis, the score with the shortest echo time (-3.44, P < 0.0001) and Cartesian sampling in the anterior/posterior phase-encoding direction (-2.72, P = 0.002) was significantly lower than that with in-phase echo time and Cartesian sampling in the right/left phase-encoding direction. Radial k-space sampling provided a significantly higher score (+5.08, P < 0.0001) compared with Cartesian sampling. Furthermore, radial sampling improved intrasubject variations in the segmentation score (-828%, P = 0.002). Image contrast had no significant effect on the total score or reproducibility. These results suggest that three-dimensional turbo-field-echo MR sequences with an in-phase echo time and radial k-space sampling provide improved MR-based attenuation correction maps. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:345 / 352
页数:8
相关论文
共 50 条
  • [1] Towards improved hardware component attenuation correction in PET/MR hybrid imaging
    Paulus, D. H.
    Tellmann, L.
    Quick, H. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 8021 - 8040
  • [2] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 245 - +
  • [3] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [4] MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging
    Izquierdo-Garcia, David
    Catana, Ciprian
    PET CLINICS, 2016, 11 (02) : 129 - +
  • [5] Joint Hardware and Patient Attenuation Correction for Hybrid PET/MR Imaging
    Heusser, T.
    Berker, Y.
    Freitag, M. T.
    Kachelriess, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S340 - S340
  • [6] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)
  • [7] Impact of improved attenuation correction on 18F-FDG PET/MR hybrid imaging of the heart
    Lindemann, Maike E.
    Nensa, Felix
    Quick, Harald H.
    PLOS ONE, 2019, 14 (03):
  • [8] Impact of attenuation correction in hybrid PET/MR imaging of serotonin transporter occupancy
    Rischka, L.
    Hahn, A.
    Gryglewski, G.
    Philippe, C.
    Nics, L.
    Hartenbach, M.
    Traub-Weidinger, T.
    Mitterhauser, M.
    Wadsak, W.
    Hacker, M.
    Kasper, S.
    Lanzenberger, R.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2016, 26 : S303 - S303
  • [9] Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging
    Liu, Fang
    Jang, Hyungseok
    Kijowski, Richard
    Bradshaw, Tyler
    McMillan, Alan B.
    RADIOLOGY, 2018, 286 (02) : 676 - 684
  • [10] Hybrid approach for attenuation correction in PET/MR scanners
    Santos Ribeiro, A.
    Mops, E. Rota
    Herzog, H.
    Almeida, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 166 - 170