Robustness of optimal energy thresholds in photon-counting spectral CT

被引:11
|
作者
Zheng, Yifan [1 ,2 ,3 ]
Yveborg, Moa [4 ]
Gronberg, Fredrik [1 ]
Xu, Cheng [1 ,4 ]
Su, Qianqian [2 ,3 ]
Danielsson, Mats [1 ,4 ]
Persson, Mats [1 ,5 ,6 ]
机构
[1] Albanova Univ Ctr, Royal Inst Technol, Dept Phys, SE-10691 Stockholm, Sweden
[2] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[4] Prismat Sensors AB, Roslagstullsbacken 21, S-10691 Stockholm, Sweden
[5] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[6] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
Photon counting; Spectral CT; Threshold optimization; Silicon-strip detector; CZT detector; SILICON-STRIP DETECTOR; FEASIBILITY; STATISTICS; RESOLUTION;
D O I
10.1016/j.nima.2019.163132
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An important question when developing photon-counting detectors for computed tomography is how to select energy thresholds. In this work thresholds are optimized by maximizing signal-difference-to-noise ratio squared (SDNR2) in an optimally weighted image and signal-to-noise ratio squared (SNR2) in a gadolinium basis image in a silicon-strip detector and a cadmium zinc telluride (CZT) detector, factoring in pileup and imperfect energy response based on real-world detector systems. To investigate to what extent one single set of thresholds could be applied in various imaging tasks, the robustness of optimal thresholds with 2 to 8 bins is examined with the variation of phantom thicknesses, target materials and detector configurations. In contrast to previous studies, the optimal threshold locations do not always increase with increasing attenuation if pileup is included. With respect to the tradeoff between higher SDNR2 or SNR2 and less data, setting optimal thresholds for a 30 cm phantom yields robust SDNR2 and setting optimal thresholds for a 50 cm phantom yields robust SNR2 with 6 to 8 bins in the silicon-strip detector. Furthermore, setting optimal thresholds for a 30 cm phantom yields robust SDNR2 or SNR2 with 6 to 8 bins and a pixel size less than or equal to 0.5 x 0.5 mm(2) in the CZT detector.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Optimization of energy thresholds in photon-counting CT via a virtual clinical trial
    Abadi, Ehsan
    Rajagopal, Jayasai
    Sauer, Thomas
    Jones, Elizabeth
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [2] Spectral photon-counting CT in cardiovascular imaging
    Sandfort, Veit
    Persson, Mats
    Pourmorteza, Amir
    Noel, Peter B.
    Fleischmann, Dominik
    Willemink, Martin J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) : 218 - 225
  • [3] Spectral Imaging: Dual-Energy, MultiEnergy and Photon-Counting CT
    Uhlenbrock, Detlev
    RADIOLOGIE, 2023, 63 (01): : 82 - 83
  • [4] Optimal Selection of Thresholds for Photon Counting CT
    O'Donnell, Thomas
    Schoeck, Friederike
    Cheheltani, Rabee
    Cormode, David
    Fayad, Zahi A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [5] Energy resolution of a segmented silicon strip detector for photon-counting spectral CT
    Xu, Cheng
    Chen, Han
    Persson, Mats
    Karlsson, Staffan
    Danielsson, Mats
    Svensson, Christer
    Bornefalk, Hans
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 715 : 11 - 17
  • [6] A comparison of simulation tools for photon-counting spectral CT
    Nasirudin, Radin A.
    Penchev, Petar
    Mei, Kai
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [7] Spectral Photon-Counting CT Technology in Chest Imaging
    Si-Mohamed, Salim Aymeric
    Miailhes, Jade
    Rodesch, Pierre-Antoine
    Boccalini, Sara
    Lacombe, Hugo
    Leitman, Valerie
    Cottin, Vincent
    Boussel, Loic
    Douek, Philippe
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [8] Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT
    Greffier, Joel
    Villani, Nicolas
    Defez, Didier
    Dabli, Djamel
    Si-Mohamed, Salim
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (04) : 167 - 177
  • [9] Optimal energy threshold arrangement in photon-counting spectral x-ray imaging
    Roessl, Ewald
    Proksa, Roland
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1950 - 1954
  • [10] Adaptive Spectral Inconsistency Modeling for Photon-Counting Detector CT
    Qi, Binxiang
    Gao, Hewei
    MEDICAL PHYSICS, 2020, 47 (06) : E377 - E377