Direct electrochemistry and electrocatalysis of hemoglobin on a glassy carbon electrode modified with poly(ethylene glycol diglycidyl ether) and gold nanoparticles on a quaternized cellulose support. A sensor for hydrogen peroxide and nitric oxide

被引:19
|
作者
Li, Fangping [1 ]
Nie, Mingzhe [1 ]
He, Xiulan [1 ]
Fei, Junjie [1 ]
Ding, Yonglan [1 ]
Feng, Bo [2 ]
机构
[1] Xiangtan Univ, Coll Chem, Minist Educ, Key Lab Environm Friendly Chem & Applicat, Xiangtan 411105, Peoples R China
[2] Xiangtan Univ, Coll Chem Engn, Xiangtan 411105, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
Gold nanoparticles; Poly ethylene glycol diglycidyl ether; Hemoglobin; Direct electrochemistry; Biosensor; IONIC LIQUID; FILM; NANOCOMPOSITE; CATALYSIS;
D O I
10.1007/s00604-014-1228-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode was modified with gold nanoparticles (Au-NPs) on a quaternized cellulose support in a film composed of poly(ethylene glycol diglycidyl ether) (PEGDGE), and Hb was immobilized on the Au-NPs. The sensor film was characterized by UV-vis spectra, scanning electron microscopy, and electrochemical impedance spectroscopy. Cyclic voltammetry of the Hb in the Au@Qc/PEGDGE film revealed a pair of well-defined and quasi reversible peaks for the protein heme Fe(III)/Fe(II) redox couple at about -0.333 V (vs. SCE). The sensor film also exhibited good electrocatalytic activity for the reduction of nitric oxide and hydrogen peroxide. The amperometric response of the biosensor depends linearly on the concentration of nitric oxide in the 0.9 to 160 mu M range, and the detection limit is as low as 12 nM (at 3 sigma). The response to hydrogen peroxide is linear in the 59 nM to 4.6 mu M concentration range, and the detection limit is 16 nM (at 3 sigma). This biosensor is sensitive, reproducible, and long-term stable.
引用
收藏
页码:1541 / 1549
页数:9
相关论文
共 30 条
  • [1] Direct electrochemistry and electrocatalysis of hemoglobin on a glassy carbon electrode modified with poly(ethylene glycol diglycidyl ether) and gold nanoparticles on a quaternized cellulose support. A sensor for hydrogen peroxide and nitric oxide
    Fangping Li
    Mingzhe Nie
    Xiulan He
    Junjie Fei
    Yonglan Ding
    Bo Feng
    Microchimica Acta, 2014, 181 : 1541 - 1549
  • [2] Direct electrochemistry and electrocatalysis of hemoglobin on nanostructured gold colloid-silk fibroin modified glassy carbon electrode
    Guo, Hui-Lin
    Liu, De-Ye
    Yu, Xiao-Dong
    Xia, Xing-Hua
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (02): : 598 - 603
  • [3] Amperometric Biosensor for Hydrogen Peroxide Based on Direct Electrocatalysis by Hemoglobin Immobilized on Gold Nanoparticles/ 1,6-Diaminohexane Modified Glassy Carbon Electrode
    Mingyu Tang
    Shihong Chen
    Ruo Yuan
    Yaqin Chai
    Fengxian Gao
    Yi Xie
    Analytical Sciences, 2008, 24 : 487 - 491
  • [4] Amperometric biosensor for hydrogen peroxide based on direct electrocatalysis by hemoglobin immobilized on gold nanoparticles/1,6-diaminohexane modified glassy carbon electrode
    Tang, Mingyu
    Chen, Shihong
    Yuan, Ruo
    Chai, Yaqin
    Gao, Fengxian
    Xie, Yi
    ANALYTICAL SCIENCES, 2008, 24 (04) : 487 - 491
  • [5] Direct electrochemistry of hemoglobin based on Gemini surfactant protected gold nanoparticles modified glassy carbon electrode
    Li, Jinxia
    Zhou, Lihui
    Han, Xia
    Liu, Honglai
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01): : 322 - 326
  • [6] Direct Electrochemistry and Electrocatalysis of Hemoglobin at PAMAM Dendrimer-MWNTs-Au Nanoparticles Composite Film Modified Glassy Carbon Electrode
    Liu Xing-mei
    Zhang Xue-yu
    Zhao Yi-li
    Liu Wei-lu
    Wang Bao-jun
    Zhang Yi-hua
    Zhang Zhi-quan
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (05) : 723 - 728
  • [8] A reagentless nitric oxide biosensor based on the direct electrochemistry of hemoglobin adsorbed on the gold colloids modified carbon paste electrode
    Xu, Yanxia
    Hu, Chengguo
    Hu, Shengshui
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01): : 253 - 258
  • [9] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Yazhen Wang
    Bin Song
    Junhui Xu
    Shengshui Hu
    Microchimica Acta, 2015, 182 : 711 - 718
  • [10] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718