Asymmetrical loading during sit-to-stand movement in patients 1 year after total hip arthroplasty

被引:9
|
作者
Miura, Namika [1 ]
Tagomori, Keiichi [1 ]
Ikutomo, Hisashi [1 ]
Nakagawa, Norikazu [1 ]
Masuhara, Kensaku [2 ]
机构
[1] Masuhara Clin, Dept Rehabil, Kita Ku, 3-4-2 Tenmabashi, Osaka 5300042, Japan
[2] Masuhara Clin, Dept Orthopaed Surg, Kita Ku, 3-4-2 Tenmabashi, Osaka 5300042, Japan
关键词
Total hip arthroplasty; Sit-to-stand movement; Asymmetrical loading; TOTAL KNEE ARTHROPLASTY; QUALITY-OF-LIFE; OLDER-ADULTS; 1ST YEAR; OSTEOARTHRITIS; REPLACEMENT; RECOVERY; OUTCOMES; CHAIR; TASK;
D O I
10.1016/j.clinbiomech.2018.06.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Asymmetrical loading during functional performance can occur after total hip arthroplasty. We hypothesized that during sit-to-stand movements, the loading of the limbs of patients who undergo total hip arthroplasty is more asymmetrical than that of those who do not. The objective of the present study was to compare asymmetrical loading during the sit-to-stand movements of patients at 1 year after undergoing total hip arthroplasty, and that of healthy adults. Methods: Twenty-eight patients at 1 year after undergoing total hip arthroplasty and 16 healthy adults were included. We measured the vertical ground reaction force during the sit-to-stand movement for each leg and calculated the ratio of the peak vertical ground reaction force, and the ratio at the time of peak magnitude of the non-operated limb (control, right limb). Findings: The mean peak vertical ground reaction force ratio of the patients was 0.77 (0.2), and it was significantly lower than that of healthy adults. The vertical ground reaction force ratio for these patients at the time of peak magnitude of the non-operated limb was 0.72 (0.2), and was significantly lower than that of healthy adults. Interpretation: Loading on the operated leg during the sit-to-stand movement was lower than that on the non operated leg in patients at 1 year after undergoing total hip arthroplasty. Furthermore, loading during sit-to stand movement of patients 1 year after undergoing total hip arthroplasty was more asymmetrical than that of healthy adults. Even at 1 year after undergoing total hip arthroplasty, these patients performed the sit-to-stand movement asymmetrically.
引用
收藏
页码:89 / 92
页数:4
相关论文
共 50 条
  • [1] Leg loading during quiet standing and sit-to-stand movement for one year after total hip arthroplasty
    Miura, Namika
    Tagomori, Keiichi
    Ikutomo, Hisashi
    Nakagawa, Norikazu
    Masuhara, Kensaku
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (07) : 529 - 533
  • [2] Sit-To-Stand Biomechanics Before and After Total Hip Arthroplasty
    Abujaber, Sumayeh B.
    Marmon, Adam R.
    Pozzi, Federico
    Rubano, James J.
    Zeni, Joseph A., Jr.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (11): : 2027 - 2033
  • [3] Functional movement compensations persist in individuals with hip osteoarthritis performing the five times sit-to-stand test 1 year after total hip arthroplasty
    Anna-Clara Esbjörnsson
    Josefine E. Naili
    Journal of Orthopaedic Surgery and Research, 15
  • [4] Functional movement compensations persist in individuals with hip osteoarthritis performing the five times sit-to-stand test 1 year after total hip arthroplasty
    Esbjornsson, Anna-Clara
    Naili, Josefine E.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [5] Preoperative Ambulatory Measurement of Asymmetric Leg Loading During Sit-to-Stand in Hip Arthroplasty Patients
    Martinez-Ramirez, Alicia
    Weenk, Dirk
    Lecumberri, Pablo
    Verdonschot, Nico
    Pakvis, Dean
    Veltink, Peter H.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2014, 22 (03) : 585 - 592
  • [6] The Sit-to-Stand Movement: Differences in Performance Between Patients After Primary Total Hip Arthroplasty and Revision Total Hip Arthroplasty With Acetabular Bone Impaction Grafting
    Boonstra, Miranda C.
    Schreurs, B. Wim
    Verdonschot, Nico
    PHYSICAL THERAPY, 2011, 91 (04): : 547 - 554
  • [7] Persistence of altered movement patterns during a sit-to-stand task 1 year following unilateral total knee arthroplasty
    Farquhar, Sara J.
    Reisman, Darcy S.
    Snyder-Mackler, Lynn
    PHYSICAL THERAPY, 2008, 88 (05): : 567 - 579
  • [8] Kinematic and Kinetic Changes after Total Hip Arthroplasty during Sit-To-Stand Transfers: Systematic Review
    Wang, Junsig
    Siddicky, Safeer F.
    Dohm, Michael P.
    Barnes, C. Lowry
    Mannen, Erin M.
    ARTHROPLASTY TODAY, 2021, 7 : 148 - 156
  • [9] Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty
    Mizner, RL
    Snyder-Mackler, L
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (05) : 1083 - 1090
  • [10] Asymmetrical hip loading correlates with metal ion levels in patients with metal-on-metal hip resurfacing during sit-to-stand
    Mellon, Stephen
    Grammatopoulos, George
    Pandit, Hemant
    Murray, David W.
    Gill, Harinderjit S.
    HIP INTERNATIONAL, 2014, 24 (01) : 20 - 26