Heterochromatic Flicker Photometry for Objective Lens Density Quantification

被引:23
|
作者
Najjar, Raymond P. [1 ,2 ,3 ,4 ]
Teikari, Petteri [1 ,2 ]
Cornut, Pierre-Loic [1 ,5 ]
Knoblauch, Kenneth [1 ,2 ]
Cooper, Howard M. [1 ,2 ]
Gronfier, Claude [1 ,2 ]
机构
[1] INSERM, U1208, Stem Cell & Brain Res Inst, F-69500 Bron, France
[2] Univ Lyon 1, F-69365 Lyon, France
[3] Stanford Univ, Dept Psychiat & Behav Sci, Stanford, CA 94305 USA
[4] Vet Affairs Palo Alto Hlth Care Syst, Mental Illness Res Educ & Clin Ctr, Palo Alto, CA USA
[5] Hop Edouard Herriot, CHU Lyon, Dept Ophthalmol, Lyon, France
关键词
heterochromatic flicker photometry; light; lens density; ocular media; psychophysics; clinical; photoreception; cataract; non-image forming; circadian; MELATONIN SUPPRESSION; CATARACT-SURGERY; OPTICAL-DENSITY; ACTION SPECTRUM; LIGHT; SYSTEM; AGE; TRANSMITTANCE; OPACITIES; NUCLEAR;
D O I
10.1167/iovs.15-18642
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Although several methods have been proposed to evaluate lens transmittance, to date there is no consensual in vivo approach in clinical practice. The aim of this study was to compare ocular lens density and transmittance measurements obtained by an improved psychophysical scotopic heterochromatic flicker photometry (sHFP) technique to the results obtained by three other measures: a psychophysical threshold technique, a Scheimpflug imaging technique, and a clinical assessment using a validated subjective scale. METHODS. Forty-three subjects (18 young, 9 middle aged, and 16 older) were included in the study. Individual lens densities were measured and transmittance curves were derived from sHFP indexes. Ocular lens densities were compared across methods by using linear regression analysis. RESULTS. The four approaches showed a quadratic increase in lens opacification with age. The sHFP technique revealed that transmittance decreased with age over the entire visual spectrum. This decrease was particularly pronounced between young and older participants in the short (53.03% decrease in the 400-500 nm range) wavelength regions of the light spectrum. Lens density derived from sHFP highly correlated with the values obtained with the other approaches. Compared to other objective measures, sHFP also showed the lowest variability and the best fit with a quadratic trend (r(2) = 0.71) of lens density increase as a function of age. CONCLUSIONS. The sHFP technique offers a practical, reliable, and accurate method to measure lens density in vivo and predict lens transmittance over the visible spectrum. An accurate quantification of lens transmittance should be obtained in clinical practice, but also in research in visual and nonvisual photoreception.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 50 条
  • [1] Heterochromatic flicker photometry
    Bone, RA
    Landrum, JT
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2004, 430 (02) : 137 - 142
  • [2] HETEROCHROMATIC FLICKER PHOTOMETRY IN GOLDFISH
    BILOTTA, J
    DEMARCO, PJ
    LAJOIE, AS
    DIECKMANN, CM
    CHATMAN, SJ
    COSBY, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2168 - 2168
  • [3] Improving the repeatability of heterochromatic flicker photometry for measurement of macular pigment optical density
    Olivia Howells
    Frank Eperjesi
    Hannah Bartlett
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 871 - 880
  • [4] Macular pigment density determination: Heterochromatic flicker photometry and scanning laser reflectometry
    Ponce, EA
    Nieto, J
    Rosen, R
    Garcia, J
    Garcia, P
    Gentile, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U603 - U603
  • [5] Improving the repeatability of heterochromatic flicker photometry for measurement of macular pigment optical density
    Howells, Olivia
    Eperjesi, Frank
    Bartlett, Hannah
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (03) : 871 - 880
  • [6] The validity of flicker photometer measurements in heterochromatic photometry
    Taylor, A
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA AND REVIEW OF SCIENTIFIC INSTRUMENTS, 1926, 13 (02): : 193 - 203
  • [7] REFINING THE MEASUREMENT OF MPOD BY HETEROCHROMATIC FLICKER PHOTOMETRY
    Richard, Bone A.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (04) : 604 - 604
  • [8] Macular pigment density measured by autofluorescence spectrometry: Comparison with reflectometry and heterochromatic flicker photometry
    Delori, François C.
    Goger, Douglas G.
    Hammond, Billy R.
    Snodderly, D. Max
    Burns, Stephen A.
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 2001, 18 (06): : 1212 - 1230
  • [9] Macular pigment optical density measurements: evaluation of a device using heterochromatic flicker photometry
    de Kinkelder, R.
    van der Veen, R. L. P.
    Verbaak, F. D.
    Faber, D. J.
    van Leeuwen, T. G.
    Berendschot, T. T. J. M.
    EYE, 2011, 25 (01) : 105 - 112
  • [10] Macular pigment optical density measurements: evaluation of a device using heterochromatic flicker photometry
    R de Kinkelder
    R L P van der Veen
    F D Verbaak
    D J Faber
    T G van Leeuwen
    T T J M Berendschot
    Eye, 2011, 25 : 105 - 112