Comparative study of two different techniques of diode laser transscleral cyclophotocoagulation in management of refractory glaucoma

被引:0
|
作者
Gabr, Ahmed F. [1 ]
El Razeq, Muhammad M. A. [2 ]
Abdalla, Abdalla M. A. [1 ]
机构
[1] Aswan Univ, Fac Med, Dept Ophthalmol, Aswan, Egypt
[2] Aswan Univ, Dept Ophthalmol, Aswan, Egypt
关键词
cyclophotocoagulation; diode laser; intraocular pressure; refractory glaucoma;
D O I
10.4103/ejos.ejos_66_19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The aim was to compare between two techniques of diode laser transscleral cyclophotocoagulation in treatment of refractory glaucoma, that is, standard titratable (audible pops' technique) versus slow coagulation technique, regarding and efficacy. Patients and methods In this prospective randomized study, 40 patients with refractory glaucoma were divided into two study groups: group A underwent standard technique of diode laser transscleral cyclophotocoagulation (audible pops technique), and group B underwent slow coagulation technique of diode laser transscleral cyclophotocoagulation. Patients were followed up at 1 week, 1 month, 3 month, and 6 month duration postoperatively, and changes in visual acuity, intraocular pressure (IOP), as well as postoperative complications were documented. Results The mean IOP was reduced significantly from 46.3 +/- 8.9 to 18.9 +/- 5.45 mmHg in patient of group A and from 42.8 +/- 8.53 to 20.05 +/- 8.28 mmHg in patient of group B at the end of 6-month follow-up (P<0.0001). The mean number of postoperative antiglaucoma drugs needed to control IOP was also reduced significantly in both groups. No serious complications such as hypotony were reported in the two study groups. Conclusion Both techniques of diode transscleral cyclophotocoagulation were of near equal safety and efficacy in treatment of refractory glaucoma with different underlying etiologies. Both had good efficacy in IOP lowering, reduced number of antiglaucoma medications used by patients, and relieved pain, with near equal incidence of postoperative complications.
引用
收藏
页码:154 / 159
页数:6
相关论文
共 50 条
  • [1] Transscleral Diode Laser Cyclophotocoagulation in Refractory Glaucoma
    Bitirgen, Gulfidan
    Okka, Mehmet
    Bozkurt, Banu
    Dogru, Ismail
    Kerimoglu, Hurkan
    Ozturk, Banu Turgut
    Kamis, Umit
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2012, 42 (06): : 434 - 437
  • [2] Diode laser transscleral cyclophotocoagulation for refractory glaucoma
    Mistlberger, A
    Liebmann, JM
    Tschiderer, H
    Ritch, R
    Ruckhofer, J
    Grabner, G
    [J]. JOURNAL OF GLAUCOMA, 2001, 10 (04) : 288 - 293
  • [3] EFFICACY OF CYCLOCRYOTHERAPY AND TRANSSCLERAL DIODE LASER CYCLOPHOTOCOAGULATION IN THE MANAGEMENT OF REFRACTORY GLAUCOMA
    Miljkovic, Aleksandar
    Babic, Nikola
    Canadanovic, Vladimir A.
    Davidovic, Sofija
    Ljikar, Jelena
    Vasin, Marija
    [J]. ACTA CLINICA CROATICA, 2021, 60 (02) : 171 - 177
  • [4] Comparison of two protocols of diode laser transscleral cyclophotocoagulation in refractory glaucoma
    Koronis, Spyridon
    Matsou, Artemis
    Tzamalis, Argyrios
    Dermenoudi, Maria
    Ziakas, Nikolaos
    Anastasopoulos, Eleftherios
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 976 - 983
  • [5] Transscleral diode laser cyclophotocoagulation in refractory glaucoma in Korea
    Youn, J
    Moon, I
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S271 - S271
  • [6] Contact transscleral diode laser cyclophotocoagulation for refractory glaucoma
    Suresh, PS
    Sandramouli, S
    Corridan, PGJ
    [J]. SOE '97 - XI CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, VOLS 1 AND 2, 1997, : 539 - 542
  • [7] Transscleral contact diode laser cyclophotocoagulation in refractory glaucoma
    Hamard, P
    Gayraud, JM
    Kopel, J
    Valtot, F
    Hamard, H
    Haut, J
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1203 - 1203
  • [8] Micropulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma
    Tan, Anna M.
    Chockalingam, Muthuraman
    Aquino, Maria C.
    Lim, Zena I-L
    See, Jovina L-S
    Chew, Paul T. K.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (03): : 266 - 272
  • [9] DIODE-LASER TRANSSCLERAL CYCLOPHOTOCOAGULATION IN EARLY REFRACTORY GLAUCOMA
    LEONI, G
    LUPPI, ML
    PENNE, A
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S559 - S559
  • [10] Contact transscleral diode cyclophotocoagulation for refractory glaucoma
    Threlkeld, AB
    Johnson, MH
    [J]. JOURNAL OF GLAUCOMA, 1999, 8 (01) : 3 - 7