Determination of Rotenone Residues in Foodstuffs by Solid-Phase Extraction (SPE) and Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

被引:7
|
作者
Xu Dun-ming [1 ]
Zhou Yu [1 ]
Lin Li-yi [1 ]
Zhang Zhi-gang [1 ]
Zhang Jin [1 ]
Lu Sheng-yu [2 ]
Yang Fang [2 ]
Huang Peng-ying [1 ]
机构
[1] Xiamen Entry Exit Inspect & Quarantine Bur, Xiamen 361026, Peoples R China
[2] Fujian Entry Exit Inspect & Quarantine Bur, Fuzhou 350001, Peoples R China
来源
AGRICULTURAL SCIENCES IN CHINA | 2010年 / 9卷 / 09期
关键词
rotenone; LC-MS/MS; foodstuff; residue; SPE;
D O I
10.1016/S1671-2927(09)60220-0
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
We developed a novel approach to determine rotenone residues in foodstuffs, by integrating solid-phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC-MS/MS) technologies, to achieve high sensitivity and selectivity. In our method, the solvent extraction with n-hexane-dichloromethane (50:50, v/v) and cleanup with florisil SPE cartridges using ethyl acetate-ethyl ether (25:75, v/v) as eluents provided adequate recovery of rotenone. The detection of rotenone was then carried out by LC-MS/MS using acetonitrile-water with the 0.1% formic acid (w/v) as the mobile phase. The multiple reaction monitoring (MRM) scheme employed in the approach involved the transitions of the precursor ion to three selected product ions, in which one pair for quantification was m/z 395.3 > 213.2 and the other two pairs for identification were m/z 395.3 > 192.2 and 395.3 > 367.0. The limits of quantification (LOQs) of the method ranged from 0.001 to 0.005 mg kg(-1) depending on the matrix. Intra- and inter-day precisions (relative standard deviations, RSDs) for rotenone were less than 7.1 and 14.8%, respectively. Results from repetitive analysis suggested good reproducibility of the method for rotenone residue detection. The recoveries at three concentrations (LOQ, 10LOQ and 100LOQ) ranged from 79.3-118.3% in cabbage, potato, onion, carrot, apple, orange, banana, lichee, tea, and Shiitake mushroom. The proposed procedure was then applied to the analysis of 129 real samples collected from Xiamen, Fujian Province, China. The existence of rotenone was found in two tea products with concentrations of 0.012 and 0.016 mg kg(-1), respectively. The method has great potential for routine analysis of monitoring rotenone residue in foodstuffs.
引用
收藏
页码:1299 / 1308
页数:10
相关论文
共 50 条
  • [2] Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Alam, Md Tauquir
    Mujtaba, Md Ali
    Hussain, Afzal
    Ali, Abuzer
    Imran, Mohd
    Abul Barkat, Md
    Abdel-Gawad, Sherif A.
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 61 (04) : 366 - 374
  • [3] Determination of Sedative and Anesthetic Drug Residues in Aquatic Food Products Using Solid Phase Extraction (SPE) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Xin, Lina
    Chen, Yun
    Li, Minglu
    Liang, Feiyan
    Xia, Ning
    Wang, Li
    [J]. ANALYTICAL LETTERS, 2024,
  • [4] Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples
    Koo, So Hyun
    Jo, Cheon Ho
    Shin, Sun Kyoung
    Myung, Seung-Woon
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (05): : 1192 - 1198
  • [5] Method for the determination of perfluorinated compounds (PFCs) in water by solid-phase extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS)
    Wolf, Susan T.
    Reagen, William K.
    [J]. ANALYTICAL METHODS, 2011, 3 (07) : 1485 - 1493
  • [6] Determination of Pharmaceutical Residues in Fish Bile by Solid-Phase Microextraction Couple with Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS)
    Togunde, Oluranti P.
    Oakes, Ken D.
    Servos, Mark R.
    Pawliszyn, Janusz
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (10) : 5302 - 5309
  • [7] Determination of ampicillin in human plasma by solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) and its use in bioequivalence studies
    Goncalves, Talita Mota
    Galindo Bedor, Danilo Cesar
    Pires de Abreu, Luis Renato
    Miranda de Sousa, Carlos Eduardo
    Bueno Rolim, Clarice M.
    de Santana, Davi Pereira
    [J]. ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2008, 58 (02): : 91 - 96
  • [8] Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) (vol 61, pg 366, 2023)
    Alam, Md Tauquir
    Barkat, Md Abul
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023,
  • [9] Analysis of ketamine and norketamine in hair samples using molecularly imprinted solid-phase extraction (MISPE) and liquid chromatography–tandem mass spectrometry (LC-MS/MS)
    Norlida Harun
    Robert A. Anderson
    Peter A. G. Cormack
    [J]. Analytical and Bioanalytical Chemistry, 2010, 396 : 2449 - 2459
  • [10] Determination of 19 sulfonamides in environmental water samples by automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS)
    Jesus Garcia-Galan, M.
    Silvia Diaz-Cruz, M.
    Barcelo, Damia
    [J]. TALANTA, 2010, 81 (1-2) : 355 - 366