Evaluation of CFD accuracy for the ventilation study of a naturally ventilated broiler house

被引:59
|
作者
Lee, In-Bok
Sase, Sadanori [1 ]
Sung, Si-Heung
机构
[1] Natl Inst Rural Engn, Dept Rural Technol, Tsukuba, Ibaraki 3058609, Japan
[2] Seoul Natl Univ, Dept Rural Syst Engn, Seoul 151742, South Korea
[3] Konkuk Univ, Dept Biosyst Engn, Chungju 380701, South Korea
来源
关键词
aerodynamics; computational fluid dynamics; natural ventilation; particle image velocimetry; wind tunnel;
D O I
10.6090/jarq.41.53
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Using the CFD model, a new ventilation system design will be found later taking into consideration the ventilation efficiency such as uniformity, stability, and suitability of environmental factors in a naturally ventilated broiler house. Because conducting a field experiment for the ventilation study presented so many difficulties, a reliable 3-dimentional computational fluid dynamics (CFD) model had to be developed to investigate the natural ventilation. Before investigating its accuracy, a wind tunnel and particle image velocimetry (PIV) test was initially conducted to find their best experimental conditions and improve the PIV accuracy(13,15). A 1/20 scale model of a naturally ventilated broiler house was used to get qualitative and quantitative airflow distribution in the broiler house using the PIV and CFD. To improve the CFD accuracy, the PIV and CFD computed airflows in the broiler house were compared, particularly on the distribution, local air velocity, and turbulent intensity in the house. The quality of the mesh density and the design of the boundary condition, especially the wind velocity and turbulence profiles, were found to be very important for getting accurate results. Assuming the PIV results were accurate, the most accurate CFD results were obtained when using a RNG k-epsilon turbulence numerical model. The average error of the CFD computed air velocity when using the RNG k-epsilon models was -6.2%.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 50 条
  • [1] Improvement of the ventilation system of a naturally ventilated broiler house in the cold season using computational simulations
    Seo, I. -H.
    Lee, I. -B.
    Moon, O. -K.
    Kim, H. -T.
    Hwang, H. -S.
    Hong, S. -W.
    Bitog, J. P.
    Yoo, J. -I.
    Kwon, K. -S.
    Kim, Y. -H.
    Han, J. -W.
    [J]. BIOSYSTEMS ENGINEERING, 2009, 104 (01) : 106 - 117
  • [2] Ammonia emissions from a naturally and a mechanically ventilated broiler house in Brazil
    Mendes, Luciano B.
    Tinoco, Ilda F. F.
    Ogink, Nico W. M.
    Rocha, Keller S. O.
    Osorio, Jairo A. S.
    Santos, Marilu S.
    [J]. REVISTA BRASILEIRA DE ENGENHARIA AGRICOLA E AMBIENTAL, 2014, 18 (11): : 1179 - 1185
  • [3] Measurement of culturable airborne staphylococci downwind from a naturally ventilated broiler house
    Schulz, J.
    Formosa, L.
    Seedorf, J.
    Hartung, J.
    [J]. AEROBIOLOGIA, 2011, 27 (04) : 311 - 318
  • [4] Measurement of culturable airborne staphylococci downwind from a naturally ventilated broiler house
    J. Schulz
    L. Formosa
    J. Seedorf
    J. Hartung
    [J]. Aerobiologia, 2011, 27 : 311 - 318
  • [5] Shading screens and ventilation efficiency in a naturally ventilated greenhouse by means of CFD modeling
    Santolini, E.
    Barbaresi, A.
    Pulvirenti, B.
    Torreggiani, D.
    Tassinari, P.
    [J]. VI INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF MODELLING AS AN INNOVATIVE TECHNOLOGY IN THE HORTICULTURAL SUPPLY CHAIN MODEL-IT 2019, 2021, 1311 : 327 - 334
  • [6] A CFD study of the thermal environment in naturally ventilated classrooms
    Li, Qiong
    Meng, Qinglin
    Gong, Bo
    [J]. 2006 XI'AN INTERNATIONAL CONFERENCE OF ARCHITECTURE AND TECHNOLOGY, PROCEEDINGS: ARCHITECTURE IN HARMONY, 2006, : 707 - +
  • [7] CFD Analysis of Broiler House Ventilation Patterns with Respect to the Poultry Welfare
    Zajicek, Milan
    Kic, Pavel
    [J]. RURAL DEVELOPMENT 2013: PROCEEDINGS VOL 6, BOOK 3, 2013, 6 (03): : 151 - 156
  • [8] Energy consumption and ventilation performance of a naturally ventilated ecological house in a cold climate
    Simonson, C
    [J]. ENERGY AND BUILDINGS, 2005, 37 (01) : 23 - 35
  • [9] A CFD evaluation of naturally ventilated, multi-span, sawtooth greenhouses
    Kacira, M
    Short, TH
    Stowell, RR
    [J]. TRANSACTIONS OF THE ASAE, 1998, 41 (03): : 833 - 836
  • [10] MODEL STUDY OF ALTERNATIVE VENTILATION SYSTEMS FOR A BROILER HOUSE
    WILSON, JD
    BISHOP, RG