Data-Driven Dose-Volume Histogram Prediction

被引:3
|
作者
Polizzi, Mitchell [1 ,2 ]
Watkins, Robert W. [1 ]
Watkins, William T. [1 ,3 ,4 ]
机构
[1] Univ Virginia, Radiat Oncol, Charlottesville, VA USA
[2] Virginia Commonwealth Univ, Radiat Oncol, Richmond, VA USA
[3] State Univ, Virginia Polytech Inst, Blacksburg, VA USA
[4] City Hope Natl Med Ctr, Duarte, CA USA
关键词
MODULATED RADIATION-THERAPY; TREATMENT PLAN QUALITY; ORGANS-AT-RISK; IMRT; RADIOTHERAPY; CENTERS; DVH;
D O I
10.1016/j.adro.2021.100841
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate dose-volume histogram (DVH) prediction from prior radiation therapy data. Methods and Materials: An Oncospace radiation therapy database was constructed including images, structures, and dose distributions for patients with advanced lung cancer. DVH data was queried for total lungs, esophagus, heart, and external body contours. Each query returned DVH data for the N-most similar organs at risk (OARs) based on OAR-to-planning-target-volume (PTV) geometry via the overlap volume histogram (OVH). The DVHs for 5, 20, and 50 of the most similar OVHs were returned for each OAR for each patient. The OVH(0cm) is the relative volume of the OAR overlapping with the PTV, and the OVH(2cm) is the relative volume of the OAR 2 cm away from the PTV. The OVH(cm) and DVH(%) queried from the database were separated into interquartile ranges (IQRs), nonoutlier ranges (NORs) (equal to 3 pound IQR), and the average database DVH (DVH-DB) computed from the NOR data. The ability to predict the clinically delivered DVH was evaluated based on percentiles and differences between the DVH-DB and the clinical DVH (DVH-CL) for a varying number of returned patient DVHs for a subset of patients. Results: The ability to predict the clinically delivered DVH was excellent in the lungs and body; the IQR and NOR were <4% and <16%, respectively, in the lungs and <1% and <5%, respectively, in the body at all distances less than 2 cm from the PTV. For 21/23 patients considered, the differences in lung DVH-DB and DVH-CL were <4.6% and in 14/23 cases, <3%. In esophagus and heart, the ability to predict DVH-CL was weaker, with mean DVH differences >10% for 12/23 esophagi and 10/23 hearts. In esophagus and heart queries, the NOR was often 10% to 100% volume in dose ranges between 0% and 50% of prescription, independent of the number of patients queried. Conclusions: Using prior data to predict clinical dosimetry is increasingly of interest, but model- and data-driven methods have limitations if based on limited data sets. This study's results showed that prediction may be reasonable in organs containing tumors with known overlap, but for nonoverlapped OARs, planning preference and plan design may dominate the clinical dose. (c) 2021 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Data-Driven Dose Volume Histogram Prediction
    Polizzi, M.
    Watkins, R.
    Watkins, W.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E734 - E735
  • [2] DATA-DRIVEN APPROACH TO GENERATING ACHIEVABLE DOSE-VOLUME HISTOGRAM OBJECTIVES IN INTENSITY-MODULATED RADIOTHERAPY PLANNING
    Wu, Binbin
    Ricchetti, Francesco
    Sanguineti, Giuseppe
    Kazhdan, Michael
    Simari, Patricio
    Jacques, Robert
    Taylor, Russell
    McNutt, Todd
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (04): : 1241 - 1247
  • [3] Dose-volume histogram prediction using density estimation
    Munter, Johanna Skarpman
    Sjolund, Jens
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17): : 6923 - 6936
  • [4] QA of Dose-Volume Histogram
    Cheng, C.
    Das, I.
    Srivastava, S.
    Gao, Z.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Treatment plan evaluation using dose-volume histogram (DVH) and spatial dose-volume histogram (zDVH)
    Cheng, CW
    Das, IJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05): : 1143 - 1150
  • [6] Pitfalls in Dose-Volume Histogram Computations
    Kaster, F.
    Aznar, M.
    Kadir, T.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Reconsidering the definition of a dose-volume histogram
    Nioutsikou, E
    Webb, S
    Panakis, N
    Bortfeld, T
    Oelfke, U
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (11): : L17 - L19
  • [8] Evaluation of two dose-volume histogram reduction models for the prediction of radiation pneumonitis
    Kwa, SLS
    Theuws, CM
    Wagenaar, A
    Damen, EMF
    Boersma, LJ
    Baas, P
    Muller, SH
    Lebesque, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) : 61 - 69
  • [9] Gastrointestinal Toxicity Prediction Not Influenced by Rectal Contour or Dose-Volume Histogram Definition
    Brand, Douglas H.
    Bruningk, Sarah C.
    Wilkins, Anna
    Naismith, Olivia
    Gao, Annie
    Syndikus, Isabel
    Dearnaley, David P.
    Hall, Emma
    van As, Nicholas
    Tree, Alison C.
    Gulliford, Sarah
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (05): : 1163 - 1173
  • [10] A theoretical approach to the problem of dose-volume constraint estimation and their impact on the dose-volume histogram selection
    Schinkel, Colleen
    Stavrev, Pavel
    Stavreva, Nadia
    Fallone, B. Gino
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3444 - 3459