Improvement of signal-to-noise ratio of electropherograms and analysis reproducibility with digital signal processing and multiple injections

被引:0
|
作者
Kuldvee, R
Kaljurand, M
Smit, HC
机构
[1] Inst Chem, EE-0026 Tallinn, Estonia
[2] Univ Amsterdam, Analyt Chem Lab, NL-1018 WV Amsterdam, Netherlands
来源
关键词
CZE; detection limit; signal-to-noise ratio; correlation chromatography; reproducibility;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poor signal-to-noise ratios and analytical reproducibility in capillary electrophoresis were improved by application of multiple injections of the same sample at (pseudo) randomly chosen time moments. One order of signal-to-noise ratio improvement was achieved in practice using an in-house developed computer-controlled pneumatic sampler. However, it is demonstrated here that better implementation of the capabilities of multiple input requires that the detector signal noise be "pre-whitened", i.e. spikes, baseline drift, oscillations etc, must be removed from the detector signal before transforming it to the electropherogram in the common form. Such filtering of the detector signal was realized by implementing iterative, menu-driven software written in Matlab, a high-level programming language.
引用
下载
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [1] Improvement of the signal-to-noise ratio in digital holography
    Garcia-Sucerquia, J
    Ramírez, JH
    Prieto, DV
    REVISTA MEXICANA DE FISICA, 2005, 51 (01) : 76 - 81
  • [2] Signal-to-noise ratio improvement in multiple electrode recording
    Musial, PG
    Baker, SN
    Gerstein, GL
    King, EA
    Keating, JG
    JOURNAL OF NEUROSCIENCE METHODS, 2002, 115 (01) : 29 - 43
  • [3] Signal-to-noise ratio of digital photographs
    Shaw, R
    IS&T'S NIP14: INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, PROCEEDINGS, 1998, : 582 - 585
  • [4] Signal-to-noise ratio in stretch processing
    Long, T.
    Wang, Y.
    Zeng, T.
    ELECTRONICS LETTERS, 2010, 46 (10) : 720 - 721
  • [5] Digital signal processing for optical particle counters in order to improve the signal-to-noise ratio
    Trampe, A
    Nierhoff, T
    Semleit, D
    Fissan, H
    AEROSOL SCIENCE AND TECHNOLOGY, 1996, 25 (04) : 399 - 410
  • [6] Improvement of signal-to-noise ratio in super resolution imaging using subdiffraction limited spots by additional digital signal processing
    Yamada, Riki
    Ogura, Yusuke
    Nishimura, Takahiro
    Tamada, Yosuke
    Murata, Takashi
    Tanida, Jun
    BIOMEDICAL IMAGING AND SENSING CONFERENCE 2020, 2020, 11521
  • [7] Signal-to-noise ratio, signal processing, and spectral information in the instrumental analysis laboratory
    Blitz, JP
    Klarup, DG
    JOURNAL OF CHEMICAL EDUCATION, 2002, 79 (11) : 1358 - 1360
  • [8] Improvement of signal-to-noise ratio in digital holography using wavelet transform
    Sharma, Akshay
    Sheoran, Gyanendra
    Jaffery, Z. A.
    OPTICS AND LASERS IN ENGINEERING, 2008, 46 (01) : 42 - 47
  • [9] IMPROVEMENT OF SIGNAL-TO-NOISE RATIO IN RESISTIVITY PROFILES
    BERNABINI, M
    BRIZZOLARI, E
    PIRO, S
    GEOPHYSICAL PROSPECTING, 1988, 36 (05) : 559 - 570
  • [10] Signal-to-noise ratio improvement of EMCCD cameras
    Zhang, Wen W.
    Chen, Qian
    Zhou, Bei B.
    He, Wei J.
    World Academy of Science, Engineering and Technology, 2010, 65 : 1152 - 1156