Performance of an in-situ alpha spectrometer

被引:3
|
作者
Pollanen, R. [1 ]
机构
[1] STUK Radiat & Nucl Safety Author, POB 14, FI-00881 Helsinki, Finland
关键词
In-situ alpha spectrometry; Silicon detector; Detection efficiency; RESOLUTION;
D O I
10.1016/j.apradiso.2015.11.110
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Equipment was recently developed for detecting alpha particles from flat and smooth surfaces with good energy resolution at ambient air pressure. In this work, the detection efficiencies were determined using different extended-area sources emitting alpha and beta radiation and a mixed nuclide point source emitting alpha radiation. Beta particles are of importance because they can also be detected. Counts originating from alpha and beta particles are mainly at different energies, which make their separation possible. An efficiency of 0.14 was determined for an extended-area (> 30 cm(2)) homogeneous source emitting alpha radiation at the energy of 5-6 MeV, whereas for the beta emitters the efficiencies were 0.07-0.19 depending on the beta-particle emission energies. The use of a collimator reduces the detection efficiencies by a factor of up to ten. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 50 条
  • [1] In-situ determination of the performance of the ATLAS muon spectrometer
    Antonelli, M.
    Bagnaia, P.
    Boyko, I.
    Benekos, N.
    Bruni, A.
    Chevalier, L.
    Gatti, C.
    Gostkin, M.
    Guyot, C.
    Giovanella, S.
    Eppig, A.
    Van Eldik, N.
    Kluit, P.
    Kortner, O.
    Laporte, J. -F.
    Maccarrone, G.
    Miscetti, S.
    Nikolaev, K.
    Orestano, D.
    Petrucci, F.
    Rebuzzi, D.
    Schmaler, J.
    Spogli, L.
    Schott, M.
    Wilson, A.
    Zhou, B.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2008, 177 : 326 - 327
  • [2] In-situ mass-spectrometer of magnetized plasmas
    Sorokin, I. A.
    Vizgalov, I. V.
    Kurnaev, V. A.
    Brandt, C.
    Kreter, A.
    Linsmeier, Ch
    NUCLEAR MATERIALS AND ENERGY, 2017, 12 : 1243 - 1247
  • [3] HPGE SPECTROMETER AS A GAMMA-RAY DOSIMETER IN-SITU
    KRNAC, S
    RAGAN, P
    RADIATION PROTECTION DOSIMETRY, 1995, 58 (03) : 217 - 228
  • [4] An in-situ gamma-ray spectrometer for the deep ocean
    Tsabaris, C.
    Androulakaki, E. G.
    Alexakis, S.
    Patiris, D. L.
    APPLIED RADIATION AND ISOTOPES, 2018, 142 : 120 - 127
  • [5] In-situ phase analysis by a versatile miniaturized Mossbauer spectrometer
    Klingelhofer, G
    Held, P
    Bernhardt, B
    Foh, J
    Teucher, R
    Kankeleit, E
    HYPERFINE INTERACTIONS, 1998, 111 (1-4): : 331 - 334
  • [6] PERFORMANCE STANDARDS FOR IN-SITU BIOREMEDIATION
    MACDONALD, JA
    RITTMANN, BE
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (10) : 1974 - 1979
  • [7] In-situ measurement of window performance
    Carpenter, Stephen
    ASHRAE Journal, 1991, 33 (01) : 14 - 16
  • [8] Gauging the performance of an in-situ interferometer
    Terry, M
    Smith, A
    Rebitz, K
    OPTICAL MICROLITHOGRAPHY XIII, PTS 1 AND 2, 2000, 4000 : 1223 - 1236
  • [9] In-situ phase analysis by a versatile miniaturized Mössbauer spectrometer
    G. Klingelhöfer
    P. Held
    B. Bernhardt
    J. Foh
    R. Teucher
    E. Kankeleit
    Hyperfine Interactions, 1998, 111 : 331 - 334
  • [10] Strategies for in-situ thin film filter monitoring with a broadband spectrometer
    Zideluns, Janis
    Lemarchand, Fabien
    Arhilger, Detlef
    Hagedorn, Arro
    Lumeau, Julien
    OPTICS EXPRESS, 2023, 31 (06) : 9339 - 9349