The diagnostic analysis of partial discharge with acoustic monitoring in GIS equipment

被引:0
|
作者
Yum, PS
Campbell, F
Eltom, AH
机构
关键词
gas insulated switching-gear; partial discharge; pattern recognition; fast Fourier transform; accelerometer;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The purpose of this study is to design a predictive monitoring system for an effective maintenance and replacement program for gas insulated switching-gear (GIS). This paper presents a new acoustic monitoring technique using partial discharge (PD) noise in GIS bus sections to detect the time-accumulated damage of insulation performance. This is accomplished using effective computer memory management techniques. The proper selection of equipment and a well-organized system configuration enhanced the analysis methods. Pattern recognition and Fast Fourier Transform has been applied for conditioning monitoring. This study showed warning patterns and recent conditions on all phases for long period. Prioritizes for maintenance and part replacement for effective management of the substations were established by this study.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [1] Location and Analysis of Abnormal Partial Discharge of 750 kV GIS Equipment
    Liu Shengchun
    Zhang Jie
    Yang Fangnan
    Yan Jianxin
    Ran Yao
    Lu Binxian
    Qian Jianhua
    2021 13TH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2021), 2021, : 83 - 85
  • [2] Analysis on Partial Discharge Localization Using UHF Combined with Acoustic Method in GIS
    Liu, Junhua
    Huang, Chengjun
    Qian, Yong
    Jiang, Xiuchen
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (03): : 1266 - 1270
  • [3] Development of portable GIS partial discharge source detection equipment
    Cui, JM
    Jai, HL
    Wang, RF
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 292 - 295
  • [4] UHF partial discharge monitoring in GIS and signal processing
    Li, ZM
    Feng, YP
    Chen, JQ
    Zhang, XZ
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 67 - 70
  • [5] Acoustic Fiber Optic Sensors for Partial Discharge Monitoring
    Qian, Sen
    Chen, Hao
    Xu, Yang
    Zhong, Lisheng
    Su, Lei
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 109 - 112
  • [6] Distributed acoustic sensing: Towards partial discharge monitoring
    Rohwetter, Philipp
    Eisermann, Rene
    Krebber, Katerina
    24TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2015, 9634
  • [7] Features and benefits of UHF partial discharge monitoring systems for GIS
    Achatz, N
    Gorablenkow, J
    Schichler, U
    Hampton, B
    Pearson, J
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 722 - 725
  • [8] Study on the monitoring technique of partial discharge of GIS by UHF method
    2005, Xi'an High Voltage Apparatus Research Institute, Beijing, China (41):
  • [9] Investigation on the acoustic emission property and critical technology for partial discharge in GIS
    Yuan, Shun
    Gongju Jishu/Tool Engineering, 1997, (02): : 7 - 10
  • [10] Estimation of partial discharge parameters in GIS using acoustic emission techniques
    Gupta, N
    Ramu, TS
    JOURNAL OF SOUND AND VIBRATION, 2001, 247 (02) : 243 - 260