Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model

被引:36
|
作者
Hofma, SH
Whelan, DMC
van Beusekom, HMM
Verdouw, PD
van der Giessen, WJ
机构
[1] Erasmus Univ, Thoraxctr, Div Cardiol, Cardiovasc Res Inst,COEUR, NL-3000 DR Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
stent; coronary arteries; vascular injury; pigs; angioplasty; histology;
D O I
10.1053/euhj.1997.0753
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims There is increased late loss in luminal diameter following long-term coronary stenting, compared with balloon angioplasty. We evaluated short-and long-term vessel wall injury after experimental implantation of two stent designs as well as balloon angioplasty and their relationship to neointimal hyperplasia. Methods and Results Wiktor stents and Palmaz-Schatz stents were implanted in normal coronary arteries of pigs (balloon/artery ratio: 0.9-1.1). In control coronary arteries, balloon angioplasty was performed. At 1, 4 and 12 weeks, the vessel injury score, neointimal thickness and inflammatory response were assessed by histology. The vessel injury score increased over time in both Wiktor and Palmaz-Schatz stents: 0.9 +/- 0.1, 1.5 +/- 0.5 and 1.7 +/- 0.6 (mean +/- SD) for Wiktor stents and 0.7 +/- 0.2, 1.0 +/- 0.1 and 1.2 +/- 0.3 for Palmaz-Schatz stents at 1, 4 and 12 weeks follow-up, respectively. No increase in injury was seen in balloon angioplasty controls. Inflammation was seen in both stented groups but was absent 12 weeks after balloon angioplasty. No strong correlation between injury and neointimal thickness was apparent. Conclusion Stents induce chronic injury in contrast to balloon angioplasty. Stent design (coil vs slotted tube) as well as inflammation may influence vessel response.
引用
收藏
页码:601 / 609
页数:9
相关论文
共 50 条
  • [1] Investigation of long-term implantation of BuMA stent in a porcine coronary model
    CHEN Ming
    WANG Xin-gang
    ZHENG Bo
    PENG Hong-yu
    Zhang Xiao-yan
    ZHANG Bin
    HUO Yong
    中华医学杂志(英文版), 2012, (22) : 4083 - 4087
  • [2] Investigation of long-term implantation of BuMA stent in a porcine coronary model
    Chen Ming
    Wang Xin-gang
    Zheng Bo
    Peng Hong-yu
    Zhang Xiao-yan
    Zhang Bin
    Huo Yong
    CHINESE MEDICAL JOURNAL, 2012, 125 (22) : 4083 - 4087
  • [3] Cilostazol improves long-term outcomes after coronary stent implantation
    Han, YL
    Wang, SL
    Li, Y
    Jing, QM
    Ma, YY
    Deng, J
    Yang, GT
    Yu, HB
    Ge, JB
    AMERICAN HEART JOURNAL, 2005, 150 (03) : 568.e1 - 568.e5
  • [4] Long-term follow-up after coronary stent implantation
    Stables, RH
    Sigwart, U
    EUROPEAN HEART JOURNAL, 1998, 19 (10) : 1424 - 1426
  • [5] Problems of long-term antiplatelet therapy after coronary stent implantation
    Kubica, Aldona
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2009, 5 (03): : 158 - 161
  • [6] Clopidogrel and long-term outcomes after stent implantation for acute coronary syndrome
    Michael, P.
    Fihn, Stephan D.
    Wang, Li
    Bryson, Chris L.
    Lowy, Elliott
    Maynard, Charles
    Magid, David J.
    Peterson, Eric D.
    Jesse, Robert L.
    Rumsfeld, John S.
    AMERICAN HEART JOURNAL, 2007, 154 (05) : 846 - 851
  • [7] Effect of fluvastatin on long-term outcome after coronary revascularization with stent implantation
    Saia, F
    de Feyter, P
    Serruys, PW
    Lemos, PA
    Arampatzis, CA
    Hendrickx, GR
    Delarche, N
    Goedhart, D
    Lesaffre, E
    Branzi, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (01): : 92 - 95
  • [8] Long-term inhibition of Rho-kinase reduces neointimal formation after stent implantation in porcine coronary arteries
    Matsumoto, Y
    Uwatoku, T
    Abe, K
    Hattori, T
    Oi, K
    Eto, Y
    Morishige, K
    Shimokawa, H
    CIRCULATION, 2002, 106 (19) : 249 - 249
  • [9] Long-term biocompatibility evaluation of a novel polymer-coated stent in a porcine coronary stent model
    Huang, YM
    Liu, XS
    Wang, L
    Li, SQ
    Verbeken, E
    De Scheerder, I
    CORONARY ARTERY DISEASE, 2003, 14 (05) : 401 - 408
  • [10] Long-term biocompatibility evaluation of a novel polymer-coated stent in a porcine coronary stent model
    Salu, KJ
    Bosmans, JM
    Huang, Y
    Liu, X
    De Scheerder, IK
    Bult, H
    Vrints, CJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 179L - 179L