IMPROVED ESTIMATION OF ULTRASOUND THERMAL STRAIN USING PULSE INVERSION HARMONIC IMAGING

被引:10
|
作者
Ding, Xuan [1 ,2 ,3 ,4 ,5 ,6 ]
Nguyen, Man M. [4 ,5 ,6 ]
James, Isaac B. [7 ]
Marra, Kacey G. [1 ,6 ,7 ,8 ]
Rubin, J. Peter [1 ,6 ,7 ,8 ]
Leers, Steven A. [9 ]
Kim, Kang [1 ,4 ,5 ,6 ,8 ]
机构
[1] Univ Pittsburgh, Sch Engn, Dept Bioengn, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Med Scientist Training Program, Pittsburgh, PA USA
[3] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
[4] Univ Pittsburgh, Sch Med, Dept Med, Ctr Ultrasound Mol Imaging & Therapeut, Pittsburgh, PA 15213 USA
[5] Univ Pittsburgh, Sch Med, Inst Heart & Vasc, Ctr Ultrasound Mol Imaging & Therapeut, Pittsburgh, PA USA
[6] Univ Pittsburgh, Med Ctr, Pittsburgh, PA USA
[7] Univ Pittsburgh, Dept Plast Surg, Pittsburgh, PA USA
[8] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA USA
[9] Univ Pittsburgh, Med Ctr, Dept Vasc Surg, Pittsburgh, PA USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2016年 / 42卷 / 05期
基金
美国国家卫生研究院;
关键词
Thermal strain imaging; Temporal strain imaging; Non-invasive ultrasound thermometry; Oil-gelatin phantom; Ultrasound clutter; Pulse inversion harmonic imaging; FORCE-INDUCED DISPLACEMENTS; TRACKING; FEASIBILITY; TRANSDUCER; CLUTTER; OIL;
D O I
10.1016/j.ultrasmedbio.2016.01.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Thermal (temporal) strain imaging (TSI) is being developed to detect the lipid-rich core of atherosclerotic plaques and presence of fatty liver disease. However, the effects of ultrasonic clutter on TSI have not been considered. In this study, we evaluated whether pulse inversion harmonic imaging (PIHI) could be used to improve estimates of thermal (temporal) strain. Using mixed castor oil-gelatin phantoms of different concentrations and artificially introduced clutter, we found that PIHI improved the signal-to-noise ratio of TSI by an average of 213% or 52.1% relative to 3.3- and 6.6-MHz imaging, respectively. In a phantom constructed using human liposuction fat in the presence of clutter, the contrast-to-noise ratio was degraded by 35.1% for PIHI compared with 62.4% and 43.7% for 3.3- and 6.6-MHz imaging, respectively. These findings were further validated using an ex vivo carotid endarterectomy sample. PIHI can be used to improve estimates of thermal (temporal) strain in the presence of clutter. (C) 2016 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1182 / 1192
页数:11
相关论文
共 50 条
  • [1] Inverted Pulse Estimation in Pulse Inversion Harmonic Imaging using Deep Learning
    Fouad, Mariam
    Schmitz, Georg
    [J]. 2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [2] Enhanced Second Harmonic Imaging using a Pulse Compression Technique Combined with Ultrasound Pulse Inversion
    Benane, Yanis Mehdi
    Bujoreanu, Denis
    Lavarello, Roberto
    Bernard, Adeline
    Cachard, Christian
    Basset, Olivier
    [J]. 2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [3] Third Harmonic Imaging using Pulse Inversion
    Rasmussen, Joachim Hee
    Du, Yigang
    Jensen, Jorgen Arendt
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2269 - 2272
  • [4] Comparison of pulse inversion and second harmonic for ultrasound contrast imaging
    Kirkhorn, J
    Frigstad, S
    Torp, H
    [J]. 2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1897 - 1901
  • [5] Pulse inversion harmonic transrectal ultrasound (TRUS) imaging of the prostate.
    Loch, T
    Lehmann, J
    Wilhelm, A
    Bach, S
    Franke, M
    Stöckle, M
    [J]. JOURNAL OF UROLOGY, 2002, 167 (04): : 361 - 362
  • [6] Improved ultrasound thermal strain imaging using frequency domain segmentation
    Ma H.
    Yin C.
    Tu J.
    Guo X.
    Zhang D.
    [J]. Shengxue Xuebao/Acta Acustica, 2024, 49 (01): : 155 - 162
  • [7] Improved detection of metastatic liver lesions using pulse inversion harmonic imaging with Levovist: A multicenter study
    Blomley, MJ
    Albrecht, T
    Wilson, SR
    Burns, PN
    Lafortune, M
    Leen, EL
    [J]. RADIOLOGY, 1999, 213P : 491 - 491
  • [8] Second harmonic inversion for ultrasound contrast harmonic imaging
    Pasovic, Mirza
    Danilouchkine, Mike
    Faez, Telli
    van Neer, Paul L. M. J.
    Cachard, Christian
    van der Steen, Antonius F. W.
    Basset, Olivier
    de Jong, Nico
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11): : 3163 - 3180
  • [9] Improvement of tissue harmonic imaging using the pulse-inversion technique
    Ma, QY
    Ma, Y
    Gong, XF
    Zhang, D
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (07): : 889 - 894
  • [10] Improved Shear Wave Motion Detection Using Pulse-Inversion Harmonic Imaging With a Phased Array Transducer
    Song, Pengfei
    Zhao, Heng
    Urban, Matthew W.
    Manduca, Armando
    Pislaru, Sorin V.
    Kinnick, Randall R.
    Pislaru, Cristina
    Greenleaf, James F.
    Chen, Shigao
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (12) : 2299 - 2310