Punching shear behaviour of flat slabs with different reinforcement schemes: openings and rectangularity effects

被引:2
|
作者
Salman, Donia [1 ]
Allouzi, Rabab [2 ]
Shatarat, Nasim [2 ]
机构
[1] Al Zaytoonah Univ Jordan, Civil & Infrastruct Engn Dept, Amman, Jordan
[2] Univ Jordan, Dept Civil Engn, Amman, Jordan
关键词
Punching shear; Opening size; Opening location; Rectangularity effect; Rectangular stirrups; Rectangular spiral stirrups; Circular spiral; PLASTIC-DAMAGE MODEL; SIZE;
D O I
10.1108/IJSI-08-2020-0079
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose The main goal is to investigate the effect of size and location of opening and column size on the punching shear strength. Openings are often needed in order to install mechanical and electrical services. This process takes away part of the concrete volume which is responsible for resisting the shear forces and any unbalanced moment. Furthermore, the application of rectangular columns in flat slabs is commonly used in practice as they provide lateral stiffness to the building. They are also utilised in garages and multi-storey buildings where these elongated cross-sectional columns reduce the effective span length between adjacent columns. Design/methodology/approach This research is a numerical-based investigation that is calibrated based on a thirteen previously tested and numerically calibrated slab specimens with no openings. A parametric study is conducted in this study to consider the effect of other parameters, which are the size and location of opening and the rectangularity ratio of column in order to evaluate their effect on the punching shear capacity. A total of 156 models are developed to study these factors. Additionally, the predicted shear carrying capacity of the simulated slabs is calculated using the ACI318-19 and Eurocode (EC2-04) equation. Findings The presence of openings reduced the punching shear capacity. The small opening's location and orientation have almost no effect except for one slab. For slabs of large openings, the presence of openings reduced the punching capacity. The punching capacity is higher when the openings are farther from the column. The numerically obtained results of slabs with rectangular columns show lower punching capacity compared to slabs of squared columns with the same length of the punching shear control perimeter. The punching capacity for all slabs is predicted by ACI318-19 and Eurocode (EC2-04) and it is found that Eurocode (EC2-04) provided a closer estimation. Originality/value The slabs considered for calibration were reinforced with four different punching shear reinforcement configurations, namely; ordinary closed rectangular stirrups, rectangular spiral stirrups, advanced rectangular spiral stirrups and circular spiral. Generally, there has been limited research on concrete flat slabs with openings in comparison with other subjects related to structural engineering (Guan, 2009) and no research on punching shear with openings of slabs reinforced with these reinforcement schemes. The available research focussed on the effects of openings on the flexural behaviour of reinforced concrete slabs includes Casadei et al. (2003), Banu et al. (2012) and Elsayed et al. (2009). In addition, experimental tests that examined slabs supported on rectangular columns are very limited.
引用
收藏
页码:589 / 612
页数:24
相关论文
共 50 条
  • [1] Punching shear behaviour of steel fibre reinforced flat slabs with punching shear reinforcement
    Landler, Josef
    Fischer, Oliver
    [J]. BETON- UND STAHLBETONBAU, 2021, 116 (05) : 348 - 359
  • [2] Punching shear strength of flat slabs with different punching reinforcement configurations
    Kamanh, M.
    Ezer, I.
    Korkmaz, H. H.
    [J]. LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 2068 - 2074
  • [3] Effects of openings on the punching shear strength of RC flat-plate slabs without shear reinforcement
    Ha, Taehun
    Lee, Myung-Ho
    Park, Jonghwan
    Kim, Dae-Jin
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2015, 24 (15): : 895 - 911
  • [4] Punching performance of flat slabs with openings accounting for the influence of moment transfer and shear reinforcement
    dos Santos, Julia Borges
    Melo, Guilherme de Sales
    Ruiz, Miguel Fernandez
    [J]. ENGINEERING STRUCTURES, 2024, 303
  • [5] Punching shear in flat slabs with open stirrups as shear reinforcement
    Siqueira, Joao P. A.
    de Melo, Guilherme Sales
    [J]. STRUCTURAL CONCRETE, 2023, 24 (02) : 2827 - 2843
  • [6] Shear band: Novel punching shear reinforcement for flat slabs
    Pilakoutas, K
    Li, X
    [J]. INNOVATION IN COMPOSITE MATERIALS AND STRUCTURES, 1997, : 35 - 45
  • [7] Punching shear resistance of flat slabs with different types of stirrup anchorages such as shear reinforcement
    de Oliveira, Victor Hugo Dalosto
    de Lima, Henrique Jorge Nery
    Melo, Guilherme Sales
    [J]. ENGINEERING STRUCTURES, 2022, 253
  • [8] Investigation of punching shear behavior of flat slabs with different types and arrangements of shear reinforcement
    Shatarat, Nasim
    Salman, Donia
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 16
  • [9] Punching strength of flat slabs with and without shear reinforcement
    Bartolac, Marko
    Damjanovic, Domagoj
    Duvnjak, Ivan
    [J]. GRADEVINAR, 2015, 67 (08): : 771 - 786
  • [10] Flat slabs without shear reinforcement: Criteria for punching
    Laboratory of Reinforced Concrete Structures, National Technical University of Athens, Greece
    [J]. Struct Eng, 2009, 23-24 (32-38):