Evaluation of a New Measurement System Combining Body Plethysmography and Electrical Impedance Tomography

被引:0
|
作者
Krueger-Ziolek, S. [1 ]
Zhao, Z. [1 ]
Moeller, K. [1 ]
机构
[1] Furtwangen Univ, Inst Tech Med, Furtwangen, Germany
关键词
body plethysmography; absolute lung volumes; electrical impedance tomography; regional lung function;
D O I
10.1515/bmt-2013-4257
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Body plethysmography is a well-established method in pulmonary function diagnosis allowing the analysis of complex and combined ventilation disorders. Lacking information of regional lung ventilation, we combined body plethysmography with electrical impedance tomography. We present and evaluate a new measurement system including both techniques. First studies indicate that a simultaneous application of both methods is feasible without major interactions. The measurement system enables the assessment of global and regional lung function at the same time, opening new possibilities in diagnosis and prognosis of pulmonary diseases.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] A Measurement System for Electrical Impedance Tomography
    Kriz, T.
    Roubal, Z.
    Rez, J.
    [J]. PIERS 2013 STOCKHOLM: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2013, : 905 - 909
  • [2] ELECTRICAL PROPERTIES OF BODY TISSUES AND IMPEDANCE PLETHYSMOGRAPHY
    SCHWAN, HP
    [J]. IRE TRANSACTIONS ON MEDICAL ELECTRONICS, 1955, (03): : 32 - 46
  • [3] Measurement of body fat distribution by using electrical impedance tomography
    Ito, Tadashi
    Yamada, Shingo
    Kazama, Hideaki
    [J]. 2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 194 - +
  • [4] Electrical impedance tomography measurement system for experimental use
    Savolainen, T
    Kaipio, JP
    Karjalainen, PA
    Vauhkonen, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (10): : 3605 - 3609
  • [5] Peripheral Vascular Measurement Using Electrical Impedance Plethysmography
    Corciova, C.
    Ciorap, R.
    Matei, R.
    Salceanu, A.
    [J]. INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2011, 36 : 136 - +
  • [6] Performance evaluation of a digital electrical impedance tomography system
    Ayati, Seyedeh Bentolhoda
    Bouazza-Marouf, Kaddour
    Kerr, David
    O'Toole, Michael
    [J]. Proceedings of the IASTED International Symposia on Imaging and Signal Processing in Health Care and Technology, ISPHT 2012, 2012, : 101 - 105
  • [7] EVALUATION OF CARDIAC PARAMETERS USING ELECTRICAL IMPEDANCE PLETHYSMOGRAPHY
    Corciova, C.
    Turnea, M.
    Matei, Daniela
    Andritoi, D.
    [J]. MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2012, 116 (03): : 927 - 932
  • [8] MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL-IMPEDANCE PLETHYSMOGRAPHY
    PORTER, JM
    SWAIN, ID
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (03): : 222 - 231
  • [9] EVALUATION OF ELECTRICAL-IMPEDANCE PLETHYSMOGRAPHY FOR NON-INVASIVE MEASUREMENT OF BLOOD-FLOW
    ARENSON, HM
    MOHAPATRA, S
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (02) : 185 - 185
  • [10] A electrical impedance tomography system
    Peng, Y
    Mo, YL
    [J]. IEEE EMBS APBME 2003, 2003, : 280 - 281