High-intensity Interstitial Ultrasound for Thermal Ablation of Focal Cancer Targets in Prostate

被引:2
|
作者
Salgaonkar, Vasant A. [1 ]
Scott, Serena [1 ,2 ]
Kurhanewicz, John [2 ,3 ]
Diederich, Chris J. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Thermal Therapy Res Grp, 1600 Divisadero St,Suite H1031, San Francisco, CA 94143 USA
[2] Univ Calif Berkeley & San Francisco, Joint Grad Grp Bioengn, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
关键词
D O I
10.1063/1.4977655
中图分类号
O59 [应用物理学];
学科分类号
摘要
Recent advances in image based techniques such as multi-parametric MRI (MP-MRI) can provide precise targeting of focal disease in the prostate. Thermal ablation of such cancer targets while avoiding rectum, urethra, neurovascular bundles (NVB) and sphincter is clinically challenging. The approach described here employs multi-element ultrasound linear arrays designed for transperineal placement within prostate. They consist of independently powered sectored tubular transducers (6.5 - 8.0 MHz) that provide spatial control of energy deposition in angle and length. Volumetric ablation strategies were investigated through patient-specific biothermal models based on Pennes bioheat transfer equation. The acoustic and heat transfer models used here have been validated in several previous simulation and experimental studies. Focal disease sites in prostate were identified through multi-parametric MR images of representative patient cases (n=3). Focal cancer lesions and critical anatomy (prostate, urethra, rectum, bladder, seminal vesicles) were manually segmented (Mimics, Materialise) and converted to 3D finite element meshes (3-Matic, Materialise). The chosen test cases consisted of patients with medium and large sized glands and models of bulk tissue ablation covered volumes in a single quadrant in posterior prostate, hemi-gland targets and "hockey-stick" targets (lesions in three quadrants). Ultrasound applicator placement was determined such that devices were positioned along the prostate periphery while avoiding surrounding anatomy. Transducer sector angles were chosen based on applicator location within limits of fabrication practicability. Thermal models were numerically solved using finite element methods (FEM) in COMSOL Multiphysics. Temperature and thermal dose distributions were calculated to determine treated volumes (> 240 CEM43C, > 52 degrees C) and safety profiles (< 10 CEM43C, < 45 degrees C) for nerve, rectal and urethral sparing. Modeling studies indicated that focal targets could be ablated with single or multiple interstitial applicators placed along the prostate periphery. In the representative cases explored during this study, thermal targets could be ablated with acoustic intensity values between 11 - 19 W/cm(2) within 6 - 15 min of sonication time. Unifocal ablation could be performed by a single directional applicator (210 degrees sectors). Hemi-gland targets were ablated by two directional applicators (210 degrees sectors). Hockey-stick ablations were performed using 3 directional applicators (2 - 210 degrees and 1 - 150 degrees).
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Focal High-Intensity Focused Ultrasound Ablation of the Prostate
    Abrams, Lauren R.
    Koch, Michael O.
    Bahler, Clinton D.
    JOURNAL OF ENDOUROLOGY, 2021, 35 : S24 - S32
  • [2] Interstitial devices for minimally invasive thermal ablation by high-intensity ultrasound
    Lafon, C.
    Melodelima, D.
    Salomir, R.
    Chapelon, J. Y.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) : 153 - 163
  • [3] High-intensity focused ultrasound focal therapy for prostate cancer
    Reddy, Deepika
    Dudderidge, Tim
    TRENDS IN UROLOGY & MENS HEALTH, 2020, 11 (03) : 15 - 18
  • [4] High-intensity focused ultrasound as focal therapy of prostate cancer
    Crouzet, Sebastien
    Rouviere, Olivier
    Martin, Xavier
    Gelet, Albert
    CURRENT OPINION IN UROLOGY, 2014, 24 (03) : 225 - 230
  • [5] Focal salvage high-intensity focused ultrasound in radiorecurrent prostate cancer
    Kanthabalan, Abi
    Peters, Max
    Van Vulpen, Marco
    McCartan, Neil
    Hindley, Richard Graham
    Emara, Amr
    Moore, Caroline M.
    Arya, Manit
    Emberton, Mark
    Ahmed, Hashim Uddin
    BJU INTERNATIONAL, 2017, 120 (02) : 246 - 256
  • [6] HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION FOR PROSTATE CANCER: INITIAL EXPERIENCE
    Manea, C. N.
    Crisan, N.
    Giurgiu, C. R.
    Oblezniuc, A.
    Urs, O.
    Coman, I.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (06) : 657 - 657
  • [7] Focal Therapy and Imaging in Prostate and Kidney Cancer: High-Intensity Focused Ultrasound Ablation of Small Renal Tumors
    Margreiter, Markus
    Marberger, Michael
    JOURNAL OF ENDOUROLOGY, 2010, 24 (05) : 745 - 748
  • [8] High-intensity focused ultrasound (HIFU) in the treatment of localized prostate cancer. From total to focal ablation
    Aboyan, I. A.
    Pakus, S. M.
    Badyan, K., I
    Hasigov, A., V
    Galstyan, A. M.
    ONKOUROLOGIYA, 2020, 16 (03): : 153 - 164
  • [9] MR-Guided High-Intensity Directional Ultrasound Ablation of Prostate Cancer
    Samuel J. Galgano
    Virginia B. Planz
    Sandeep Arora
    Soroush Rais-Bahrami
    Current Urology Reports, 2021, 22
  • [10] MR-Guided High-Intensity Directional Ultrasound Ablation of Prostate Cancer
    Galgano, Samuel J.
    Planz, Virginia B.
    Arora, Sandeep
    Rais-Bahrami, Soroush
    CURRENT UROLOGY REPORTS, 2021, 22 (01)