A 68-year-old woman had a deep brain-stimulating electrode placed for worsening of a long-standing essential tremor. There is currently no data available on the use of electroconvulsive therapy (ECT) in the presence of the deep brain stimulator (DBS), We report here the successful use of ECT in this patient with no adverse effects to the patient ol to the DBS. No special provisions were made with the ECT administration except to ensure that the stimulator was turned off prior to administration of the ECT series, and remained off through the eight treatments administered to this patient. Following the course of treatment, her mood was markedly improved, and she displayed only minor postictal confusion.
引用
收藏
页码:287 / 290
页数:4
相关论文
共 50 条
  • [1] PSYCHOMETRIC TESTING AND BRAIN-STIMULATING DRUGS
    COIRAULT, M
    POILBOUT, MF
    OUEST MEDICAL, 1977, 30 (05): : 301 - 304
  • [2] THE USE OF ECT IN A GERIATRIC PATIENT WITH A DEEP BRAIN STIMULATOR
    Bhutani, Saumya
    Scott, Jamie
    AMERICAN JOURNAL OF GERIATRIC PSYCHIATRY, 2021, 29 (04): : S36 - S37
  • [3] SELF-REGULATION OF BRAIN-STIMULATING CURRENT INTENSITY IN THE RAT
    STEIN, L
    RAY, OS
    SCIENCE, 1959, 130 (3375) : 570 - 572
  • [4] Optimal Geometry and Stimulating Mechanism of Deep-brain Electrode - Role of Electrode Contact Geometry
    Lian, Qin
    Wang, Jue
    Liu, Hongzhong
    Li, DiChen
    NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, 2008, 1048 : 355 - 358
  • [5] Intraoperative High Impedance Levels During Placement of Deep Brain Stimulating Electrode
    Lyons, Mark K.
    Neal, Matthew T.
    Patel, Naresh P.
    OPERATIVE NEUROSURGERY, 2019, 17 (06) : E264 - E266
  • [6] Commentary: Intraoperative High Impedance Levels During Placement of Deep Brain Stimulating Electrode
    Carron, Romain
    OPERATIVE NEUROSURGERY, 2019, 17 (06) : E267 - E268
  • [7] ECT IN A DEPRESSED PATIENT WITH SHUNT IN PLACE FOR NORMAL PRESSURE HYDROCEPHALUS
    TSUANG, MT
    TIDBALL, JS
    GELLER, D
    AMERICAN JOURNAL OF PSYCHIATRY, 1979, 136 (09): : 1205 - 1206
  • [8] A self-powered wearable seizure-monitoring/brain-stimulating system for potential epilepsy treatment
    Lin, Rui
    Fan, Yaowei
    Xie, Yan
    Ge, Dengyun
    Liang, Shan
    Guan, Hongye
    Chen, Meihua
    Zhang, Yan
    Xing, Lili
    Xue, Xinyu
    Zhan, Yang
    NANO ENERGY, 2023, 107
  • [9] A self-powered wearable body-detecting/brain-stimulating system for improving sports endurance performance
    Liang, Shan
    Han, Yechao
    Zhang, Wanglinhan
    Zhong, Tianyan
    Guan, Hongye
    Song, Yafeng
    Zhang, Yan
    Xing, Lili
    Xue, Xinyu
    Li, Guanglin
    Zhan, Yang
    Nano Energy, 2022, 93
  • [10] Accuracy of stimulating electrode placement in paediatric pallidal deep brain stimulation for primary and secondary dystonia
    Lumsden, Daniel E.
    Ashmore, Jonathan
    Charles-Edwards, Geoff
    Lin, Jean-Pierre
    Ashkan, Keyoumars
    Selway, Richard
    ACTA NEUROCHIRURGICA, 2013, 155 (05) : 823 - 836