Sentinel lymph node dissection in prostate cancer using superparamagnetic particles of iron oxide: early clinical experience

被引:4
|
作者
Stanik, M. [1 ]
Macik, D. [1 ]
Capak, I. [1 ]
Mareckova, N. [1 ]
Lzicarova, E. [2 ]
Dolezel, J. [1 ]
机构
[1] Masaryk Mem Canc Inst, Dept Urol Oncol, Clin Surg Oncol, Zluty Kopec 7, Brno 65653, Czech Republic
[2] Masaryk Mem Canc Inst, Dept Oncol & Expt Pathol, Zluty Kopec 7, Brno 65653, Czech Republic
关键词
Prostatic neoplasms; Lymph node excision; Sentinel lymph node biopsy; Nanoparticles; RADICAL PROSTATECTOMY; METASTASES; NANOPARTICLES; THERAPY;
D O I
10.1007/s11255-018-1903-0
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Superparamagnetic nanoparticles of iron oxide (SPION) were shown to be non-inferior to standard radioisotope tracer in breast cancer and may be used as an alternative to identify sentinel lymph nodes (SLN). The aim of this study was to assess the feasibility of sentinel lymph node dissection (SLND) using SPION in prostate cancer and to evaluate its diagnostic accuracy. Twenty patients with intermediate- and high-risk prostate cancer were prospectively enrolled in 2016. After intraprostatic injection of SPION, SLND using magnetometer was performed the following day. Extended pelvic lymph node dissection (ePLND) was added as a reference standard test. The diagnostic performance of the test were evaluated, as well as the rate of in vivo detected SLN. Surgical times of SLND and ePLND were compared using paired two-sample t test. In total, 97 SLN were detected with median 5 (IQR 3-7) per patient. Non-diagnostic rate of the procedure was 5%. In total, 19 nodal metastases were found in 5 patients, of which 12 were located in SLN. The sensitivity per patient for the whole cohort was 80% and per node 56%. If only patients with at least one detected SLN were considered, the sensitivity per patient and per node reached 100 and 82%, respectively. A median of 20 LNs (IQR 18-22) were removed by subsequent ePLND. Surgical times of SLND and ePLND differed significantly, with medians of 17 and 39 min, respectively (p < 0.001). SLND with SPION is feasible and safe in prostate cancer and the diagnostic accuracy is comparable to the published results of radioguided procedures. In open surgery, SPION may be used as an alternative tracer with its main advantage being the lack of radiation hazard.
引用
收藏
页码:1427 / 1433
页数:7
相关论文
共 50 条
  • [1] Sentinel lymph node dissection in prostate cancer using superparamagnetic particles of iron oxide: early clinical experience
    M. Staník
    D. Macík
    I. Čapák
    N. Marečková
    E. Lžíčařová
    J. Doležel
    [J]. International Urology and Nephrology, 2018, 50 : 1427 - 1433
  • [2] A Novel Method for Intraoperative Sentinel Lymph Node Detection in Prostate Cancer Patients Using Superparamagnetic Iron Oxide Nanoparticles and a Handheld Magnetometer: The Initial Clinical Experience
    Winter, Alexander
    Woenkhaus, Joachim
    Wawroschek, Friedhelm
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2014, 21 (13) : 4390 - 4396
  • [3] A Novel Method for Intraoperative Sentinel Lymph Node Detection in Prostate Cancer Patients Using Superparamagnetic Iron Oxide Nanoparticles and a Handheld Magnetometer: The Initial Clinical Experience
    Alexander Winter
    Joachim Woenkhaus
    Friedhelm Wawroschek
    [J]. Annals of Surgical Oncology, 2014, 21 : 4390 - 4396
  • [4] Superparamagnetic iron oxide (SPIO) for sentinel lymph node detection in vulvar cancer
    Del Valle, David
    Ruiz, Ruben
    Lekuona, Arantxa
    Cobas, Paloma
    Jaunarena, Ibon
    Gorostidi, Mikel
    Cespedes, Juan
    [J]. GYNECOLOGIC ONCOLOGY, 2024, 187 : 145 - 150
  • [5] Sentinel Lymph Node Biopsy in Patients with Breast Cancer Using Superparamagnetic Iron Oxide and a Magnetometer
    Shiozawa, M.
    Lefor, A.
    Hozumi, Y.
    Kurihara, K.
    Sata, N.
    Yasuda, Y.
    Kusakabe, M.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2010, 17 : S59 - S59
  • [6] Sentinel lymph node biopsy in patients with breast cancer using superparamagnetic iron oxide and a magnetometer
    Shiozawa, Mikio
    Lefor, Alan T.
    Hozumi, Yasuo
    Kurihara, Katsumi
    Sata, Naohiro
    Yasuda, Yoshikazu
    Kusakabe, Moriaki
    [J]. BREAST CANCER, 2013, 20 (03) : 223 - 229
  • [7] Sentinel lymph node biopsy in patients with breast cancer using superparamagnetic iron oxide and a magnetometer
    Mikio Shiozawa
    Alan T. Lefor
    Yasuo Hozumi
    Katsumi Kurihara
    Naohiro Sata
    Yoshikazu Yasuda
    Moriaki Kusakabe
    [J]. Breast Cancer, 2013, 20 : 223 - 229
  • [8] Initial Experience Using Superparamagnetic Iron Oxide (SPIO) for Delayed Sentinel Lymph Node Biopsy in DCIS
    Solis, Odette
    Noh, Hayne
    Sterbling, Helene
    Sipok, Arkadii
    Willey, Shawna
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2023, 30 (SUPPL 2) : S311 - S312
  • [9] Magnetic Sentinel Lymph Node Detection in Prostate Cancer after intraprostatic Injection of Superparamagnetic Iron Oxide Nanoparticles
    Winter, Alexander
    Engels, Svenja
    Kowald, Tobias
    Paulo, Tina Susanne
    Gerullis, Holger
    Chavan, Ajay
    Wawroschek, Friedhelm
    [J]. AKTUELLE UROLOGIE, 2017, 48 (02) : 132 - 139
  • [10] SENTINEL LYMPH NODE DETECTION IN VULVAR CANCER BY USING MAGNETISATION OF THE IRON OXIDE PARTICLES
    Jelenek, G.
    Feranec, R.
    Tomas, C.
    Chovanec, J.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2017, 27 : 1956 - 1956