A design of transmission-type multi-target X-ray tube based on electric field modulation

被引:5
|
作者
Zhao, Lei [1 ]
Jia, Wenbao [1 ,3 ]
Jin, Limin [1 ]
Shan, Qing [1 ,3 ]
Cheng, Can [1 ]
Zhu, Hongkui [1 ]
Hei, Daqian [2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mat Sci & Technol, Nanjing 211106, Peoples R China
[2] Lanzhou Univ, Sch Nucl Sci & Technol, Tianshui South Rd 222, Lanzhou 730000, Peoples R China
[3] Jiangsu Higher Educ Inst, Collaborat Innovat Ctr Radiat Med, Suzhou 215000, Peoples R China
关键词
X-ray tube; Multi-target; Electric field modulation; Electron beam trajectory; Optimal thickness; TARGET PARAMETERS; GUN;
D O I
10.1016/j.net.2021.03.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 10(5) V/m electric field. The focus areas are about 2 mm x 5 mm and 4 mm x 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mu m and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively. (C) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:3026 / 3034
页数:9
相关论文
共 50 条
  • [1] Development and test of a multi-target transmission X-ray tube based on the electron deflection in an electric field
    Hei, Daqian
    Jin, Limin
    Jia, Wenbao
    Zhao, Lei
    Sun, Aiyun
    Xiong, Genchao
    VACUUM, 2021, 193
  • [2] Optimization of transmission-type anode target in microfocus X-ray tube
    Zheng, Lei
    Liu, Huarong
    Sun, Buliang
    Wang, Junting
    Luo, Tingting
    Li, Yijing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2015, 35 (12): : 1443 - 1448
  • [3] Transmission-type microfocus x-ray tube using carbon nanotube field emitters
    Heo, Sung Hwan
    Ihsan, Aamir
    Cho, Sung Oh
    APPLIED PHYSICS LETTERS, 2007, 90 (18)
  • [4] Transmission-type Window of HFCVD Diamond Film for Microfocus X-ray Tube
    Zheng, Lei
    Liu, Huarong
    Wang, Junting
    Proceedings of the 2016 4th International Conference on Mechanical Materials and Manufacturing Engineering (MMME 2016), 2016, 79 : 641 - 644
  • [5] Optimization of an Anode Membrane with a Transmission-Type Target in a System of Soft X-Ray Sources for X-Ray Nanolithography
    Glagolev, P. Yu.
    Demin, G. D.
    Oreshkin, G. I.
    Chkhalo, N. I.
    Djuzhev, N. A.
    TECHNICAL PHYSICS, 2020, 65 (11) : 1709 - 1716
  • [6] Optimization of an Anode Membrane with a Transmission-Type Target in a System of Soft X-Ray Sources for X-Ray Nanolithography
    P. Yu. Glagolev
    G. D. Demin
    G. I. Oreshkin
    N. I. Chkhalo
    N. A. Djuzhev
    Technical Physics, 2020, 65 : 1709 - 1716
  • [7] Comparison of Monte Carlo tally techniques for dosimetry in a transmission-type x-ray tube
    Feng, Chen-Ju
    Lin, Chin-Hsiung
    Wu, Shu-Wei
    Luo, Shih-Yong
    Yang, Ya-Ru
    Lee, Chao-Hua
    Tseng, Shao-Chun
    Lee, Shen-Hao
    Hsu, Shih-Ming
    Wu, Chin-Hui
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (06):
  • [8] A kind of transmission-type lens using in X-ray band
    Li, Yan
    Li, Xiao-li
    Xu, Xiangyan
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [9] Transmission-type X-ray linear polarizer with perfect crystals
    Hasegawa, Y
    Ueji, Y
    Okitsu, K
    Ablett, JM
    Siddons, DP
    Amemiya, Y
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 738 - 740
  • [10] Looking Inside a Prototype Compact X-Ray Tube Comprising CNT-Based Cold Cathode and Transmission-Type Anode
    Avachat, Ashish, V
    Tucker, Wesley W.
    Giraldo, Carlos H. C.
    Pommerenke, David
    Lee, Hyoung K.
    RADIATION RESEARCH, 2020, 193 (05) : 497 - 504