Biomechanical evaluation of posterior instrumentation for lumbar burst fracture: comparison of two internal devices

被引:8
|
作者
Freslon, M.
Mosnier, T.
Gayet, L.-E.
Skalli, W.
机构
[1] Hop Jean Bernard, CHU La Miletrie, Serv Orthoped Traumatol, F-86021 Poitiers, France
[2] Ecole Natl Super Arts & Metiers, Lab Biomecan, F-75013 Paris, France
来源
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR | 2007年 / 93卷 / 03期
关键词
spine; biomechanics; burst fracture; spinal instrumentation; stability;
D O I
10.1016/S0035-1040(07)90242-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study Burst fractures generally occur due to trauma to the thoracolumbar spine. Surgery is indicated for unstable fractures. Posterior instrumentation with pedicular screws is generally proposed. In certain circumstances, hooks may be preferred due to excessive risk of insertion of the pedicular screw. The purpose of this study was to compare two posterior instrumentations, one using pedicular screws on either side of the fracture each protected by hoods and a second composed of the same pedicular screws inserted under the fracture hooks above. Material and methods Twelve spinal specimens from human cadavers composed of segments T10 to L2 were used. Range of flexion, extension, lateral inclination, and rotation were noted on T10 up to application of 7 Nm. Spinal segments were tested first intact, then in four configurations: 1) instrumented without lesion, 2) lesion simulating burst fracture of L1 without section of the interspinous ligament, 3) and with section of the interspinous ligament, and 4) with L1 corporectomy. Finally a test to rupture was performed by applying a flexion moment up to fracture. Results Mean flexion-extension of the instrumented spine was limited compared with the intact spine for both instrumentation configurations and irrespective of the lesion. The same behavior was observed for lateral inclination with less pronounced motion with the first instrumentation. For rotation, the range of motion increased clearly with the second instrumentation and this with the first lesion while with the first instrumentation, rotation amplitude remained below that of the intact spine. There was however an increase in the vertical displacement during flexion-extension for both instrumentations. For the rupture test, the mean flexion moment at rupture was 14.4 Nm (10.6-22 Nm) with no difference between the two instrumentations. Discussion This mode simulating burst fractures of the spine appears to be reproducible and more realistic than corporectomy. Attention should be taken concerning the limits of this type of study since fractures can occur for forces as small as 10.6 Nm. Thus we observed that pedicle screw configurations and also fractures produced mean ranges of motion greater than intact segments irrespective of the type of lesion simulated. However, the net increase in motion was observed during rotation movements when hooks were used, even when they were placed only below the fracture. Putting pressure on the hooks does not prevent them from slipping along the lamina. But neither of these two configurations controls the fracture gap. A vertebral reinforcement might be necessary.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [1] BIOMECHANICAL EVALUATION OF SHORT-SEGMENT POSTERIOR INSTRUMENTATION WITH CROSSLINKS IN AN UNSTABLE HUMAN BURST FRACTURE MODEL
    Wahba, George M.
    Bhatia, Nitin N.
    Lee, Thay Q.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 99 - 100
  • [2] Biomechanical evaluation of a posterior non-fusion instrumentation of the lumbar spine
    Werner Schmoelz
    Stefanie Erhart
    Stefan Unger
    Alexander C. Disch
    European Spine Journal, 2012, 21 : 939 - 945
  • [3] Biomechanical evaluation of a posterior non-fusion instrumentation of the lumbar spine
    Schmoelz, Werner
    Erhart, Stefanie
    Unger, Stefan
    Disch, Alexander C.
    EUROPEAN SPINE JOURNAL, 2012, 21 (05) : 939 - 945
  • [4] Result of Posterior Instrumentation Without Fusion in the Management of Thoracolumbar and Lumbar Unstable Burst Fracture
    Ko, Sang-Bong
    Lee, Sang-Wook
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (04): : 189 - 195
  • [5] Biomechanical investigation of lumbar hybrid stabilization in two-level posterior instrumentation
    Hegewald, Aldemar Andres
    Hartmann, Sebastian
    Keiler, Alexander
    Scheufler, Kai Michael
    Thome, Claudius
    Schmoelz, Werner
    EUROPEAN SPINE JOURNAL, 2018, 27 (08) : 1887 - 1894
  • [6] Biomechanical investigation of lumbar hybrid stabilization in two-level posterior instrumentation
    Aldemar Andres Hegewald
    Sebastian Hartmann
    Alexander Keiler
    Kai Michael Scheufler
    Claudius Thomé
    Werner Schmoelz
    European Spine Journal, 2018, 27 : 1887 - 1894
  • [7] Biomechanical Evaluation of Short-Segment Posterior Instrumentation With and Without Crosslinks in a Human Cadaveric Unstable Thoracolumbar Burst Fracture Model
    Wahba, George M.
    Bhatia, Nitin
    Bui, Christopher N. H.
    Lee, Kenneth H.
    Lee, Thay Q.
    SPINE, 2010, 35 (03) : 278 - 285
  • [8] INSTABILITY OF THE LUMBAR BURST FRACTURE AND LIMITATIONS OF TRANSPEDICULAR INSTRUMENTATION
    SLOSAR, PJ
    PATWARDHAN, AG
    LORENZ, M
    HAVEY, R
    SARTORI, M
    SPINE, 1995, 20 (13) : 1452 - 1461
  • [9] Comparison of two Types of Surgery for Thoraco-Lumbar Burst Fractures: Combined Anterior and Posterior Stabilisation vs. Posterior Instrumentation Only
    H. D. Been
    G. J. Bouma
    Acta Neurochirurgica, 1999, 141 : 349 - 357
  • [10] Comparison of two types of surgery for thoraco-lumbar burst fractures: Combined anterior and posterior stabilisation vs. posterior instrumentation only
    Been, HD
    Bouma, GJ
    ACTA NEUROCHIRURGICA, 1999, 141 (04) : 349 - 357