Contrast response for medical ultrasound analysis

被引:0
|
作者
Johnson, RK [1 ]
机构
[1] Palinurus Associates, Issaquah, WA 98029 USA
来源
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Several investigators have described the contrast performance of systems using the concept of averaged response to anechoic or weakly echoic regions. Their work has demonstrated the importance of average sidelobe level in contrast resolution. This paper discusses the use of a similar measure, called contrast response, which quantifies the ability of a system to accurately image the contrast of an anechoic region surrounded by a uniform scattering medium. The contrast response is defined as the ratio of the system output when the anechoic target is not present to the minimum output when it is present, evaluated over a range of target sizes. Contrast response analysis is useful for evaluating system operating parameters. Examples are presented which demonstrate the effects of pitch, number of active elements, aperture shading and elevation focus.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [1] Contrast response analysis for medical ultrasound imaging
    Palinurus Associates, Issaquah, United States
    IEEE Trans Ultrason Ferroelectr Freq Control, 4 (805-809):
  • [2] Contrast response analysis for medical ultrasound imaging
    Johnson, R
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (04) : 805 - 809
  • [3] LOW CONTRAST DETECTABILITY AND CONTRAST DETAIL ANALYSIS IN MEDICAL ULTRASOUND
    SMITH, SW
    WAGNER, RF
    SANDRIK, JM
    LOPEZ, H
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (03): : 164 - 173
  • [4] LOW CONTRAST DETECTABILITY AND CONTRAST DETAIL ANALYSIS IN MEDICAL ULTRASOUND
    SMITH, SW
    WAGNER, RF
    SANDRIK, JM
    LOPEZ, H
    ULTRASONIC IMAGING, 1982, 4 (02) : 188 - 188
  • [5] Predicting the acoustic response of a microbubble population for contrast imaging in medical ultrasound
    Chin, CT
    Burns, PN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08): : 1293 - 1300
  • [6] Response of contrast agents to ultrasound
    Sboros, Vassilis
    ADVANCED DRUG DELIVERY REVIEWS, 2008, 60 (10) : 1117 - 1136
  • [7] Dynamical analysis of the nonlinear response of ultrasound contrast agent microbubbles
    Carroll, James M.
    Calvisi, Michael L.
    Lauderbaugh, Leal K.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (05): : 2641 - 2649
  • [8] Lesion contrast enhancement in medical ultrasound imaging
    Stetson, PF
    Sommer, FG
    Macovski, A
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) : 416 - 425
  • [9] Response to "Contrast-enhanced intraoperative ultrasound"
    Schulz, Anselm
    ACTA RADIOLOGICA, 2013, 54 (05) : 533 - 533
  • [10] Ultrasound Contrast Agents Affect the Angiogenic Response
    Johnson, Chenara A.
    Miller, Rita J.
    O'Brien, William D., Jr.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (07) : 933 - 941