Cranial surgery and navigation with a compact Intraoperative MRI system

被引:0
|
作者
Schulder, M [1 ]
Sernas, TJ [1 ]
Carmel, PW [1 ]
机构
[1] Neurol Inst New Jersey, Dept Neurosurg, Newark, NJ 07103 USA
关键词
brain tumors; frameless stereotaxy; intraoperative magnetic resonance imaging; stereotactic surgery;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Experience with a compact unit for intraoperative magnetic resonance imaging (iMRI) and integrated surgical navigation is presented. The system, commercially known as the PoleStar N-10 (Odin Medical Technologies, Yokne'am, Israel) includes a 0.12 Tesla permanent magnet that docks under a regular OR table. A passive infrared-based optical navigation system is included and the device can be controlled by the operating neurosurgeon and staff. We have operated on 93 patients using the PoleStar N-10. Diagnoses included glioma in 27, pituitary adenoma in 19, meningioma in 15, and others in 40. Lesions were removed from the skull base in 35 patients of whom 8 had posterior fossa masses. Surgery was affected by imaging in 51% of operations. Additional lesion, not otherwise apparent, was removed in 21; in 14 other patients unnecessary dissection was avoided when the new image confirmed that the surgical goals had been achieved. Additional time incurred with use of the PoleStar diminished with increasing experience. Testing of the navigation tool confirmed its accuracy to be comparable to other "frameless stereotactic" devices, on the order of 2 mm; likewise accuracy was increased by using T1 weighted imaging with thin slices. The introduction of new, faster imaging sequences and targeting tools has helped to make the PoleStar N-10 a routine tool for intracranial surgical navigation, with the added benefit of updated imaging during the procedure.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 50 条
  • [1] Cranial surgery navigation aided by a compact intraoperative magnetic resonance imager
    Schulder, M
    Liang, D
    Carmel, PW
    JOURNAL OF NEUROSURGERY, 2001, 94 (06) : 936 - 945
  • [2] Navigation error of update navigation system based on intraoperative MRI
    Muragaki, Y
    Iseki, H
    Sugiura, M
    Suzukawa, K
    Nambu, K
    Takakura, K
    Maruyama, T
    Kubo, O
    Hori, T
    PERSPECTIVE IN IMAGE-GUIDED SURGERY, 2004, : 198 - 203
  • [3] DEVELOPMENT OF THE COMPACT MRI SYSTEM FOR INTRAOPERATIVE IMAGING
    Morita, Akio
    Sora, Shigeo
    Oguro, Toshiki
    NEURO-ONCOLOGY, 2009, 11 (06) : 881 - 881
  • [4] Stereotactic accuracy of a compact intraoperative MRI system
    Salas, Sussan
    Brimacombe, Michael
    Schulder, Michael
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2007, 85 (2-3) : 69 - 74
  • [5] Development of Hitchcock Navigation System for intraoperative open MRI
    Taniguchi, H
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1338 - 1338
  • [6] Reliable navigation registration in cranial and spine surgery based on intraoperative computed tomography
    Carl, Barbara
    Bopp, Miriam
    Sass, Benjamin
    Pojskic, Mirza
    Gjorgjevski, Marko
    Voellger, Benjamin
    Nimsky, Christopher
    NEUROSURGICAL FOCUS, 2019, 47 (06)
  • [7] Cranial surgery with an expanded compact intraoperative magnetic resonance imager - Technical note
    Schulder, M
    Salas, S
    Brimacombe, M
    Fine, P
    Catrambone, J
    Maniker, AH
    Carmel, PW
    JOURNAL OF NEUROSURGERY, 2006, 104 (04) : 611 - 617
  • [8] A system for ultrasound based intraoperative navigation in spine surgery
    Weber, PK
    Schlegel, JC
    Meiche, J
    Peter, L
    Harland, U
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1361 - 1364
  • [9] Key techniques of MRI based intraoperative neurosurgery navigation system
    Bao, Shanglian
    Zhou, Kun
    Duan, Chaijie
    Ma, Jingfeng
    Li, Shaowu
    Liu, Qi
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2007, 28 (06): : 1099 - 1103
  • [10] Development of three-dimensional navigation system updated with intraoperative MRI
    Muragaki, Y
    Suzukawa, K
    Iseki, H
    Maruyama, T
    Nambu, K
    Aramata, H
    Sugiura, M
    Naemura, K
    Hori, T
    Takakura, K
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1360 - 1360