3D-printed model and osteotomy template technique compared with conventional closing-wedge osteotomy in cubitus varus deformity

被引:6
|
作者
Li, Jin [1 ]
Wang, Jing [2 ]
Rai, Saroj [3 ]
Ze, RenHao [1 ]
Hong, Pan [1 ]
Wang, ShangYu [1 ]
Tang, Xin [1 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Orthopaed Surg, Wuhan 430022, Peoples R China
[2] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430022, Peoples R China
[3] Blue Cross Hosp, Dept Orthopaed & Trauma Surg, Kathmandu 44600, Nepal
基金
中国国家自然科学基金;
关键词
ULNAR NERVE PALSY; POSTEROLATERAL ROTATORY INSTABILITY; 3-DIMENSIONAL CORRECTIVE OSTEOTOMY; SUPRACONDYLAR HUMERAL FRACTURES; ELBOW; MANAGEMENT; FIXATION; CHILDREN;
D O I
10.1038/s41598-022-10732-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cubitus varus deformity is the most common late complication of malunited supracondylar fracture that requires corrective osteotomy and fixation. From 2009 to 2017, 40 consecutive patients with cubitus varus deformity were included. Twenty patients underwent the conventional closing-wedge osteotomy (conventional group), while the other twenty patients underwent the 3D-printed model and osteotomy template osteotomy (3D-printed template group). The functional outcome was evaluated using the Mayo Elbow Performance Index (MEPI) Score and Flynn criteria. There were no statistically significant differences were observed regarding the humerus-elbow-wrist angle and tilting angle between the two groups, both preoperatively and postoperatively at 24 months. No statistically significant differences were observed regarding the elbow ROM (127.0 +/- 4.7 degrees VS 128.9 +/- 3.8 degrees) and MEPI score (93.5 +/- 3.3 VS 94.3 +/- 4.1) between the groups. All patients were satisfied both cosmetically and functionally as per the Flynn criteria and MEPI score. The conventional osteotomy and 3D-printed model and osteotomy template techniques both met the treatment requirements of cubitus varus deformity. The 3D-printed template technique showed better osteotomy accuracy, but no significant advantage regarding the functional and cosmetic results than conventional osteotomy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] 3D-printed model and osteotomy template technique compared with conventional closing-wedge osteotomy in cubitus varus deformity
    Jin Li
    Jing Wang
    Saroj Rai
    RenHao Ze
    Pan Hong
    ShangYu Wang
    Xin Tang
    Scientific Reports, 12
  • [2] Remodeling After Lateral Closing-wedge Osteotomy in Children With Cubitus Varus
    Lee, Soon Chul
    Shim, Jong Sup
    Sul, Eun Jin
    Seo, Sung Wook
    ORTHOPEDICS, 2012, 35 (06) : E823 - E828
  • [3] OBLIQUE LATERAL CLOSING-WEDGE OSTEOTOMY FOR CUBITUS VARUS IN SKELETALLY IMMATURE PATIENTS
    Greenhill, Dustin A.
    Kozin, Scott H.
    Kwon, Michael
    Herman, Martin J.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2019, 9 (04):
  • [4] A novel method of lateral closing wedge osteotomy for cubitus varus deformity in children
    Yuxi Su
    Yan Xie
    Guoxin Nan
    BMC Surgery, 22
  • [5] A novel method of lateral closing wedge osteotomy for cubitus varus deformity in children
    Su, Yuxi
    Xie, Yan
    Nan, Guoxin
    BMC SURGERY, 2022, 22 (01)
  • [6] Lateral closed wedge osteotomy for cubitus varus deformity
    Srivastava, Amit K.
    Srivastava, D. C.
    Gaur, S. C.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2008, 42 (04) : 466 - 470
  • [7] Locking plate versus K-wires and cast fixation in lateral closing-wedge osteotomy for cubitus varus deformity
    Liu, Jianghua
    He, Youzhi
    Shi, Qiang
    Wang, Yongfu
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [8] Correction of Cubitus Varus by Supracondylar Lateral Closing Wedge Osteotomy
    Sawaqed, Issa
    BAHRAIN MEDICAL BULLETIN, 2005, 27 (04)
  • [9] Neural wedge osteotomy method of correction for cubitus varus deformity in children
    Dai, Jin
    Zhang, Wenyan
    Zou, Chengda
    Yu, Gao
    Zhao, Tantan
    Chen, Mingchao
    Gao, Zheming
    MEDICINE, 2022, 101 (34) : E30074
  • [10] Oblique closing wedge osteotomy and lateral plating for cubitus varus in adults
    Gong, Hyun Sik
    Chung, Moon Sang
    Oh, Joo Han
    Cho, Hoyune Esther
    Baek, Goo Hyun
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (04) : 899 - 906