4D MRI for the Localization of Parathyroid Adenoma: A Novel Method in Evolution

被引:29
|
作者
Merchavy, Shlomo [1 ,2 ]
Luckman, Judith [3 ]
Guindy, Michal [3 ]
Segev, Yoram [3 ]
Khafif, Avi [1 ]
机构
[1] Assuta Med Ctr, ARM Ctr Otolaryngol Head & Neck Surg, Tel Aviv, Israel
[2] Bar Ilan Univ, Fac Med Galilee, Safed, Israel
[3] Assuta Med Ctr, Dept Imaging, Tel Aviv, Israel
关键词
4D MRI; parathyroid adenoma; Sestamibi scan; ultrasound; minimally invasive surgery; PRIMARY HYPERPARATHYROIDISM; SESTAMIBI SCAN;
D O I
10.1177/0194599815618199
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The sestamibi scan (MIBI) and ultrasound (US) are used for preoperative localization of parathyroid adenoma (PTA), with sensitivity as high as 90%. We developed 4-dimensional magnetic resonance imaging (4D MRI) as a novel tool for identifying PTAs. Eleven patients with PTA were enrolled. 4D MRI from the mandible to the aortic arch was used. Optimization of the timing of image acquisition was obtained by changing dynamic and static sequences. PTAs were identified in all except 1 patient. In 9 patients, there was a complete match between the 4D MRI and the US and MIBI, as well as with the operative finding. In 1 patient, the adenoma was correctly localized by 4D MRI, in contrast to the US and MIBI scan. The sensitivity of the 4D MRI was 90% and after optimization, 100%. Specificity was 100%. We concluded that 4D MRI is a reliable technique for identification of PTAs, although more studies are needed.
引用
收藏
页码:446 / 448
页数:3
相关论文
共 50 条
  • [1] PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMA: PERFORMANCE OF 4D MRI PARATHYROID PROTOCOL
    Memeh, Kelvin Onyeka
    Palacios, Jeannine Esther
    Khan, Rihan
    Guerrero, Marlon Alex
    ENDOCRINE PRACTICE, 2019, 25 (04) : 361 - 365
  • [2] Case Series of Parathyroid Adenoma detection with 4D CT Parathyroid
    Ryan, Laura
    O'Connor, Gavin
    Melvin, Audrey
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 : S141 - S141
  • [3] The diagnostic value of 4D MRI at 3T for the localization of parathyroid adenomas
    Ozturk, Mesut
    Polat, Ahmet Veysel
    Celenk, Cetin
    Elmali, Muzaffer
    Kir, Seher
    Polat, Cafer
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 112 : 207 - 213
  • [4] A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT
    Harris, Wendy
    Wang, Chunhao
    Yin, Fang-Fang
    Cai, Jing
    Ren, Lei
    MEDICAL PHYSICS, 2018, 45 (07) : 3238 - 3245
  • [5] MEDIASTINAL PARATHYROID ADENOMA - A NEW METHOD OF LOCALIZATION
    UBHI, CS
    HARDY, JG
    PEGG, CAS
    BRITISH JOURNAL OF SURGERY, 1984, 71 (11) : 859 - 860
  • [6] Dynamic 4D MRI for Characterization of Parathyroid Adenomas: Multiparametric Analysis
    Nael, K.
    Hur, J.
    Bauer, A.
    Khan, R.
    Sepandari, A.
    Inampudi, R.
    Guerrero, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (11) : 2147 - 2152
  • [7] New methods for parathyroid imaging: Sonography, 4D CT, MRI
    Boury, Samuel
    ANNALES D ENDOCRINOLOGIE, 2015, 76 (02) : 148 - 152
  • [8] Solitary Parathyroid Adenoma Localization in Technetium Tc99m Sestamibi SPECT and Multiphase Multidetector 4D CT
    Vu, T. H.
    Schellingerhout, D.
    Guha-Thakurta, N.
    Sun, J.
    Wei, W.
    Kappadth, S. C.
    Perrier, N.
    Kim, E. E.
    Rohren, E.
    Chuang, H. H.
    Wong, F. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (01) : 142 - 149
  • [9] Recurrent hyperparathyroidism caused by a parathyroid cystic adenoma: Localization by MRI
    Department of Radiology and Surgery, University of California, San Francisco, CA, United States
    不详
    不详
    Journal of Computer Assisted Tomography, 20 (06): : 996 - 998
  • [10] Recurrent hyperparathyroidism caused by a parathyroid cystic adenoma: Localization by MRI
    Santos, E
    Higgins, CB
    Clark, O
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) : 996 - 998