Research on lamb wave wavenumber response and PZT 2D cross-shaped array based damage imaging method of aircraft composite structures

被引:0
|
作者
Qiu, Lei [1 ,2 ]
Yuan, Shenfang [1 ]
Su, Zhongqing [2 ]
Liu, Bin [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, State Key Lab Mech & Control Mech Struct, Nanjing, Jiangsu, Peoples R China
[2] Hong Kong Polytech Univ, Dept Mech Engn, Kowloon, Hong Kong, Peoples R China
[3] Air Force Serv Coll, Dept Air Force Mil Transportat, Xuzhou, Peoples R China
关键词
structural health monitoring; composite structure; damage imaging; lamb wave; spatial Fourier transform; PZT 2D cross-shaped array; SPATIAL FILTER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent decay, composite materials have widely applied to important load-bearing structures of advanced aircrafts. On-line damage monitoring of composite structure is an important research topic in the field of Structural Health Monitoring (SHM). Among the existing SHM techniques for composite structures, Lamb wave and Piezoelectric Transducer (PZT) array based damage imaging methods have been widely studied because they have the advantages of high signal-to-noise ratio and high damage sensitivity, and they can be applied to large scale structure monitoring. In this paper, a new on-line damage imaging method of composite structure which is based on Lamb wave wavenumber response and PZT 2D cross-shaped array is proposed. In this method, the PZT 2D cross-shaped array constructed by two linear PZT arrays is placed on composite structure to acquire Lamb wave damage scattering signal in spatial domain on-line. For each linear PZT array, a wavenumber-time image of the damage scattering signal can be obtained by using spatial Fourier transform and a time scanning process. Based on the two wavenumber-time images, the wavenumbers of the damage scattering signal projecting at the two arrays can be obtained. By combining with the two projection wavenumbers, the damage can be localized without blind angle. The method validation performed on a carbon fiber composite laminate plate shows a good damage localization accuracy. This method is simple but efficiency and it can be applied to on-line damage monitoring of composite structure easily.
引用
收藏
页码:190 / 201
页数:12
相关论文
共 4 条
  • [1] Damage Imaging of Aircraft Composite Structure Based on 2-D Cruciform PZT Array and Spatial-Wavenumber Filter
    Qiu, Lei
    Yuan, Shenfang
    Liu, Bin
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 570 - 576
  • [2] Lamb Waves Inspection Based on Cross-shaped Array and 2D-MUSIC Algorithm
    Liu Z.
    Zhang T.
    Su R.
    Chen H.
    He C.
    Wu B.
    Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2020, 31 (17): : 2038 - 2044
  • [3] A scanning spatial-wavenumber filter and PZT 2-D cruciform array based on-line damage imaging method of composite structure
    Qiu, Lei
    Liu, Bin
    Yuan, Shenfang
    Su, Zhongqing
    Ren, Yuanqiang
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 248 : 62 - 72
  • [4] Damage imaging for composite using Lamb wave based on minimum variance distortion-less response method
    Su, Chenhui
    Jiang, Mingshun
    Lv, Shanshan
    Zhang, Lei
    Zhang, Faye
    Lu, Shizeng
    Sui, Qingmei
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (15) : 4179 - 4186