Investigating the structure-function relationship using Goldmann V standard automated perimetry where glaucomatous damage is advanced

被引:0
|
作者
Yanagisawa, Mieko [1 ]
Murata, Hiroshi [1 ]
Matsuura, Masato [1 ]
Fujino, Yuri [1 ]
Hirasawa, Kazunori [1 ,2 ]
Asaoka, Ryo [1 ]
机构
[1] Univ Tokyo, Dept Ophthalmol, Tokyo, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Dept Rehabil, Orthopt & Visual Sci, Sagamihara, Kanagawa, Japan
基金
日本科学技术振兴机构;
关键词
glaucoma; optical coherence tomography; structure function relationship; NERVE-FIBER LAYER; OPTICAL COHERENCE TOMOGRAPHY; TEST-RETEST VARIABILITY; GANGLION-CELL COMPLEX; VISUAL-FIELD; SPATIAL SUMMATION; DIAGNOSTIC-ACCURACY; FULL THRESHOLD; SIZES III; THICKNESS;
D O I
10.1111/opo.12643
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate if the structure-function relationship between circumpapillary retinal nerve fibre layer (cpRNFL) thickness and visual field (VF) thresholds is stronger when using the Goldmann V target rather than the Goldman III target where glaucomatous damage is advanced. Methods Optical coherence tomography (OCT) and VF (Humphrey Field Analyzer 24-2 or 30-2) measurements with Goldmann III (SITA standard) and V (full-threshold) targets were carried out in 51 eyes of 51 patients with primary open angle glaucoma. The relationship between cpRNFL thicknesses in supero- and infero-temporal sectors, and VF sensitivity with the Goldmann III or V target was investigated. Result Visual field sensitivities (dB) both with the Goldmann III target and Goldmann V target showed a floor effect in the structure-function relationship against cpRNFL thickness, at approximately 60 mu m. There was no significant relationship between visual field sensitivity measured with the Goldmann V target (dB scale: p = 0.12, 1/Lambert scale: p = 0.40; linear mixed models) and cpRNFL thickness, when corresponding visual field sensitivity, measured with the Goldmann III target, was dB. Conclusion There was no improvement in the structure-function relationship using the Goldmann V target (full-threshold), compared to using the Goldmann III target (SITA standard), where glaucomatous damage was advanced.
引用
收藏
页码:441 / 450
页数:10
相关论文
共 16 条
  • [1] Comparing the Structure-Function Relationship at the Macula With Standard Automated Perimetry and Microperimetry
    Rao, Harsha L.
    Januwada, Manideepak
    Hussain, Raza S. M.
    Pillutla, Lalitha N.
    Begum, Viquar U.
    Chaitanya, Aditya
    Senthil, Sirisha
    Garudadri, Chandra S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) : 8063 - 8068
  • [2] Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
    Yanagisawa, Mieko
    Murata, Hiroshi
    Matsuura, Masato
    Fujino, Yuri
    Hirasawa, Kazunori
    Asaoka, Ryo
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2017, 6 (05):
  • [3] Structure-Function Relationship in Glaucoma Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
    Leite, M. T.
    Zangwill, L. M.
    Weinreb, R. N.
    Sample, P. A.
    Rao, H. L.
    Alencar, L. M.
    Bow, C.
    Medeiros, F. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Comparison of standard automated perimetry and short wavelength automated perimetryto evaluate the structure-function relationship in retinitis pigmentosa
    Makino, So
    Inoue, Tatsuya
    Zhou, Han Peng
    Hara, Takumi
    Murata, Hiroshi
    Asaoka, Ryo
    Obata, Ryo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] Structure-function Relationships Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
    Leite, Mauro T.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Rao, Harsha L.
    Alencar, Luciana M.
    Medeiros, Felipe A.
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 49 - 54
  • [6] Structure-Function Relationships between Macular Retinal Thickness using HRT3 and Standard Automated Perimetry
    Farantzos, George
    Kourkoutas, Dimitrios
    Paraskevopoulos, Theodoros
    Karamaounas, Aristotelis
    Karamaounas, Nicolaos
    Triantafyllopoulos, Georges
    Lygeros, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [7] Structure and function evaluation (SAFE): I. Criteria for glaucomatous visual field loss using standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP)
    Johnson, CA
    Sample, PA
    Cioffi, GA
    Liebmann, JR
    Weinreb, RN
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (02) : 177 - 185
  • [8] Exploring the Structure-Function Relationship for Perimetry Stimulus Sizes III, V and VI and OCT in Early Glaucoma
    Steudel, Sandy
    Callan, Thomas
    Lee, Gary C.
    Young, Esther
    Artes, Paul H.
    Wall, Michael
    Flanagan, John G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Structure-Function Modeling of Optical Coherence Tomography and Standard Automated Perimetry in the Retina of Patients with Autosomal Dominant Retinitis Pigmentosa
    Smith, Travis B.
    Parker, Maria
    Steinkamp, Peter N.
    Weleber, Richard G.
    Smith, Ning
    Wilson, David J.
    PLOS ONE, 2016, 11 (02):
  • [10] Structure-Function Correlations in Glaucoma Using Matrix and Standard Automated Perimetry Versus Time-Domain and Spectral-Domain OCT Devices
    Pinto, Luciano Moreira
    Costa, Elaine Fiod
    Melo, Luiz Alberto S., Jr.
    Gross, Paula Blasco
    Sato, Eduardo Toshio
    Almeida, Andrea Pereira
    Maia, Andre
    Paranhos, Augusto, Jr.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (05) : 3074 - 3080