We developed a new method for measuring gamma-ray energies in the internal calibration of a radioactive source under investigation. The measurements were carried out with the spectrometer of delayed coincidences and an optical delay line. This method allows the energies of the reference peak and the gamma-ray peak under investigation to be compared, even if they are close or coincide. The possibility of precise gamma-ray energy measurements is illustrated with Co-60 and Eu-154 isotopes.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [1] A new method for measuring γ-ray energy at the internal calibration of a radioactive source
    V. A. Morozov
    V. B. Zlokazov
    A. I. Kalinin
    V. G. Kalinnikov
    N. A. Lebedev
    N. V. Morozova
    I. N. Churin
    Instruments and Experimental Techniques, 2000, 43 : 300 - 305
  • [2] CALIBRATION OF X-RAY MEASURING METHOD OF INTERNAL-STRESSES
    PISZCZEK, J
    MECHANIK MIESIECZNIK NAUKOWO-TECHNICZNY, 1979, 52 (12): : 687 - 689
  • [3] Energy calibration using a single radioactive source
    Jabbari, N
    Rajabi, H
    Firouzabadi, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S411 - S412
  • [4] A NEW METHOD OF RADIOACTIVE STANDARD CALIBRATION
    SELIGER, HH
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1950, 45 (06): : 496 - 502
  • [5] A direct calibration method for measuring equivalent source mismatch
    Juroshek, JR
    MICROWAVE JOURNAL, 1997, 40 (10) : 106 - &
  • [6] Direct calibration method for measuring equivalent source mismatch
    Juroshek, John R.
    Microwave Journal, 1997, 40 (10):
  • [7] A new and simple calibration-independent method for measuring the beam energy of a cyclotron
    Gagnon, Katherine
    Jensen, Mikael
    Thisgaard, Helge
    Publicover, Julia
    Lapi, Suzanne
    McQuarrie, Steve A.
    Ruth, Thomas J.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (01) : 247 - 253
  • [8] A NEW METHOD FOR MEASURING ATMOSPHERIC DIFFUSION USING A RADIOACTIVE GAS EMITTED FROM A POINT SOURCE
    DRUILHET, A
    FONTAN, J
    BIASINI, H
    BLANC, D
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1968, 267 (15): : 741 - &
  • [9] Feasibility of radioactive waste drum with shell source method as calibration source for SGS device
    Xu L.-J.
    Ye H.-S.
    Zhang W.-D.
    Lin M.
    Xiao X.-F.
    Chen X.-L.
    Guo X.-Q.
    Xia W.
    Chen Y.-Z.
    Chen K.-S.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2016, 50 (03): : 558 - 564
  • [10] A METHOD FOR TIME CALIBRATION OF PET SYSTEMS USING FIXED β+ RADIOACTIVE SOURCE
    Dulski, K.
    Silarski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 195 - 200