Automated Fractional Limb Volume Measurements Improve the Precision of Birth Weight Predictions in Late Third-Trimester Fetuses

被引:18
|
作者
Mack, Lauren M. [1 ]
Kim, Sung Yoon [2 ]
Lee, Sungmin [3 ]
Sangi-Haghpeykar, Haleh [1 ]
Lee, Wesley [1 ]
机构
[1] Baylor Coll Med, Dept Obstet & Gynecol, Houston, TX 77030 USA
[2] Samsung Medison Res & Dev Ctr, Seoul, South Korea
[3] Samsung Medison Clin Res Team, Seoul, South Korea
关键词
automation; estimated fetal weight; fractional arm volume; fractional thigh volume; obstetric ultrasound; FETAL WEIGHT; 3-DIMENSIONAL ULTRASONOGRAPHY; THIGH VOLUME; NEONATAL ADIPOSITY; SONOGRAPHY; VALIDATION; ULTRASOUND; BODY;
D O I
10.7863/ultra.16.08087
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Fetal soft tissue can be assessed by using fractional limb volume as a proxy for in utero nutritional status. We investigated automated fractional limb volume for rapid estimate fetal weight assessment. Methods-Pregnant women were prospectively scanned for 2- and 3-dimensional fetal biometric measurements within 4 days of delivery. Performance of birth weight prediction models was compared: (1) Hadlock (Am J Obstet Gynecol 1985; 151:333-337; biparietal diameter, abdominal circumference, and femur diaphysis length); and (2) Lee (Ultrasound Obstet Gynecol 2009; 34:556-565; biparietal diameter, abdominal circumference, and automated fractional limb volume). Percent differences were calculated: [(estimated birth weight - actual birth weight) divided by (actual birth weight] x 100. Systematic errors (accuracy) were summarized as signed mean percent differences. Random errors (precision) were calculated as +/- 1 SD of percent differences. Results-Fifty neonates were delivered at 39.4 weeks' gestation. The Hadlock model generated the most accurate birth weight (0.31%) with a mean random error of +/- 7.9%. Despite systematic underestimations, the most precise results occurred with fractional arm volume (-9.1% +/- 5.1%) and fractional thigh (-5.2% +/- 5.2%) models. The size and distribution of these prediction errors were improved after correction for systematic errors. Conclusions-Automated fractional limb volume measurements can improve the precision of weight predictions in third-trimester fetuses. Correction factors may be necessary to adjust underestimated systematic errors when using automated fractional limb volume with prediction models that are based on manual tracing of fetal limb soft tissue borders.
引用
收藏
页码:1649 / 1655
页数:7
相关论文
共 3 条
  • [1] Angiogenic Factors and Doppler Evaluation in Normally Growing Fetuses at Routine Third-Trimester Scan: Prediction of Subsequent Low Birth Weight
    Triunfo, Stefania
    Parra-Saavedra, Miguel
    Rodriguez-Sureda, Victor
    Crovetto, Francesca
    Dominguez, Carmen
    Gratacos, Eduard
    Figueras, Francesc
    FETAL DIAGNOSIS AND THERAPY, 2016, 40 (01) : 13 - 20
  • [2] Fetal weight estimation by automated three-dimensional limb volume model in late third trimester compared to two-dimensional model: a cross-sectional prospective observational study
    Xining Wu
    Zihan Niu
    Zhonghui Xu
    Yuxin Jiang
    Yixiu Zhang
    Hua Meng
    Yunshu Ouyang
    BMC Pregnancy and Childbirth, 21
  • [3] Fetal weight estimation by automated three-dimensional limb volume model in late third trimester compared to two-dimensional model: a cross-sectional prospective observational study
    Wu, Xining
    Niu, Zihan
    Xu, Zhonghui
    Jiang, Yuxin
    Zhang, Yixiu
    Meng, Hua
    Ouyang, Yunshu
    BMC PREGNANCY AND CHILDBIRTH, 2021, 21 (01)