Long-term behaviour of square concrete-filled steel tubular columns under axial service loads

被引:34
|
作者
Kwon, S. -H.
Kim, T. -H.
Kim, Y. -Y.
Kim, J. -K.
机构
[1] Northwestern Univ, Ctr Adv Cement Based Mat, Evanston, IL 60208 USA
[2] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Taejon 305701, South Korea
[3] Chungnam Natl Univ, Taejon, South Korea
关键词
Columns; (structural);
D O I
10.1680/macr.2007.59.1.53
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental and analytical studies on the long-term behaviour of rectangular concrete-filled steel tubular (CFT) columns under central axial loading. Four loading cases are considered in this study: ( a) a load applied simultaneously on both the inner concrete and steel tube (SCE); (b) a load applied only on the inner core concrete (CE); ( c) a load applied on the steel tube and three quarters of the inner concrete (SCQ); and (d) a load applied on the steel tube and half of the inner concrete (SCH). The last two loading cases ( SCQ and SCH) simulate a diaphragm installed in the steel tube. Specimens measuring 600 mm in length were tested for the first two loading cases ( SCE and CE), and specimens of three different lengths, 600, 900 and 1200 mm, were tested for the last two loading cases in order to investigate the effect of the diaphragm size and the length of the specimen on the long-term behaviour of rectangular CFT columns. In addition to the experimental study, three-dimensional finite element models for each specimen were established and verified from a comparison of the test data and the analysis results. From the test and analysis results, a number of conclusions can be drawn. The magnitude of long-term deformation of a CFT column with a diaphragm that covers more than a half of the cross-sectional area of the inner concrete is identical with that of a column under a load applied simultaneously on the entire section of the steel tube and the inner concrete. The diaphragm confines the lateral deformation of the end surface of the column, and its influence range is limited only to the end part of the column, meaning it is limited only from the surface to a depth as long as the width of the CFT column. The confinement effect and stress variation along the longitudinal axis do not occur except in the influence range of the diaphragm. In the case of loading only at the inner concrete, the inner concrete is confined at the corner by the steel tube, and the slip between the inner concrete and the steel tube increases over time.
引用
收藏
页码:53 / 68
页数:16
相关论文
共 50 条
  • [1] Behaviour of Recycled Aggregate Concrete-Filled Steel Tubular Columns under Long-term Sustained Loads
    Yang, You-Fu
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (02) : 189 - 206
  • [2] Behaviour of square concrete-filled stiffened steel tubular stub columns under axial compression
    Yuan, Fang
    Huang, Hong
    Chen, Mengcheng
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (08) : 1878 - 1894
  • [3] Long-term behaviour under axial service loads of circular columns made from concrete filled steel tubes
    Kwon, SH
    Kim, YY
    Kim, JK
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2005, 57 (02) : 87 - 99
  • [4] Axial load behaviour of concrete-filled steel tubular columns
    De Nardin, S.
    El Debs, A. L. H. C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2007, 160 (01) : 13 - 22
  • [5] Effect of imperfection on behaviour of axial loaded square and rectangular concrete-filled steel tubular columns
    Manigandan, R.
    Kumar, Manoj
    [J]. STRUCTURES, 2024, 60
  • [6] Behaviour of concrete-filled square steel tubular columns with stiffeners under concentric compression
    Tao, Z
    Wang, ZB
    Han, LH
    [J]. PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 907 - 913
  • [7] Concrete-filled steel RHS columns subjected to long-term loads
    Han, LH
    Wei, L
    Yang, YF
    [J]. ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 583 - 590
  • [8] NONLINEAR FE ANALYSYS OF SQUARE CONCRETE-FILLED STEEL TUBULAR COLUMNS WITH INSIDE-CONSTRAINTS UNDER AXIAL LOADS
    Yu, Zhi-Wu
    He, Sa-Sa
    [J]. PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 777 - 781
  • [9] Axial behaviour of slender concrete-filled steel tube square columns strengthened with square concrete-filled steel tube jackets
    Zhu, Tao
    Liang, Hongjun
    Lu, Yiyan
    Li, Weijie
    Zhang, Hong
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (06) : 1074 - 1086
  • [10] Behaviour of CFRP confined square concrete-filled stainless steel tubular columns under uni-axial compression
    Tang, Hongyuan
    Wang, Huixiang
    Liu, Ye
    Sun, Xujie
    Huang, Xiaogang
    [J]. THIN-WALLED STRUCTURES, 2023, 183