Registration based filtering: an acceptable tool for noise reduction in left ventricular dynamic rotational angiography images?

被引:2
|
作者
Wielandts, Jean-Yves [1 ,2 ,3 ]
De Buck, Stijn [1 ,2 ,3 ]
Ector, Joris [1 ]
Nuyens, Dieter [1 ]
Maes, Frederik [2 ,3 ,4 ,5 ]
Heidbuchel, Hein [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[2] Katholieke Univ Leuven, Med Imaging Res Ctr, Leuven, Belgium
[3] UZ Leuven, Leuven, Belgium
[4] Katholieke Univ Leuven, Dept Elect Engn, ESAT PSI, Med Image Comp, Leuven, Belgium
[5] Katholieke Univ Leuven, IMinds Future Hlth Dept, Leuven, Belgium
关键词
Rotational Angiography; cardiac ablation; prospective gating; C-arm imaging; cone-beam; 4D imaging; interventional imaging; semi-automatic segmentation; left ventricle; METAL ARTIFACT REDUCTION; ABLATION;
D O I
10.1117/12.2043480
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
VT ablations could benefit from Dynamic 3D (4D) left ventricle (LV) visualization as road-map for anatomy-guided procedures. We developed a registration-based method that combines information of several cardiac phases to filter out noise and artifacts in low-dose 3D Rotational Angiography (3DRA) images. This also enables generation of accurate multi-phase surface models by semi-automatic segmentation (SAS). The method uses B-spline non-rigid inter-phase registration (IPR) and subsequent averaging of the registered 3DRA images of 4 cardiac phases, acquired with a slow atrial pacing protocol, and was validated on data from 5 porcine experiments. IPR parameter settings were optimized against manual delineations of the LVs using a composed similarity score (Q), dependent on DICE-coefficient, RMSDistance, Hausdorff (HD) and the percentage of inter-surface distances <= 3mm and <= 4mm. The latter are clinically acceptable error cut-off values. Validation was performed after SAS for varying voxel intensity thresholds (ISO), by comparison between models with and without prior use of IPR. Distances to the manual delineations at optimal ISO were reduced to <= 3mm for 95.6 +/- 2.7% and to <= 4mm for 97.1 +/- 2.0% of model surfaces. Improved quality was proven by significant mean Q-increase irrespective of ISO (7.6% at optimal ISO (95% CI 4.6-10.5, p < 0.0001)). Quality improvement was more important at suboptimal ISO values. Significant (p < 0.0001) differences were also noted in HD (-20.5%; 95% CI -12.1%-29.0%), RMSD (-28.3%; 95% CI -21.7%--35.0%) and DICE (1.7%; 95% CI 0.9%-2.6%). Generating 4D LV models proved feasible, with sufficient accuracy for clinical applications, opening the perspective of more accurate overlay and guidance during ablation in locations with high degrees of movement.
引用
收藏
页数:7
相关论文
共 17 条
  • [1] Left ventricular four-dimensional rotational angiography with low radiation dose through interphase registration
    Wielandts, Jean-Yves
    De Buck, Stijn
    Ector, Joris
    Nuyens, Dieter
    Maes, Frederik
    Heidbuchel, Hein
    EUROPACE, 2015, 17 (01): : 152 - 159
  • [2] Evaluation of left ventricular diastolic function of patients with coronary heart disease by ultrasound images on bilateral filtering image noise reduction algorithm combined with electrocardiogram
    Li, Wen
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (06) : 1699 - 1704
  • [3] Wavelet Based Non-Local Means Filtering for Speckle Noise Reduction of SAR Images
    Lee, Dea Gun
    Park, Min Jea
    Kim, Jeong Uk
    Kim, Do Yun
    Kim, Dong Wook
    Lim, Dong Hoon
    KOREAN JOURNAL OF APPLIED STATISTICS, 2010, 23 (03) : 595 - 607
  • [4] Complex Singular Value Decomposition Based Noise Reduction of Dynamic PET Images
    Wack, David S.
    Badgaiyan, Rajendra D.
    CURRENT MEDICAL IMAGING REVIEWS, 2011, 7 (02) : 113 - 117
  • [5] A Multi-Scale Fusion and Transformer Based Registration Guided Speckle Noise Reduction for OCT Images
    Tan, Zhiwei
    Shi, Fei
    Zhou, Yi
    Wang, Jingcheng
    Wang, Meng
    Peng, Yuanyuan
    Xu, Kai
    Liu, Ming
    Chen, Xinjian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (01) : 473 - 488
  • [6] Speckle Noise Reduction of Ultrasound Images Based on an Undecimated Wavelet Packet Transform Domain Nonhomomorphic Filtering
    Yan, Sheng
    Yuan, Jianping
    Liu, Minggang
    Hou, Chaohuan
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 385 - 389
  • [7] Deep learning-based noise reduction for coronary CT angiography: using four-dimensional noise-reduction images as the ground truth
    Kobayashi, Takuma
    Nishii, Tatsuya
    Umehara, Kensuke
    Ota, Junko
    Ohta, Yasutoshi
    Fukuda, Tetsuya
    Ishida, Takayuki
    ACTA RADIOLOGICA, 2023, 64 (05) : 1831 - 1840
  • [8] Noise reduction of parametric images of myocardial blood flow by filtering H215O dynamic PET images using wavelet transform
    Chung, SH
    Lee, JS
    Lee, DS
    Park, KS
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1341 - 1343
  • [9] A noise reduction method based on a statistical test of high dimensional pixel vectors for dynamic and volumetric images
    Nambu, K
    Iseki, H
    RIVISTA DI NEURORADIOLOGIA, 2005, 18 (01): : 21 - 33
  • [10] Bayesian Framework-Based Adaptive Hybrid Filtering for Speckle Noise Reduction in Ultrasound Images Via Lion Plus FireFly Algorithm
    Shabana Sulthana S L
    Sucharitha M
    Journal of Digital Imaging, 2021, 34 : 1463 - 1477