Near infrared radiometer standards

被引:8
|
作者
Eppeldauer, G
机构
来源
关键词
D O I
10.1117/12.257155
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
We are developing new detector-based radiometric scales in the near infrared to extend existing spectral radiant power calibrations(1) to spectral irradiance and radiance calibrations. High accuracy irradiance and radiance meters have been developed to realize these new detector-based radiometric scales. Mechanical, optical, and radiometric design considerations of Ge and InGaAs radiometers are discussed. Calibration principles and design considerations of the calibration setup are also described. Several results of preliminary radiometric characterizations are reported.
引用
收藏
页码:42 / 54
页数:13
相关论文
共 50 条
  • [1] A cryogenic infrared radiometer for transferal of NIST radiometric standards
    Crowther, BG
    Scott, DK
    Shumway, AL
    Williams, R
    Thurgood, VA
    [J]. HARNESSING LIGHT: OPTICAL SCIENCE AND METROLOGY AT NIST, 2001, 4450 : 168 - 179
  • [2] Traceability of the Network for Detection of the Mesospheric Change (NDMC) to radiometric standards via a Near Infrared Filter Radiometer
    van den Berg, Steven
    Dekker, Paul
    Reiniger, Max
    Gutschwager, Berndt
    Monte, Christian
    Hollandt, Jorg
    [J]. 13TH INTERNATIONAL CONFERENCE ON NEW DEVELOPMENTS AND APPLICATIONS IN OPTICAL RADIOMETRY, 2018, 972
  • [3] Calibration of advanced visible and near infrared radiometer
    Shimada, M
    Oaku, H
    Oguma, H
    Green, RO
    Miyachi, Y
    Shimoda, H
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1999, 37 (03): : 1472 - 1483
  • [4] Calibration of advanced visible and near infrared radiometer
    Shimada, Masanobu
    Oaku, Hiromi
    Oguma, Hiroyuki
    Green, Robert O.
    Miyachi, Yuji
    Shimoda, Haruhisa
    [J]. IEEE Transactions on Geoscience and Remote Sensing, 1999, 37 (3 II): : 1472 - 1483
  • [5] Calibration of near-infrared transfer standards at optical-fibre communication wavelengths by direct comparison with a cryogenic radiometer
    Corredera, P
    Campos, J
    Hernanz, ML
    Fontecha, JL
    Pons, A
    Corróns, A
    [J]. METROLOGIA, 1998, 35 (04) : 273 - 277
  • [6] Calibration of near-infrared transfer standards at optical-fibre communication wavelengths by direct comparison with a cryogenic radiometer
    Corredera, P.
    Campos, J.
    Hernanz, M.L.
    Fontecha, J.L.
    Pons, A.
    Carrons, A.
    [J]. Metrologia, 35 (04): : 273 - 277
  • [7] Calibration of a visible and near-infrared portable transfer radiometer
    Biggar, SF
    [J]. METROLOGIA, 1998, 35 (04) : 701 - 706
  • [8] Measurement of the absorptance of a cryogenic radiometer cavity in the visible and near infrared
    López, M
    Hofer, H
    Kück, S
    [J]. METROLOGIA, 2005, 42 (05) : 400 - 405
  • [9] NEAR-INFRARED DIFFUSE REFLECTANCE STANDARDS
    TKACHUK, R
    LAW, DP
    [J]. CEREAL CHEMISTRY, 1978, 55 (06) : 981 - 994
  • [10] Review of standards of near infrared spectroscopy methods
    Yang, Zengling
    Cai, Linwei
    Han, Lujia
    Fan, Xia
    Liu, Xian
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2021, 29 (06) : 313 - 320