Reproducibility of radial pulse wave analysis in healthy subjects

被引:85
|
作者
Filipovsky, J
Svobodová, V
Pecen, L
机构
[1] Charles Univ, Sch Med, Dept Internal Med 2, Pilsen, Czech Republic
[2] Acad Sci Czech Republ, Inst Comp Sci, Prague, Czech Republic
关键词
pulse wave analysis; reproducibility; aortic blood pressure; augmentation index; pressure-time indices; wave reflection;
D O I
10.1097/00004872-200018080-00007
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To determine the reproducibility of parameters estimated by pulse wave analysis (PWA), mainly of central systolic blood pressure in the aorta (CSP), central systolic pressure-time index (CSPTI, area under the systolic part of the curve in the pressure-time graph per minute), and central augmentation index (CAI, pressure peak caused by wave reflection divided by pressure peak caused by ventricular ejection). Methods In 88 healthy subjects, aged 19-53 years, radial pulse wave was registered by two investigators on separate visits in a random sequence, twice during each visit. Results Variability within and among subjects was significantly different for peripheral systolic pressure (PSP) and for all the above-mentioned parameters (P < 0.0001 by ANOVA for all). Variability within and between observers was tested by Bland-Altman plots; they did not show any trend for the variability to be dependent on the underlying mean value. PSP, CSP and CSPTI decreased significantly during one visit (by 4.6, 4.7 and 4.2%, respectively), PSP and CSP were higher at the first than at the second visit (by 2.2, 2.2%, respectively, and not significant for CSPTI), and there were also significant interobserver differences in all the three parameters as one observer measured higher values (by 2.4, 3.2 and 6.0%, respectively). CAI did not change within and between visits; the same applied to the difference between PSP and CSP since these pressures always changed in parallel. Conclusions PWA gives estimates of several parameters characterizing the pressure load of central circulation and the wave reflection. The reproducibility of CSP and CSPTI is similar to that of PSP, CAI and the difference between PSP and CSP is not influenced by order of measurement, of visit or by investigator. Therefore, CAI is a more stable parameter than PSP measured by an oscillometric device. Since these parameters may contribute to a better assessment of cardiovascular risk, PWA might be used in prospective studies. J Hypertens 2000, 18:1033-1040 (C) Lippincott Williams & Wilkins.
引用
下载
收藏
页码:1033 / 1040
页数:8
相关论文
共 50 条
  • [1] Effects of Topical Capsaicin on Carotid-Radial Pulse Wave Velocity in Healthy Subjects
    Afzal, Atif
    Bapat, Manasi
    Pettie, Thomas
    Chabbot, David
    Persits, Andrew
    Knutson, Christopher
    Salciccioli, Louis
    Lazar, Jason
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (03) : 662 - 662
  • [2] Reproducibility of regional pulse-wave velocity in uremic subjects
    Di Iorio, Biagio R.
    Cucciniello, Emanuele
    Alinei, Pietro
    Torraca, Serena
    HEMODIALYSIS INTERNATIONAL, 2010, 14 (04) : 441 - 446
  • [3] Shear wave elastography of the radial nerve in healthy subjects
    Bedewi, Mohamed A.
    Kotb, Mamdouh A.
    Aldossary, Nasser M.
    Abodonya, Ahmed M.
    Saleh, Ayman K.
    Swify, Sherine Mohamed
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (01)
  • [4] CLINICAL APPLICATION AND REPRODUCIBILITY OF CENTRAL PRESSURE AUGMENTATION USING RADIAL ARTERY PULSE WAVE ANALYSIS
    Kotecha, D.
    Pepper, J.
    Flather, M. D.
    HEART, 2013, 99 : A80 - U327
  • [5] Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    Wilkinson, IB
    Fuchs, SA
    Jansen, IM
    Spratt, JC
    Murray, GD
    Cockcroft, JR
    Webb, DJ
    JOURNAL OF HYPERTENSION, 1998, 16 (12) : 2079 - 2084
  • [6] Pulse-wave morphology and pulse-wave velocity in healthy smokers - Reproducibility and effects of examination conditions
    Frimodt-Moller, M
    Nielsen, AH
    Kamper, A
    Strandgaard, S
    JOURNAL OF HYPERTENSION, 2004, 22 : S28 - S28
  • [7] Reproducibility of pulse wave analysis and pulse wave velocity in patients with type 2 diabetes
    Laugesen, Esben
    Rossen, Niklas B.
    Hoyem, Pernille
    Christiansen, Jens S.
    Knudsen, Soren T.
    Hansen, Klavs W.
    Hansen, Troels K.
    Poulsen, Per L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2013, 73 (05): : 428 - 435
  • [8] Estimation of central pulse wave velocity from radial pulse wave analysis
    Yao, Yang
    Zhou, Shuran
    Alastruey, Jordi
    Hao, Liling
    Greenwald, Stephen E.
    Zhang, Yuelan
    Xu, Lin
    Xu, Lisheng
    Yao, Yudong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 219
  • [9] Automated hyperemia analysis software: reliability and reproducibility in healthy subjects
    Yoneda, Tsuyoshi
    Sumi, Tamaki
    Takahashi, Ayako
    Hoshikawa, Yasuhiro
    Kobayashi, Masahiko
    Fukushima, Atsuki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (01) : 1 - 7
  • [10] Automated hyperemia analysis software: reliability and reproducibility in healthy subjects
    Tsuyoshi Yoneda
    Tamaki Sumi
    Ayako Takahashi
    Yasuhiro Hoshikawa
    Masahiko Kobayashi
    Atsuki Fukushima
    Japanese Journal of Ophthalmology, 2012, 56 : 1 - 7