Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup

被引:6
|
作者
Cheng, Keding [1 ,2 ]
Sloan, Angela [1 ]
McCorrister, Stuart [1 ]
Peterson, Lorea [1 ]
Chui, Huixia [1 ,3 ]
Drebot, Mike [1 ,4 ]
Nadon, Celine [1 ,4 ]
Knox, J. David [1 ,4 ]
Wang, Gehua [1 ]
机构
[1] Publ Hlth Agcy Canada, Natl Microbiol Lab, Winnipeg, MB R3E 3R2, Canada
[2] Univ Manitoba, Fac Med, Dept Human Anat & Cell Sci, Winnipeg, MB, Canada
[3] Henan Ctr Dis Prevent & Control, Hubei, Henan Province, Peoples R China
[4] Univ Manitoba, Fac Med, Dept Med Microbiol, Winnipeg, MB, Canada
关键词
E; coli; Flagella typing; LC-MS; MS; Mass spectrometry; Quality control; ESCHERICHIA-COLI; MASS-SPECTROMETRY; BIOANALYTICAL LC/MS/MS; CARRYOVER; IDENTIFICATION; RESTRICTION; PEPTIDES; PROTEIN; GENE;
D O I
10.1002/prca.201400019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
PurposeThe need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Experimental designMotile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. ResultsLabel-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. Conclusions and clinical relevanceWith LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 45 条
  • [1] MS-H: A Novel Proteomic Approach to Isolate and Type the E. coli H Antigen Using Membrane Filtration and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Cheng, Keding
    Drebot, Mike
    McCrea, Joanne
    Peterson, Lorea
    Lee, David
    McCorrister, Stuart
    Nickel, Richard
    Gerbasi, Alyssia
    Sloan, Angela
    Janella, Debra
    Van Domselaar, Gary
    Beniac, Daniel
    Booth, Tim
    Chui, Linda
    Tabor, Helen
    Westmacott, Garrett
    Gilmour, Matthew
    Wang, Gehua
    PLOS ONE, 2013, 8 (02):
  • [2] Generic workflow for quality assessment of quantitative label-free LC-MS analysis
    Sandin, Marianne
    Krogh, Morten
    Hansson, Karin
    Levander, Fredrik
    PROTEOMICS, 2011, 11 (06) : 1114 - 1124
  • [3] Bayesian Normalization Model for Label-Free Quantitative Analysis by LC-MS
    Ranjbar, Mohammad R. Nezami
    Tadesse, Mahlet G.
    Wang, Yue
    Ressom, Habtom W.
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2015, 12 (04) : 914 - 927
  • [4] Analysis of the rat hypothalamus proteome by data-independent label-free LC-MS/MS
    Stelzhammer, Viktoria
    Amess, Bob
    Martins-de-Souza, Daniel
    Levin, Yishai
    Ozanne, Susan E.
    Martin-Gronert, Malgorzata S.
    Urday, Sebastian
    Bahn, Sabine
    Guest, Paul C.
    PROTEOMICS, 2012, 12 (22) : 3386 - 3392
  • [5] LFQuant: A label-free fast quantitative analysis tool for high-resolution LC-MS/MS proteomics data
    Zhang, Wei
    Zhang, Jiyang
    Xu, Changming
    Li, Ning
    Liu, Hui
    Ma, Jie
    Zhu, Yunping
    Xie, Hongwei
    PROTEOMICS, 2012, 12 (23-24) : 3475 - 3484
  • [6] Label-free LC-MS/MS quantitative analysis of aqueous humor from keratoconic and normal eyes
    Soria, Javier
    Villarrubia, Alberto
    Merayo-Lloves, Jesus
    Elortza, Felix
    Azkargorta, Mikel
    Alvarez de Toledo, Juan
    Rodriguez-Agirretxe, Inaki
    Suarez, Tatiana
    Acera, Arantxa
    MOLECULAR VISION, 2015, 21 : 451 - 460
  • [7] Data Processing Has Major Impact on the Outcome of Quantitative Label-Free LC-MS Analysis
    Chawade, Aakash
    Sandin, Marianne
    Teleman, Johan
    Malmstrom, Johan
    Levander, Fredrik
    JOURNAL OF PROTEOME RESEARCH, 2015, 14 (02) : 676 - 687
  • [8] The evaluation and application of a label-free quantitative proteomic strategy based on LC-ESI-MS/MS
    Chen Ming
    Ying Wan-Tao
    Fang Qin-Mei
    Sun Wei
    He Fu-Chu
    Qian Xiao-Hong
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2008, 35 (04) : 401 - 409
  • [9] Label-free analysis of mRNA capping efficiency using RNase H probes and LC-MS
    Beverly, Michael
    Dell, Amy
    Parmar, Parul
    Houghton, Leslie
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (18) : 5021 - 5030
  • [10] Label-free analysis of mRNA capping efficiency using RNase H probes and LC-MS
    Michael Beverly
    Amy Dell
    Parul Parmar
    Leslie Houghton
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5021 - 5030