CLINICAL APPLICATIONS OF VOLUMETRIC MODULATED ARC THERAPY

被引:95
|
作者
Matuszak, Martha M. [1 ]
Yan, Di [1 ]
Grills, Inga [1 ]
Martinez, Alvaro [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
Volumetric modulated arc therapy; VMAT; IMAT; WHOLE ABDOMINOPELVIC IRRADIATION; RISK ENDOMETRIAL CANCER; CONFORMAL TECHNIQUES; HELICAL TOMOTHERAPY; PELVIC IRRADIATION; RADIATION-THERAPY; 2ND CANCERS; IMRT; RADIOTHERAPY; TOXICITY;
D O I
10.1016/j.ijrobp.2009.08.032
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To present treatment planning case studies for several treatment sites for which volumetric modulated arc therapy (VMAT) could have a positive impact; and to share an initial clinical experience with VMAT for stereotactic body radiotherapy (SBRT). Methods and Materials: Four case studies are presented to show the potential benefit of VMAT compared with conformal and intensity-modulated radiotherapy (IMRT) techniques in pediatric cancer, bone marrow sparing whole-abdominopelvic irradiation (WAPI), and SBRT of the lung and spine. Details of clinical implementation of VMAT for SBRT are presented. The VMAT plans are compared with conventional techniques in terms of dosimetric quality and delivery efficiency. Results: Volumetric modulated arc therapy reduced the treatment time of spine SBRT by 37% and improved isodose conformality. Conformal and VMAT techniques for lung SBRT had similar dosimetric quality, but VMAT had improved target coverage and took 59% less time to deliver, although monitor units were increased by 5%. In a complex pediatric pelvic example, VMAT reduced treatment time by 78% and monitor units by 25% compared with IMRT. A double-isocenter VMAT technique for WAPI can spare bone marrow while maintaining good delivery efficiency. Conclusions: Volumetric modulated arc therapy is a new technology that may benefit different patient populations, including pediatric cancer patients and those undergoing concurrent chemotherapy and WAN. Volumetric modulated arc therapy has been used and shown to be beneficial for significantly improving delivery efficiency of lung and spine SBRT. (C) 2010 Elsevier Inc.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 50 条
  • [1] Clinical Volumetric Modulated introduction of Arc Therapy (VMAT)
    Dobler, B.
    Treutwein, M.
    Goetzfried, T.
    Moret, Alvarez J.
    Groeger, C.
    Haertl, P.
    Weidner, K.
    Pohl, F.
    Koelbl, O.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 105 - 106
  • [2] Clinical introduction of volumetric modulated arc therapy (VMAT)
    Wolff, D.
    Stieler, F.
    Fleckenstein, J.
    Claussen, S.
    Heim, K.
    Hermann, B.
    Steil, V.
    Wenz, F.
    Lohr, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 40 - 40
  • [3] Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT)
    Wolff, D.
    Stieler, F.
    Claussen, S.
    Fleckenstein, J.
    Heim, K.
    Hermann, B.
    Steil, V.
    Wenz, F.
    Lohr, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S734 - S735
  • [4] Principles and Clinical Application of Volumetric Modulated Arc Therapy
    Popple, R.
    Shepard, D.
    Yu, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3333 - +
  • [5] Clinical Implementation and Commission of Volumetric Modulated Arc Therapy
    Wu, Q. J.
    McMahon, R.
    Chang, Z.
    Zhuang, T.
    O'Daniel, J.
    Yoo, S.
    Zhu, X.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3858 - 3858
  • [8] CLINICAL IMPLEMENTATION OF VOLUMETRIC INTENSITY MODULATED ARC THERAPY (VMAT)
    McNair, H.
    Aitken, A.
    Bedford, J.
    Brock, J.
    Helyer, S.
    Warrington, A.
    Brada, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S50 - S50
  • [9] Paraspinal volumetric modulated arc therapy
    Bedford, J. L.
    Convery, H. M.
    Hansen, V. N.
    Saran, F. H.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : 1128 - 1133
  • [10] Clinical Implementation and dosimetric Verification of Volumetric Modulated Arc Therapy (VMAT)
    Wolff, D.
    Barrois, V
    Vogelgesang, L.
    Bosold, S.
    Tsogtbaatar, L.
    Sparenberg, J.
    Engenhart-Cabillic, R.
    Zink, K.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 157 - 157