An analysis of the time delay and relationship between external sensor signals and internal organ motion for respiratory gated radiotherapy

被引:0
|
作者
Chung, J.
Lee, J.
Kim, J.
Yoon, J.
Jung, W.
Suh, T.
机构
[1] Seoul Natl Univ, Bundang Hosp, Seoul, South Korea
[2] Konkuk Univ Hosp, Seoul, South Korea
[3] Catholic Univ, Seoul, South Korea
关键词
D O I
10.1118/1.2760582
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate the delay time and relationship between external signals and internal organ motion for respiratory gated radiotherapy Methods and Materials: In 5 patients, we measured the external respiratory sensor signals, which included respiratory volume, respiratory temperature, and abdominal displacement with three sensors (spirometry, belt‐transducer, and thermistor), and internal organ motion with the fluoroscopy. To evaluate the relationship of the internal organ and external sensor signals, a linear least‐square fit was performed with two signals, and the correlation coefficient (R values) was determined. In order to test the presence of a time‐varying phase relationship, a unique cross‐correlation of the respiratory motion signals and internal organ motion data were performed. Cross‐correlation function (CCF) analysis allows for the identification and estimation of a phase or time delay in two related signals. Results: The correlation coefficient of respiratory signal showed that the internal organ motion to abdominal displacement by piezo respiratory belt‐transducer exhibited high correlation of 0.94 (range 0.98–0.85) with a standard deviation of about 0.06, whereas the respiratory volume and temperature to organ motion was a poor correlation (average 0.70, 0.71). The result of respiratory volume and temperature shows the influence of the phase shift, regarding time delay of 0.2 – 0.4 s. Two sensor signals considered the time delay correction generally correlated well with internal organ motion. Conclusion: This correlation in this study can be used to predict internal organ motion, based on the external sensor signals. If the time delay of external sensor signals was corrected carefully, the use of the respiratory sensor would improve the accuracy for respiratory gated radiotherapy. Thus, it is expected that the respiratory sensors will come into wider use. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2386 / 2386
页数:1
相关论文
共 50 条
  • [1] Multi-sensor measurement of external movement to improve correlation between external marker and internal motion for respiratory motion management during radiotherapy
    Christensen, J. D.
    Tai, A.
    Li, X. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S716 - S717
  • [2] Tracking of respiratory motion by using the gyroscope sensor for respiratory gated radiotherapy
    Sung, J.
    Chung, W.
    Yoon, M.
    Kim, D.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S913 - S914
  • [3] Correlation of target movement, diaphragm motion and external sensor signals for respiratory-gated hepatoma radiotherapy using TACE as a target indicator
    Lee, C
    Hong, J
    Ho, C
    Chao, T
    MEDICAL PHYSICS, 2005, 32 (06) : 1945 - 1945
  • [4] Synchronous monitoring of external/internal respiratory motion: validity of respiration-gated radiotherapy for liver tumors
    Nishioka, Takeshi
    Nishioka, Seiko
    Kawahara, Masaki
    Tanaka, Shigeru
    Shirato, Hiroki
    Nishi, Ken
    Hiromura, Tadao
    JAPANESE JOURNAL OF RADIOLOGY, 2009, 27 (07) : 285 - 289
  • [5] Synchronous monitoring of external/internal respiratory motion: validity of respiration-gated radiotherapy for liver tumors
    Takeshi Nishioka
    Seiko Nishioka
    Masaki Kawahara
    Shigeru Tanaka
    Hiroki Shirato
    Ken Nishi
    Tadao Hiromura
    Japanese Journal of Radiology, 2009, 27 : 285 - 289
  • [6] Residual motion of lung tumors in gated radiotherapy with external respiratory surrogates
    Berbeco, R
    Nishioka, S
    Shirato, H
    Chen, G
    Jiang, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2124 - 2124
  • [7] Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates
    Berbeco, RI
    Nishioka, S
    Shirato, H
    Chen, GTY
    Jiang, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3655 - 3667
  • [8] INVESTIGATION OF RELATION BETWEEN INTERNAL-EXTERNAL MARKERS FOR RESPIRATORY MOTION CONPENSATION IN RADIOTHERAPY
    Uzupyte, Ruta
    Visockaite, Evelina
    Krilavicius, Tomas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 130 - 133
  • [9] Correlation identification between internal/external motion signals
    Wu, Huanmei
    Zhao, Qingya
    Berbeco, Ross
    Nishioka, Seiko
    Shirato, Hiroki
    Jiang, Steve B.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [10] Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy
    Tsunashima, Y
    Sakae, T
    Shioyama, Y
    Kagei, K
    Terunuma, T
    Nohtomi, A
    Akine, Y
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 951 - 958