EXPERIMENTAL INVESTIGATION ON FLOW AND HEAT TRANSFER FOR COOLING FLUSH-MOUNTED RIBBONS IN A CHANNEL Application of an Electrohydrodinamics Active Enhancement Method

被引:0
|
作者
Aalmi Nia, Amin [1 ]
Campo, Antonio [2 ]
机构
[1] Azarbaijan Shahid Madani Univ, Dept Mech Engn, Tabriz, Iran
[2] Univ Texas San Antonio, Dept Mech Engn, San Antonio, TX USA
来源
THERMAL SCIENCE | 2016年 / 20卷 / 02期
关键词
convective heat transfer; duct flow; flush-mounted ribbons; heat transfer enhancement; electrohydrodynamics; corona wind; SIMULATION; RIBS;
D O I
10.2298/TSCI130518150A
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study, the heat transfer enhancement of a bundle of flush-mounted ribbons placed on the floor of a rectangular duct was investigated experimentally. The flush-mounted ribbons act as heat sources and the cooling happens with air. The air flow was 2-D, steady, viscous, and incompressible under either laminar (500 <= Re-Dh, <= 2000) and turbulent (2000 <= Re-Dh 4500) conditions. The hydrodynamics and heat transfer behavior of the air flow was studied by means of an active method with application of corona wind. The state-of-the-art of this work revolves around an experimental investigation of an electrohydrodynamics active method and heat transfer enhancement from the surfaces of the flush-mounted ribbons. Due to the intricacies of the required experiment, a special apparatus needed to be designed and constructed.
引用
收藏
页码:505 / 516
页数:12
相关论文
共 50 条
  • [1] Experimental study on EHD heat transfer enhancement from flush-mounted ribbons with different arrangements of wire electrodes in a channel
    Nia, Amin Alami
    Campo, Antonio
    HEAT AND MASS TRANSFER, 2016, 52 (12) : 2823 - 2831
  • [2] Experimental study on EHD heat transfer enhancement from flush-mounted ribbons with different arrangements of wire electrodes in a channel
    Amin Alami nia
    Antonio Campo
    Heat and Mass Transfer, 2016, 52 : 2823 - 2831
  • [3] Three-dimensional convective cooling in a vertical channel with flush-mounted heat sources
    Gunes, H
    Liakopoulos, A
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (05) : 791 - 808
  • [4] Experimental Optimization of Passive Cooling of a Heat Source Array Flush-Mounted on a Vertical Plate
    Baudoin, Antoine
    Saury, Didier
    Zhu, Bo
    Bostrom, Cecilia
    ENERGIES, 2016, 9 (11)
  • [5] Heat transfer and pressure loss characterization in a channel with discrete flush-mounted and protruding heat sources
    Wang, Y
    Vafai, K
    EXPERIMENTAL HEAT TRANSFER, 1999, 12 (01) : 1 - 16
  • [6] An experimental study on forced convection heat transfer from flush-mounted discrete heat sources
    Tso, C.P.
    Xu, G.P.
    Tou, K.W.
    Journal of Heat Transfer, 1999, 121 (02): : 326 - 332
  • [7] HEAT TRANSFER FROM TWO DISCRETE FLUSH-MOUNTED HEATERS SUBJECTED TO LAMINAR PULSATING AIR FLOW IN A CHANNEL
    Akdag, Unal
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2012, 36 (04) : 357 - 372
  • [8] An experimental study an forced convection heat transfer from flush-mounted discrete heat sources
    Tso, CP
    Xu, GP
    Tou, KW
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1999, 121 (02): : 326 - 332
  • [9] Experimental Investigation on Heat Transfer Enhancement from a Channel Mounted with Staggered Blocks
    Sivasubramanian, M.
    Kanna, P. Rajesh
    Uthayakumar, M.
    Ganesan, P.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2015, 40 (04) : 1123 - 1139
  • [10] Experimental Investigation on Heat Transfer Enhancement from a Channel Mounted with Staggered Blocks
    M. Sivasubramanian
    P. Rajesh Kanna
    M. Uthayakumar
    P. Ganesan
    Arabian Journal for Science and Engineering, 2015, 40 : 1123 - 1139