Comparative Evaluation of Two Different Types of Abutments in Relation to Post-prosthetic Bone Resorption and Periodontal Pocket Depth: A Randomized Controlled Clinical Trial With a One-Year Follow-Up

被引:0
|
作者
Almodalal, Mohammad Anas [1 ]
Morad, Mhd. Luai [1 ]
Hajeer, Mohammad Y. [2 ]
Harfouche, Munir [3 ]
机构
[1] Univ Damascus, Dept Fixed Prosthodont, Fac Dent, Damascus, Syria
[2] Univ Damascus, Dept Orthodont, Fac Dent, Damascus, Syria
[3] Univ Damascus, Dept Oral & Maxillofacial Surg, Fac Dent, Damascus, Syria
关键词
depth of the periodontal pocket; bone loss; 3d laser printer; lost wax technique; molded abutment; printed abutment; standard abutment; dental implant; INTERNAL FIT; IMPLANT ABUTMENTS; CROWNS;
D O I
10.7759/cureus.25807
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim: in the past few years, the number of studies conducted on the designs of abutments and related materials has increased. The restoration is performed over the implant using prefabricated standard abutments. Due to the problems encountered in relation to bone resorption following restoration, other types of abutment designs have been introduced in the dental field such as molded abutments usually fabricated by the lost-wax technique and computer-designed abutments produced by three-dimensional (3D) printing technology. The aim of this study was to compare the clinical performance of molded abutments and computer-designed 3D printed abutments in terms of the bone loss around the implant and the depth of periodontal pockets in a one-year observation period. Methods: The research sample consisted of 32 dental implants for patients who required two adjacent implants. Patients were randomly allocated into two groups: in the first group, the patients received molded abutments, whereas, in the second group, the patients received 3D printed abutments with an allocation ratio of 1:1. In the molded abutment group, the plastic abutments were waxed and poured using the Ni-Cr mixture in the lost-wax technique, while in the printed abutment group, the abutments were designed by a computer program and printed using the Cr-Co mixture employing a 3D laser printer. The bone level and pocket depth around the implant were evaluated at 3, 6, and 12 months following cementation. Results: After one year, there were significant differences in the bone resorption mean values between the 3D laser-printed abutment group (0.43 +/- 0.11) and molded abutment group (0.54 +/- 0.11). In addition, there were significant differences in the mean values of probing depth between the 3D laser-printed abutment group (3.39 +/- 0.12) and molded abutment group (3.53 +/- 0.08). Therefore, the 3D laser-printed abutment was slightly better and had a lower bone loss degree than the molded abutment. Conclusion: Within the limitations of the current work, the mean bone resorption for both types of abutments was within the normal limits. However, the implants that were restored using the printed abutments had less bone resorption than those restored using the molded abutments.
引用
收藏
页数:14
相关论文
共 27 条
  • [1] One-year follow-up of two exercise interventions for the management of patients with ankylosing spondylitis -: A randomized controlled trial
    Fernández-de-las-Peñas, C
    Alonso-Blanco, C
    Alguacil-Diego, IM
    Miangolarra-Page, JC
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2006, 85 (07) : 559 - 567
  • [2] COMPARISON OF THE EFFECTIVENESS OF FUNCTIONAL AND NIGHT SPLINT FOR RHIZARTHROSIS: ONE-YEAR FOLLOW-UP OF A CONTROLLED, RANDOMIZED, BLINDED CLINICAL TRIAL
    Silva, F. C.
    Adolph, S. M. M.
    da Silva, R. V. T.
    Natour, J.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1478 - 1479
  • [3] EFFECTIVENESS OF PHYSIOTHERAPY AND COSTS IN PATIENTS WITH CLINICAL SIGNS OF SHOULDER IMPINGEMENT SYNDROME: ONE-YEAR FOLLOW-UP OF A RANDOMIZED CONTROLLED TRIAL
    Kromer, Thilo O.
    de Bie, Rob A.
    Bastiaenen, Caroline H. G.
    JOURNAL OF REHABILITATION MEDICINE, 2014, 46 (10) : 1029 - 1036
  • [4] Randomized Clinical Trial of ART Class II Restorations Using Two Glass Ionomer Cements: One-Year Follow-Up
    Condeixa de Franca Lopes, Celia Maria
    Schubert, Edward Werner
    Martins, Alessandra Souza
    Loguercio, Alessandro Dourado
    Reis, Alessandra
    Rodrigues Chibinski, Ana Claudia
    Wambier, Denise Stadler
    PEDIATRIC DENTISTRY, 2018, 40 (02) : 98 - 104
  • [5] Marginal bone loss at implants with different surface characteristics - A 20-year follow-up of a randomized controlled clinical trial
    Donati, Mauro
    Ekestubbe, Annika
    Lindhe, Jan
    Wennstrom, Jan L.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) : 480 - 487
  • [6] Two-stage integrated care versus antipsychotic medication alone on outcomes of schizophrenia: One-year randomized controlled trial and follow-up
    She, Shenglin
    Deng, Yongjie
    Chen, Yuwei
    Wu, Chao
    Yi, Wenying
    Lu, Xiaodan
    Chen, Xinrui
    Li, Juanhua
    Li, Ruikeng
    Zhang, Jie
    Xiao, Di
    Wu, Haibo
    Ning, Yuping
    Zheng, Yingjun
    PSYCHIATRY RESEARCH, 2017, 254 : 164 - 172
  • [7] The effectiveness of an individually tailored oral health educational programme on oral hygiene behaviour in patients with periodontal disease: a blinded randomized-controlled clinical trial (one-year follow-up)
    Jonsson, B.
    Ohrn, K.
    Oscarson, N.
    Lindberg, P.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2009, 36 (12) : 1025 - 1034
  • [8] Lateral ridge augmentation with two different ratios of deproteinized bovine bone and autogenous bone: A 2-year follow-up of a randomized and controlled trial
    Mordenfeld, Arne
    Aludden, Hanna
    Starch-Jensen, Thomas
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 884 - 894
  • [9] Clinical outcomes following atrophic alveolar ridge reconstruction using collagenated xenogeneic bone block or autogenous bone block: One-year follow-up of a randomized controlled clinical
    Romito, Giuseppe Alexandre
    Fonseca, Marcelo Augusto
    Soares, Herbert Horiuti
    de Oliveira Lazarin, Rafael
    Sapata, Vitor Marques
    Nishyama, Roger
    Conde, Marina Clemente
    Hammerle, Christoph Hans Franz
    Schwarz, Frank
    Villar, Cristina Cunha
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2024, 51 (01) : 14 - 23
  • [10] Clinical Outcome of Three Different Types of Posterior All-Ceramic Crowns. A 3-Year Follow-up of a Multicenter, Randomized, Controlled Clinical Trial
    Minh Le
    Dirawi, Wissam
    Papia, Evaggelia
    Larsson, Christel
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (05) : 546 - +