Simultaneous determination of docetaxel and ketoconazole in rat plasma by liquid chromatography/electrospray ionization tandem mass spectrometry

被引:32
|
作者
Huang, Qing
Wang, Guang-Ji [1 ]
Sun, Jian-Guo
Hu, Xiao-Lin
Lu, Yi-Hong
Zhang, Qian
机构
[1] China Pharmaceut Univ, Key Lab Drug Metab & Pharmacokinet, Nanjing 210038, Peoples R China
[2] Jiangsu Inst Drug Control, Nanjing 210008, Peoples R China
关键词
D O I
10.1002/rcm.2903
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C-18 analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3 -> 549.1 (m/z) for docetaxel, 531.2 -> 489.3 (m/z) for ketoconazole, and 876.7 -> 307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published). Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:1009 / 1018
页数:10
相关论文
共 50 条
  • [1] Determination of anastrozole in rat plasma by liquid chromatography-tandem mass spectrometry with electrospray ionization
    Yasin, M.
    [J]. JOURNAL OF PHARMACY AND PHARMACOLOGY, 2005, 57 : S80 - S81
  • [2] Simultaneous Determination of Eight Ginsenosides in Rat Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry: Application to Their Pharmacokinetics
    Ma, Li-Yuan
    Zhang, You-Bo
    Zhou, Qi-Le
    Yang, Yan-Fang
    Yang, Xiu-Wei
    [J]. MOLECULES, 2015, 20 (12) : 21597 - 21608
  • [3] Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry
    Kravtsova, Oxana Yu.
    Paramonov, Sergey A.
    Vasilevich, Natalya I.
    Kazyulkin, Denis N.
    Vlasova, Ekaterina
    Engsig, Michael
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1609 - 1614
  • [4] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    [J]. JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [5] Determination of moxifloxacin in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) : 961 - 968
  • [6] Simultaneous quantification of oleuropein and its metabolites in rat plasma by liquid chromatography electrospray ionization tandem mass spectrometry
    Bazoti, Fotini N.
    Gikas, Evangelos
    Tsarbopoulos, Anthony
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (05) : 506 - 515
  • [7] Determination of Ranolazine in Rat Plasma by Liquid Chromatography–Electrospray Ionization Mass Spectrometry
    J. Zhong
    X. Q. Liu
    Y. Chen
    X. P. Zhao
    Y. S. Wang
    G. J. Wang
    [J]. Chromatographia, 2006, 63 : 123 - 127
  • [8] Simultaneous determination of azilsartan and chlorthalidone in rat and human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Ramakrishna, Rachumallu
    Puttrevu, Santosh Kumar
    Bhateria, Manisha
    Bala, Veenu
    Sharma, Vishnu L.
    Bhatta, Rabi Sankar
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 185 - 197
  • [9] Determination of bencycloquidium bromide in dog plasma by liquid chromatography with electrospray ionization tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Dong, Xinwei
    Xie, Qiangmin
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (05) : 490 - 496
  • [10] Determination of bulleyaconitine A in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Weng, WY
    Xu, HN
    Huang, JM
    Wang, GQ
    Shen, T
    Zhang, JF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 315 - 320