Study on Different Dimensions of C-type Corona Rings in 400 kV Insulator Strings Based on FEM Analysis of Electric Field Distribution

被引:0
|
作者
Sardast, Roghieh [1 ]
Faghihi, Faramarz [1 ]
Vakilian, Mandi [2 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Elect Engn, Tehran, Iran
[2] Sharif Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
insulator string; corona ring; potential distribution; electric field distribution; FEM;
D O I
10.1109/iraniancee.2019.8786424
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents analysis of electric field distribution and optimization of C-type corona rings for 400 kV V-insulator strings composed of ceramic insulator units which are the most common configuration of overhead transmission lines. These strings are equipped with corona rings to enhance the insulation performance regarding to the effect of these rings on the insulation function and potential and electric field distribution. 3D field simulations are performed for the C-type of corona rings with different dimensions by software based on FEM analysis.
引用
收藏
页码:673 / 678
页数:6
相关论文
共 8 条
  • [1] Effects of Corona Ring Dimensions on the Electric Field Distribution on 132 kV Glass Insulator
    Hassanvand, A.
    Illias, H. A.
    Mokhlis, H.
    Bakar, A. H. A.
    2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 248 - 251
  • [2] Investigation of Electric Field Distribution on A C Composite 230kV Insulator Using Corona Ring
    Kalimurugan, M. S.
    Sankar, S. Arun
    Iruthayarajan, M. Willjuice
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 142 - 147
  • [3] FEM analysis of elliptical void in insulator of GIS compartment based on electric field distribution
    Ghasemzadeh, Mohamad Reza
    Faghihi, Faramarz
    Mozafari, Seyed Babak
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [4] Effects of Corona Ring Design and its Location on Electric Field and Potential Distribution Along 400kV and 1000kV Contaminated Insulator String
    Hosseini, S. M. Hassan
    Samadzadeh, H.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (01): : 3408 - 3413
  • [5] FEM analysis of electric field distribution for polymeric insulator under different configuration of non-uniform pollution
    Ghiasi, Zahra
    Faghihi, Faramarz
    Shayegani-Akmal, Amir Abbas
    Moradi CheshmehBeigi, Hassan
    Rouzbehi, Kumars
    ELECTRICAL ENGINEERING, 2021, 103 (06) : 2799 - 2808
  • [6] FEM analysis of electric field distribution for polymeric insulator under different configuration of non-uniform pollution
    Zahra Ghiasi
    Faramarz Faghihi
    Amir Abbas Shayegani-Akmal
    Hassan Moradi CheshmehBeigi
    Kumars Rouzbehi
    Electrical Engineering, 2021, 103 : 2799 - 2808
  • [7] Calculation of Electric Field and Voltage Distribution along Glass Insulator String and Optimum Design of its Grading Rings for 1000kV a.c. UHV Transmission Lines
    Zhao, Yanzhen
    Li, Hualiang
    Ma, Xikui
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 866 - 869
  • [8] Study on the Electric Field Distribution Characteristics of 66 kV Dry-Type Transformer Based on Functional Graded Material (FGM) Treatment
    Qiao, Xinhan
    Zhu, Zishang
    Zhang, Yuchang
    Yu, Le
    Zhang, Dongdong
    Zhang, Jianwen
    Di, Xinxi
    Wang, Yijiao
    Zeng, Wengtian
    ENERGIES, 2024, 17 (22)