Do Ultraviolet Air Disinfection Units Reduce Contamination by Particulates in Total Knee Replacement Procedures?

被引:4
|
作者
Jones, Hugh L. [1 ]
Braly, Houston L. [2 ]
Parsley, Brian S. [3 ]
Gonzalez, Jasmine L. [4 ]
Ausborn, Valerie A. M. [4 ]
Noble, Philip C. [1 ]
机构
[1] Univ Texas, Ctr Orthopaed Res Innovat & Training, McGovern Med Sch, Dept Orthoped Surg, 5410 W Loop S,Suite 1300, Bellaire, TX 77401 USA
[2] Texas Orthoped Hosp, Houston, TX USA
[3] Houston Methodist Hosp, Dept Orthoped, Houston, TX 77030 USA
[4] Mem Hermann Orthopaed & Spine Hosp, Bellaire, TX USA
来源
JOURNAL OF ARTHROPLASTY | 2022年 / 37卷 / 06期
关键词
infection; infection prevention; perioperative care; airborne contaminates; surgical site infection; perioperative prevention; ultraviolet sterilization; knee arthroplasty; FLOW;
D O I
10.1016/j.arth.2022.02.070
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Prosthetic joint infections have become the leading cause of joint replacement failure. The primary sources of contamination are skin flora and bacteria from airborne particles. Portable ultraviolet air disinfection units are used in the Operating Room (OR) to prevent contamination from airborne particles; however, their effectiveness is not proven. The purpose of this study was to compare the rate of contamination of sites with and without Ultraviolet (UV) air disinfection units during active surgeries. Methods: Sedimentation rates of viable particles were measured during 40 primary TKA procedures. Half of the procedures were performed with ultraviolet air disinfection units. Air-borne particles were collected on nitrocellulose membranes at 5 locations within the OR. After incubation, all microbial colonies were counted and the sedimentation rates were reported in CFUs/m(2)/hr. 10 additional trials were performed in an empty OR with no staff present. Results: The average contamination rate of all sites was 22 +/- 1.1 CFUs/m(2)/hr in the empty OR vs. 21.3 +/- 4.6 CFUs/m(2)/hr with UV units and 20.3 +/- 4.9 CFUs/m(2)/hr without (P = .03, P = .03, P = .964). Viable contaminates were found in the sterile field in 25% of UV cases vs 45% non-UV. These differences were not statistically significant. There were differences found however, according to the number of staff in the room (6 vs 7 staff: P = .036, 6 vs 8 staff: P = .004). Conclusion: There was no statistical difference in contamination rate with the usage or non-usage of UV units. These 40 cases shows that the largest variables affecting the contamination rate were the number of staff present and size of the OR. (C) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:S301 / S305
页数:5
相关论文
共 50 条
  • [1] ULTRAVIOLET-RADIATION AND AIR CONTAMINATION DURING TOTAL HIP-REPLACEMENT
    CARLSSON, AS
    NILSSON, B
    WALDER, MH
    OSTERBERG, K
    JOURNAL OF HOSPITAL INFECTION, 1986, 7 (02) : 176 - 184
  • [2] ULTRAVIOLET-RADIATION AND AIR CONTAMINATION DURING TOTAL HIP-REPLACEMENT
    CARLSSON, AS
    WALDER, M
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (04): : 453 - 454
  • [3] In-Room Ultraviolet Air Filtration Units Reduce Airborne Particles During Total Joint Arthroplasty
    Anis, Hiba K.
    Curtis, Gannon L.
    Klika, Alison K.
    Piuzzi, Nicolas S.
    Otiso, Joshua
    Richter, Sandra S.
    Barsoum, Wael K.
    Higuera, Carlos A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (02) : 431 - 437
  • [4] Reduction of Particles in the Operating Room Using Ultraviolet Air Disinfection and Recirculation Units
    Curtis, Gannon L.
    Faour, Mhamad
    Jawad, Michael
    Klika, Alison K.
    Barsoum, Wael K.
    Higuera, Carlos A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : S196 - S200
  • [5] TOTAL KNEE REPLACEMENT - A GUIDELINE TO REDUCE POSTOPERATIVE LENGTH OF STAY
    WEINGARTEN, SR
    CONNER, L
    RIEDINGER, M
    ALTER, A
    BRIEN, W
    ELLRODT, G
    WESTERN JOURNAL OF MEDICINE, 1995, 163 (01): : 26 - 30
  • [6] INTRAOPERATIVE CONTROLS FOR BACTERIAL-CONTAMINATION DURING TOTAL KNEE REPLACEMENT
    RITTER, MA
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1989, 20 (01) : 49 - 53
  • [7] Do Knee Pain Phenotypes Have Different Risks of Total Knee Replacement?
    Pan, Feng
    Tian, Jing
    Munugoda, Ishanka P.
    Graves, Stephen
    Lorimer, Michelle
    Cicuttini, Flavia
    Jones, Graeme
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [8] Which knee replacement do the patients forget? Unicondylar or total knee arthroplasty
    Ates, Yalim
    Akdogan, Mutlu
    Atilla, Halis Atil
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2021, 55 (05) : 417 - 421
  • [9] Do diversion and improved donor arm disinfection reduce bacterial contamination in platelet concentrates?
    McDonald, CP
    Colvin, J
    Biggs, C
    Goodhand, K
    Harden, G
    McGuane, S
    TRANSFUSION, 2005, 45 (03) : 56A - 56A
  • [10] Embedded piezoelectrics for sensing and energy harvesting in total knee replacement units
    Wilson, Brooke E.
    Meneghini, R. Michael
    Anton, Steven R.
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2015, 2015, 9431