Effect of shielding the radioactivity outside the field of view on image quality in a dual head coincidence

被引:0
|
作者
Sossi, V [1 ]
Pointon, B [1 ]
Cohen, P [1 ]
Johnson, RR [1 ]
Ruth, TJ [1 ]
机构
[1] TRIUMF, UBC, Vancouver, BC V6T 2A3, Canada
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Limited count rate ability and open geometry make the image quality obtained from dual head cameras very sensitive to radioactivity outside the camera field of view. The spatial distribution of nan true events, scatter and randoms, originating from radioactivity outside the FOV was investigated. The image quality quantified with the noise equivalent count rate, improved by up to 58% as a consequence of shielding. Radioactivity in the first 10 cm outside the FOV was found to contribute most significantly to the detected events. A modular and easily movable patient body shield was designed.
引用
收藏
页码:1354 / 1358
页数:3
相关论文
共 50 条
  • [1] Effect of shielding the radioactivity outside the field of view on image quality in a dual head coincidence
    Sossi, V
    Pointon, B
    Cohen, P
    Johnson, RR
    Ruth, TJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1561 - 1566
  • [2] Effect of shielding on image contrast in a dual head coincidence camera.
    Sossi, V
    Cohen, P
    Hudkins, K
    Pointon, B
    Ruth, TJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 190P - 190P
  • [3] Effect of radioactivity outside the field of view on image quality of dedicated breast positron emission tomography: preliminary phantom and clinical studies
    Yoko Satoh
    Masamichi Imai
    Chihiro Ikegawa
    Kenji Hirata
    Norifumi Abo
    Mao Kusuzaki
    Noriko Oyama-Manabe
    Hiroshi Onishi
    Annals of Nuclear Medicine, 2022, 36 : 1010 - 1018
  • [4] Effect of radioactivity outside the field of view on image quality of dedicated breast positron emission tomography: preliminary phantom and clinical studies
    Satoh, Yoko
    Imai, Masamichi
    Ikegawa, Chihiro
    Hirata, Kenji
    Abo, Norifumi
    Kusuzaki, Mao
    Oyama-Manabe, Noriko
    Onishi, Hiroshi
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (12) : 1010 - 1018
  • [5] Image quality of dual-head coincidence cameras of the first and recent generation
    Schelper, LF
    Gosink, HJ
    Voss, P
    Meller, B
    Richter, E
    Baehre, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S404 - S404
  • [6] EFFECT OF SCATTER FROM RADIOACTIVITY OUTSIDE OF THE FIELD-OF-VIEW IN 3D PET
    SOSSI, V
    BARNEY, JS
    HARRISON, R
    RUTH, TJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1157 - 1161
  • [7] Effect of count rate on contrast in a dual head coincidence camera
    Sossi, V.
    Krzywinski, M.
    Cohen, P.
    Mankoff, D.A.
    Hudkins, K.
    DeRosario, J.
    Ruth, T.J.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1907 - 1911
  • [8] Effect of motion outside the field of view on functional MR
    Yetkin, FZ
    Haughton, VM
    Cox, RW
    Hyde, J
    Birn, RM
    Wong, EC
    Prost, R
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (06) : 1005 - 1009
  • [9] The effect of activity outside the field of view on image quality for a 3D LSO-based whole body PET/CT scanner
    Matheoud, R.
    Secco, C.
    Della Monica, P.
    Leva, L.
    Sacchetti, G.
    Inglese, E.
    Brambilla, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19): : 5861 - 5872
  • [10] Shielding to reject scatter from outside the field-of-view in infant PET scans.
    Ollinger, JM
    Powers, WJ
    Lich, LL
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1022 - 1022